Go to page of
Similar user manuals
-
Network Card
Honeywell UDC 6300
8 pages 0.46 mb -
Network Card
Honeywell 800-08115
4 pages 0.33 mb -
Network Card
Honeywell CONTROLBUS QS7800B
8 pages 0.83 mb -
Network Card
Honeywell DCP552 Mark II
247 pages 6.39 mb -
Network Card
Honeywell 50010425-501
1 pages 0.13 mb -
Network Card
Honeywell PRO-2200
16 pages 0.28 mb -
Network Card
Honeywell N-ANN-RLY
2 pages 0.09 mb -
Network Card
Honeywell HCE 60
56 pages 0.56 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell UMC800, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell UMC800 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Honeywell UMC800. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Honeywell UMC800 should contain:
- informations concerning technical data of Honeywell UMC800
- name of the manufacturer and a year of construction of the Honeywell UMC800 item
- rules of operation, control and maintenance of the Honeywell UMC800 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell UMC800 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell UMC800, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell UMC800.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell UMC800 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Sensing and Control UMC800 Contr oller Install ation and U ser Guide Doc. No.: 51-52-25- 61 Release: F Last Rev ision Date: 4/01[...]
-
Page 2
ii UMC800 Controller Installat ion and User Guide Release F 4/01 Notices and Trad emarks Copyright 2001 by Honeywell Release F April, 20 01 Warranty /Remedy Honeyw ell warrants goods of its manufa cture as being fr ee of defect ive materials and faulty w orkmanship. Cont act your local sales office f or warranty informat ion. If warrante d goods ar[...]
-
Page 3
Release F UMC800 Control l er I nstallation and User Guide iii 4/01 A bout Th is Doc ument Abstract This docum ent provides descri ptions and procedures for the inst allation, operation and maintenance of t he UMC800 Control ler hardware. References The follo wing list ide ntifies all docume nts t hat may be sources o f reference for material di sc[...]
-
Page 4
iv UMC800 Controller Installat ion and User Guide Release F 4/01 Symbol Defini tions The following table lists t hose s y mbols that may be used in this d o cument to denote certain conditio ns. Symbol Definition Thi s DA NGE R symbo l indic ates an im m inently ha zardous situati on, wh ich, if not a voided, w ill result in death o r serious injur[...]
-
Page 5
Release F UMC800 Control l er I nstallation and User Guide v 4/01 Contents Introduction ............................................................................................. 1 Purpose ........................................................................................................................ 1 UMC800 Contr oller ................[...]
-
Page 6
vi UMC800 Controller Inst allat ion and User Guide Release F 4/01 Maintenance ......................................................................................... 63 Overview .................................................................................................................... 63 Routine Maint ena nc e ...........................[...]
-
Page 7
Release F UMC800 Control l er I nstallation and User Guide vii 4/01 Tables Table 1 Controller plu g-in I/O module types ................................................................................... .............................6 Table 2 Commun ication port descriptions ..........................................................................[...]
-
Page 8
viii UMC800 Controller Inst allat i on and User Guide Releas e F 4/01 Figures Figure 1 UMC 800 components.................................................................................................... ................................. 3 Figure 2 UMC 800 controller hardw are ......................................................................[...]
-
Page 9
Introduction Purpose Release F UMC800 Control l er I nstallation and User Guide 1 4/01 Introductio n Purpose This Installation and U ser guide assists i n the installatio n, start up, operatio n, maintenance and troubles hooting of the UMC800 Controll er. The information in this guide is orga nized as follows: Topic Description Page UMC800 O vervie[...]
-
Page 10
Introduction UMC800 Control ler 2 UMC800 Controller Installation and User Guide Releas e F 4/01 UMC800 Controller The UMC800 is i ndustrial process control equ ip ment th at must be mounted. The w iring terminals mus t be enclosed within a pan el. CE Conformit y (Europe) This product is in conform ity with the protecti on requirements of t he follo[...]
-
Page 11
UMC800 O verview UMC800 D escription Release F UMC800 Control l er I nstallation and User Guide 3 4/01 UMC800 Overview UMC800 Description The Univ ersal Multiloop Cont roller (UMC800) is a m odular cont roller designed to addres s the analog and digit al control requi re ments of sm all unit processes . With up to 16 anal og control loops , four se[...]
-
Page 12
UMC800 O verview Feature Summary 4 UMC800 Controller Installation and User Guide Releas e F 4/01 through the C o nfiguration port allows rem ote acces s to the controller via the Control Builder and Us er Utility programs. This will e nable tr o uble shooting, configuratio n c hanges and firmware upgrade. The optional communicati o ns board adds tw[...]
-
Page 13
Equipment Ide ntification Controller Co mponents Release F UMC800 Control l er I nstallation and User Guide 5 4/01 Equipment Id entifica tion Controll er Components Enclosu re The UMC800 controller illus trated in Figure 2 consists of a single m etal e nclosure that houses the following controller co mponents: • Power supply module that plugs int[...]
-
Page 14
Equipment Ide ntification Controller Co mponents 6 UMC800 Controller Installation and User Guide Releas e F 4/01 I/O modules Eleven di fferent module ty pe s can be installed in the controller t o support both analog and digita l inputs and outpu t s of various types and signal lev els. T he signal ty p e and I/O capacity for each module type is in[...]
-
Page 15
Equipment Ide ntification Operator Interf ace Release F UMC800 Control l er I nstallation and User Guide 7 4/01 Operator Interface The UMC800 operator interf ace (Figure 3, Figure 4, an d Figure 5) provides a graphi c LCD display and a monoplaner key board to allo w operator acces s to all controller fun ctions. The operator interface becom es oper[...]
-
Page 16
Equipment Ide ntification Control Buil der 8 UMC800 Controller Installation and User Guide Releas e F 4/01 Con trol Bu ilder All controller and operator in terface configuration is perf or med using Control Builder software on a separate PC op erating with Windows TM 95 or Window s TM NT 4.0. All configuration is performed off-l ine (computer disco[...]
-
Page 17
Equipment Ide ntification Control Buil der Release F UMC800 Control l er I nstallation and User Guide 9 4/01 Complet ed configurations may also be s aved on 3.5" floppy disk an d loaded into the con troller and operator interf ace through an optional 3.5" floppy disk drive, eliminating the n eed for a direct connection of a PC to the cont[...]
-
Page 18
Equipment Ide ntification Serial Communi cation Ports 10 UMC800 Controller Installat ion and User Guide Release F 4/01 Serial Communicati on Por ts The controller contain s dedicated serial ports for extern al communications. These are described in Table 2. Table 2 Communication port descriptions Communication Port (on CPU Module) Description Confi[...]
-
Page 19
Pre-Installatio n Consideration s Introduction Release F UMC800 Control l er I nstallation and User Guide 11 4/01 Pre-Installation C onsidera tions Introduction Installation of the controller consists of mounting an d wiring th e controller according to the guidelines given in this section. T he controller is industrial control eq uipment that must[...]
-
Page 20
Pre-Installatio n Consideration s Introduction 12 UMC800 Controller Installat ion and User Guide Release F 4/01 Electrica l consid eration s The controller is cons idered “ op en eq uip ment ” per EN 61010-1, Safety Requirements for Electrical Equipmen t for Measurement , Control, and Laborat or y Us e, Part 1: General R equirements. Conf ormit[...]
-
Page 21
Pre-Installatio n Consideration s Introduction Release F UMC800 Control l er I nstallation and User Guide 13 4/01 Permissible wire bundling Table 4 sh o w s which wire funct ions should be bu ndled toget her. Table 4 Permissible w iring bundles Bundle No. Wire Functions 1 • Line power wiring • Earth ground w iring • Control relay output wirin[...]
-
Page 22
Pre-Installatio n Consideration s Introduction 14 UMC800 Controller Installat ion and User Guide Release F 4/01[...]
-
Page 23
Mounting and Wiring Site Preparation Release F UMC800 Control l er I nstallation and User Guide 15 4/01 Mounting an d Wiring Site Prepa ration The UMC800 mus t be mounted within an enclosure. Hardw are is provided to surf ace mount the cont roller to a panel or other su itable surface. Be sure that there is sufficient clearan ce for mounting th e c[...]
-
Page 24
Mounting and Wiring Mounting the C ontroller 16 UMC800 Controller Installat ion and User Guide Release F 4/01 Power requirements The standard s upply uses 100/240 V ac or Vdc input ran ges for its source. The in put requirem e nts are list ed in Table 5. In structions for wi ri ng the power supply are found in Table 5. Table 5 Power supply input re[...]
-
Page 25
Mounting and Wiring Mounting the C ontroller Release F UMC800 Control l er I nstallation and User Guide 17 4/01 Enclosure mounting dimensions 11.37 286.26 7.0 177.8 i nches Dimensions = ________ _ m illimeters 11.77 298. 96 13.02 7 330.8 9 3.013 76.53 0.25 6.35 NOTE: Allow 7.0 ” (178 mm) dept h to mounting dim ensions for con troller enclosur e a[...]
-
Page 26
Mounting and Wiring Plug-in M odule Locations 18 UMC800 Controller Installat ion and User Guide Release F 4/01 Plug-in M odule Locations Common backpl ane The controller backplan e provides common conn ectio ns for the pow er supply, CPU and I/O modules. All modules are inst al led into the backplane in their assigned s lot s designated by the cont[...]
-
Page 27
Mounting and Wiring Plug-in M odule Locations Release F UMC800 Control l er I nstallation and User Guide 19 4/01 OUT 4 + _ OUT 3 + _ OUT 2 + _ OUT 1 + _ 0-20 mA ! I/O Module PWA Ter m inal Bloc k Figure 10 I/O module PWA and terminal Table 6 I/O module identification Module Ty pe ID Number Terminal Block Color Part Number Analog Input (AI) 1 Black [...]
-
Page 28
Mounting and Wiring Plug-in M odule Locations 20 UMC800 Controller Installat ion and User Guide Release F 4/01 I/O module limits The controller backplane accom modates I/O module types, subject to the limitations as shown in Table 7. Slot Locations identify the allow able locatio ns in the controller for each I/O modu le t ype. Maximum Allowed desc[...]
-
Page 29
Mounting and Wiring Plug-in M odule Locations Release F UMC800 Control l er I nstallation and User Guide 21 4/01 Controller model number The controlle r model num ber specified on your purch ase order indicat es the I/O module t ypes and the assigned s lot locatio n of each I/O modu le present in the controller. The number fields that identify I/O [...]
-
Page 30
Mounting and Wiring Plug-in M odule Locations 22 UMC800 Controller Installat ion and User Guide Release F 4/01 Verify I/O module locations The table belo w outlines the step s for id entifying and reco r d ing the I/O module types in the controller. Step Action 1 Verify that the module types installed in t he controll er card slots ar e correct acc[...]
-
Page 31
Mounting and Wiring Signal Wiring Release F UMC800 Control l er I nstallation and User Guide 23 4/01 Signal Wiring I/O module wiring Termin al blocks are installe d to the front of th e I/O modules for conn ecting field devi ce wiring as shown in Figure 11. T erminal blocks are color coded and num bered to identify th e I/O module type. (See Table [...]
-
Page 32
Mounting and Wiring Signal Wiring 24 UMC800 Controller Installat ion and User Guide Release F 4/01 A nalog input / analog output fiel d w iring Shielded twisted pairs are recom mended (and required for C E approval) for analog in put (AI) and analog output ( AO) m odule field wiring . I f a cabinet shiel d termination point is not available, th e o[...]
-
Page 33
Mounting and Wiring Signal Wiring Release F UMC800 Control l er I nstallation and User Guide 25 4/01 A nalog inputs (module ID 1) A universal Analog Input modu le accepts a variety of input signals from field devices as su mmarized in Table 9. Figure 13 illustrate s the terminal blo c k con nections for the various inpu ts. See Sp ecifications sect[...]
-
Page 34
Mounting and Wiring Signal Wiring 26 UMC800 Controller Installat ion and User Guide Release F 4/01 Field wiring for one pH sensor input (module ID C) Figure 14 i ndicates the recomm e nded wiring for on e pH sensor input. N ote that two analog i nput channels are required, one for the pH sensor and one for temperature. Similar wiring ma y be used f[...]
-
Page 35
Mounting and Wiring Signal Wiring Release F UMC800 Control l er I nstallation and User Guide 27 4/01 A nalog outputs (module ID 2) The Anal o g Output ( AO) modul e provides four ou tputs at 0 mA to 20 mA (configurable for 4 m A to 20 mA or any span between 0 mA to 20 mA). Wh en not used for an analog output, an ou tp ut channel may be used to pow [...]
-
Page 36
Mounting and Wiring Signal Wiring 28 UMC800 Controller Installat ion and User Guide Release F 4/01 Digital inputs Three types of Digital Input (DI) modules accept four types of input signals. 1. Log ic I nput (Modul e ID 3 and B) 2. DC In put (Module ID 4) 3. AC In put (Module ID 5) 4. Puls e/Frequency Inpu t (Module ID D ) Each type i s described [...]
-
Page 37
Mounting and Wiring Signal Wiring Release F UMC800 Control l er I nstallation and User Guide 29 4/01 12 11 10 9 8 7 6 5 4 3 2 1 DI 6 DI 4 DI 3 DI 1 DI 5 DI 2 Mo dul e ID #3, 4, or 5 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 Module B Identifiable by 32 s crew s Each odd-numbered terminal is internally grounded. DI 1 DI 2 DI 7 DI 3 DI 4 DI 5 DI 6 D[...]
-
Page 38
Mounting and Wiring Signal Wiring 30 UMC800 Controller Installat ion and User Guide Release F 4/01 Digital outputs There are four ty pes o f Digital Output (DO) modules that provide three ty pe s of Off/On con trol. 1. Relay (alarm) outpu t (Modul e ID 6) 46190308- 503 2. DC ou tput (Module ID 7) 4 6190341- 501 3. AC ou tput (Module ID 8) 4 6190344[...]
-
Page 39
Mounting and Wiring Signal Wiring Release F UMC800 Control l er I nstallation and User Guide 31 4/01 The Digital Output module with relay outputs (M o d ule ID 6) contain jumpers to set t he de-energized state of the relay co ntacts. The relays are f ac tor y set to n or mally open (NO) for each outpu t on the relay alarm module, as shown in Figure[...]
-
Page 40
Mounting and Wiring Signal Wiring 32 UMC800 Controller Installat ion and User Guide Release F 4/01 Pulse input/frequency input module with digital outputs Figure 19 s hows the termin al block connections for Puls e/Frequency Input Module. See Specifications section for det ails on all I/O module s pecifications. ATTENTION 16 Point Dig ital Input mo[...]
-
Page 41
Mounting and Wiring Signal Wiring Release F UMC800 Control l er I nstallation and User Guide 33 4/01 Pulse input/frequency input jumpers The Pulse/Frequenc y Inp ut Module with Digital O utput s ( Module ID D) contain ju mper s to set the de- energized In put Filter Cuto ff Frequency. All four inpu ts are factor y set to 500 KHz as shown in Figure [...]
-
Page 42
Mounting and Wiring Signal Wiring 34 UMC800 Controller Installat ion and User Guide Release F 4/01 V supply Choose a suppl y that is co mpatible with t he environmental require ments of your applicatio n. T he supply voltag e must be within th e requirement of both t he transmitter an d the pulse input card. T ypi cally a low cost 12 Vdc un regulat[...]
-
Page 43
Mounting and Wiring Signal Wiring Release F UMC800 Control l er I nstallation and User Guide 35 4/01 Pulse frequency card outputs The pulse f requency card outpu ts are open collector drivers designed to dri ve a maximum of 100 mA . All Pulse F requency card digi tal outputs are opt ically isolated f ro m each oth er. The maximum supply voltage mus[...]
-
Page 44
Mounting and Wiring Wiring Com munication Li nks 36 UMC800 Controller Installat ion and User Guide Release F 4/01 Wiring Communi cation Li nks Serial communica tions ports The controlle r communicates th rough a number of serial ports. The C P U modu le contains tw o serial ports . One is an RS 232 con nection to a PC and another is dedicated for c[...]
-
Page 45
Mounting and Wiring Wiring Com munication Li nks Release F UMC800 Control l er I nstallation and User Guide 37 4/01 Table 10 Summary of communication link connections to controller Communication Link to . . . Link Ty pe From Controller Port Connect Cable To Port Reference Data PC or laptop (via Null M odem cable or via mode m) RS 232 CONFIGURATION [...]
-
Page 46
Mounting and Wiring Wiring Com munication Li nks 38 UMC800 Controller Installat ion and User Guide Release F 4/01 CONFIGURATION cable Table 12 Null modem cable construction PC Connector 9-Pin “D ” Female UMC8 00 9-Pin “D ” Male Pin Pin 2 3 5 4 6 7 8 2 3 5 4 6 7 8 Order part number - 51404755- 501[...]
-
Page 47
Mounting and Wiring Wiring Com munication Li nks Release F UMC800 Control l er I nstallation and User Guide 39 4/01 Installing fer rite clamp f or CE compliance This proced ure ensures that unwanted radio frequency noise is filter ed . It is required for CE co mpliance. Parts n eeded Part # Quantit y Description 047260 1 Ferrite cable cla mp s 0890[...]
-
Page 48
Mounting and Wiring Wiring Com munication Li nks 40 UMC800 Controller Installat ion and User Guide Release F 4/01 DISPLAY connec tor (to operator interface) The controller is conn ected to the operator interface through a 15-pin D-Type connector cable. On e cable end is connected to th e DISPLAY co nnector of the controller. The other en d connects[...]
-
Page 49
Mounting and Wiring Wiring Com munication Li nks Release F UMC800 Control l er I nstallation and User Guide 41 4/01 Connector location at the rear of the operator interface Connec tor Te rminal Wiring Signal Wire Termina l Name Color Numbe r RX- Black 1 RX+ W hite 2 RX Shd. Shield ----- 3 TX Shd. Shield --- TX- B lack 4 TX+ Red 5 Sig. Gnd Black ---[...]
-
Page 50
Mounting and Wiring Wiring Com munication Li nks 42 UMC800 Controller Installat ion and User Guide Release F 4/01 COMM A and B connectors (optional) The CPU module equipp ed with the optional co mmunicatio n board provides two additional RS 485 communi cations ports wi th Modbus RTU protocol support. COMM A port allows the UMC800 control ler to net[...]
-
Page 51
Mounting and Wiring Wiring Com munication Li nks Release F UMC800 Control l er I nstallation and User Guide 43 4/01 RS 485 seri al com municat ions When conn ecting the controll er to a RS 485 communi cation link (see Figu re 27), you must use te r minati o n resistors at each end of the link. The following cables with th e listed resistor values c[...]
-
Page 52
Mounting and Wiring Remo te Acce ss 44 UMC800 Controller Installat ion and User Guide Release F 4/01 Remote A ccess Overv iew Remote controller access v ia dial-up modem is available via the communication setup. An ex ter nal modem is requi red at the controlle r and is connected to th e standard RS232 conf iguration port (m arked “ CONFIGURATION[...]
-
Page 53
Mounting and Wiring Remo te Acce ss Release F UMC800 Control l er I nstallation and User Guide 45 4/01 Modem configuration Before connecting a modem to th e controller ’ s RS232 port (m arked “ C ONFIGU RATIO N ” ), the modem must be configured with the following settings: • Baud Rat e = 9600 • Parity = None • 1 stop bit • 8 data bits[...]
-
Page 54
Mounting and Wiring Remo te Acce ss 46 UMC800 Controller Installat ion and User Guide Release F 4/01 Modem con figuration examp les Belo w are procedures for settin g up the follo wing commercially available mode ms: • 3Com US Robotics 56K Data/Fax Ext ernal Modem • Zoom 56K D ualmode External Mode m • Best Data 56SX Data Fax External Modem ?[...]
-
Page 55
Mounting and Wiring Remo te Acce ss Release F UMC800 Control l er I nstallation and User Guide 47 4/01 Step Action 9 Set the modem switches t o the following: Switch Setting Position Function 1 ON DO W N Modem ignor es DTR (Ov erride) 2 OFF UP Verbal (word) resul ts 3 OFF UP Suppresses result c odes 4 ON DOWN Suppresses echo 5 OFF UP Modem answ ers[...]
-
Page 56
Mounting and Wiring Remo te Acce ss 48 UMC800 Controller Installat ion and User Guide Release F 4/01 Zoom 56K Dualmode External Modem Step Action 1 Connect the mo dem to a PC. If y our PC ’ s RS232 port has a 25-pin connector, us e a DB-25 male to DB-25 fe male RS232 ca ble. If your PC ’ s RS2 32 port has a 9-pi n connector, u se a DB-25 male t[...]
-
Page 57
Mounting and Wiring Remo te Acce ss Release F UMC800 Control l er I nstallation and User Guide 49 4/01 Best Data 56 SX Data F ax Ext ernal Modem Step Action 1 Connect the mo dem to a PC. If y our PC ’ s RS232 port has a 2- pin connector, use a DB-9 male to DB-25 female modem cable. If your PC ’ s RS232 p ort has a 9-pin c onnector, use a DB-9 m[...]
-
Page 58
Mounting and Wiring Remo te Acce ss 50 UMC800 Controller Installat ion and User Guide Release F 4/01 SixNet VT-M OD EM Industrial Exte rnal Modem Step Action 1 Connect the mo dem to a PC. If y our PC ’ s RS232 port has a 25 pi n connector, use a DB-9 male to DB-25 fe male modem cab le. If your PC ’ s RS232 port has a 9 pi n connector, use a DB-[...]
-
Page 59
Mounting and Wiring Power Supply W iring Release F UMC800 Control l er I nstallation and User Guide 51 4/01 Power Suppl y Wiring The power wi ring is connected to the power terminals of the power supply in accordan ce with accepted wiring practices an d is summarized in Table 14 shows t he terminal connections for the power wiring . F 3,15 A T 250V[...]
-
Page 60
Operation Po wer Up / P o wer Do wn 52 UMC800 Controller Installat ion and User Guide Release F 4/01 Operatio n Po wer Up / Po wer Do wn Pow er-up A sequence of ch ec ks are perform ed b y the con troller anytime power is applied to th e controller. These checks are a set of internal diagnostics that are completed in less than 10 s econds after pow[...]
-
Page 61
Operation Operational M odes and Contro ls Release F UMC800 Control l er I nstallation and User Guide 53 4/01 Operational Modes and Contr ols There are three operati onal modes def ined in the UMC800 to prov ide safe operatin g environments for users to implement chang es and perform tasks on t he controller and operator interf ace. 1. PROGRAM Mode[...]
-
Page 62
Operation Operational M odes and Contro ls 54 UMC800 Controller Installat ion and User Guide Release F 4/01 2. From the Operator In terface. Mode chang e s can be made from SET MODE display or the Calibrate AI and AO di splays of the operator interf ace with certain restrictions. Wh en the manual s witch is set to PROGRAM, you cannot change the m o[...]
-
Page 63
Operation Operational M odes and Contro ls Release F UMC800 Control l er I nstallation and User Guide 55 4/01 Table 15 Co ntroll er mode sw itch su mmary Controller Mode Manu al Switch setting Mode Control through the Configuration Port or O perator Interface RUN Unrestricte d mode change s. The mode selected via the C onfiguration port or operator[...]
-
Page 64
Operation File Downloa ding 56 UMC800 Controller Installat ion and User Guide Release F 4/01 File Downlo ading Downloading configu ration files, recipes and other files to the cont roller can be acco mplished two ways: 1. Download from a P C or other device connected the C onfiguration port (serial port) of the controller. 2. Using the operator in [...]
-
Page 65
Operation Code Dow nload Release F UMC800 Control l er I nstallation and User Guide 57 4/01 Download v ia CONFIGURA T ION port A downloading tool in the control builder so f t ware can be used to do wnload configuration files to the controller. T he downloading tool first verifies that a valid con figuration file exists for the controller . Next, a[...]
-
Page 66
Operation W arm Start / Cold St art 58 UMC800 Controller Installat ion and User Guide Release F 4/01 Warm Start / Cold Start Housekeeping and diagnosti c routines are perform ed during power u p sequence of the con troller and prior to the controller m icroprocessor starting n or mal scan proces sing. During this sequence all logic outputs are OFF [...]
-
Page 67
Operation Status Indica tors Release F UMC800 Control l er I nstallation and User Guide 59 4/01 Number of analog input cards Time to complete one full scan (in milliseconds) 8 1700 9 1900 10 2100 11 2300 12 2500 13 2700 14 2900 15 3100 16 3300 Status Indicator s Status LEDs Four L ED s on the CPU modul e (shown in Figure 30) i ndicate the operati n[...]
-
Page 68
Operation Status Indica tors 60 UMC800 Controller Installat ion and User Guide Release F 4/01 Controll er Status Indicators CPU Module _ 100 - 24 0 V ~ 50 / 6 0 Hz 100 VA MAX. POWER Lo BA T FORCE RUN DISPL AY BA T CONFIG URATION OFFLINE RUN PROGR AM Re pl ac e ba tt ery wit h Tadi ran T L5 10 1/ S o n ly . Us e of a n other ba ttery m ay pre se nt [...]
-
Page 69
Operation RS 485 Port C onfiguration (Com munication Boar d Option) Release F UMC800 Control l er I nstallation and User Guide 61 4/01 RS 485 Port Configuration (Communication Board Option) COMM A a nd B ports UMC cont rollers equipped wit h the optional comm unications board featu re t wo RS 485 serial communi cations ports (COMM A and COMM B) on [...]
-
Page 70
Operation RS 485 Port C onfiguration (Com munication Boar d Option) 62 UMC800 Controller Installat ion and User Guide Release F 4/01[...]
-
Page 71
Maintenanc e Overvie w Release F UMC800 Control l er I nstallation and User Guide 63 4/01 Maintenance Over vi ew This section covers procedures in the maintenance, calibration and replacem ent o f the cont roller and its compon ents. Maintenance to the controller consists o f the following procedures: • Routi ne main te na nc e • Calibration of[...]
-
Page 72
Maintenanc e Routine M aintenance 64 UMC800 Controller Installat ion and User Guide Release F 4/01 Routine M aintenance Controller maintenance Normal routin e mainte nance of the controller is not necessary ot her than a periodic physical ins pectio n of the con troller enclosure an d wiring for any signs of deterioration or dus t and dirt. Battery[...]
-
Page 73
Maintenanc e Controller Cal ibration Release F UMC800 Control l er I nstallation and User Guide 65 4/01 Con troller C alibr ation ATTENTION All Analog Inpu t (AI) and Analog O utput (AO) modules a re factory cali brated to 0.1% a ccuracy. If this accu racy is suffici ent for your appl ications, t here is not need to recalibrate t he modules. If gre[...]
-
Page 74
Maintenanc e Controller Cal ibration 66 UMC800 Controller Installat ion and User Guide Release F 4/01 Factor y calibrat ion Factory calibration of controller components is perform ed before shipment to 0.1% accuracy. C alibration values are containe d in a number of the con troller co mponents , namely: the CPU, Backplane, and AI an d AO m odules. [...]
-
Page 75
Maintenanc e Controller Cal ibration Release F UMC800 Control l er I nstallation and User Guide 67 4/01 Field calibration Field calibration of controller co mponents is li mited to AI modules and AO modules. Individual channels of the m od ules can be calibrated at 0% an d 100% of thei r range. Individual ch a nnels can be cali brated at a singl e [...]
-
Page 76
Maintenanc e Controller Cal ibration 68 UMC800 Controller Installat ion and User Guide Release F 4/01 12 11 10 9 8 7 6 5 4 3 2 1 1 Chan nel 4 Channe l 3 Chann el 2 Channe l 1 + - RTD + - RTD + - RTD + - RTD + - Thermo couple Inp ut T/C, mV, V Ground Terminal + - RTD RTD Input (3 w ires) Gro und Te rminal + - Current Input m A * A 250 o hm resisto r[...]
-
Page 77
Maintenanc e Controller Cal ibration Release F UMC800 Control l er I nstallation and User Guide 69 4/01 ST1 OU T 4 + _ OU T 3 + _ OU T 2 + _ OU T 1 + _ 0-20mA ! Wire Jum pe r S T 1 Anal og Outpu t Modu le Figure 34 AO module jumper ST1[...]
-
Page 78
Maintenanc e Replacement Pro cedures 70 UMC800 Controller Installat ion and User Guide Release F 4/01 Replacement Procedures The following tables outline the procedu res for replacement of the con troller co mpon e nts. Field replacement is limited to the Printed Wiring Asse mbl y (PWA) level. Use Figure 35 to locate controller compon ents for repl[...]
-
Page 79
Maintenanc e Replacement Pro cedures Release F UMC800 Control l er I nstallation and User Guide 71 4/01 CAUTION TO PRESERVE THE CONTROLLER CONFIGURATION PRIOR TO PERFOR MING ANY REPLACEMENT PROCEDURES OR REMOVING POW ER TO THE CONTROLLER: • Be certain that the LoBatt LED is O FF. (MEMORY – LO W BATT ERY diagnostic is not active.) • Force a co[...]
-
Page 80
Maintenanc e Replacement Pro cedures 72 UMC800 Controller Installat ion and User Guide Release F 4/01 Replacing the power supply fuse The power supply input circuit is protected with a fuse. Use the steps in th e table belo w to replace th e fuse on th e po w er supply modul e. Step Act io n 1 Remove power from the contro ller. 2 Locate the fu se h[...]
-
Page 81
Maintenanc e Replacement Pro cedures Release F UMC800 Control l er I nstallation and User Guide 73 4/01 Replacing the battery A lithium battery is used as a keep alive voltage for the volatile memory (RAM) that contains the co ntroller configurati on. The battery is inst alled in a compartment on the CPU module. Follow t he steps in the table below[...]
-
Page 82
Maintenanc e Replacement Pro cedures 74 UMC800 Controller Installat ion and User Guide Release F 4/01 Replacing I/O modules If any I/O m odules need to be replaced, follow t he steps in the table below . Step Action 1 Remove power from controller. 2 Remove fro nt cover by loose ning the two screw s at the top of the enclosure . 3 Locate the I/O mod[...]
-
Page 83
Maintenanc e Replacement Pro cedures Release F UMC800 Control l er I nstallation and User Guide 75 4/01 12 11 10 9 8 7 6 5 4 3 2 1 2 Locks Field W i ring Terminal s Locks I/O Module Identifi cation Figure 37 I/O module terminal blocks (not shown: 16 point DI) Replacing the CPU module Follow the steps in the table below for replacement of t he CPU m[...]
-
Page 84
Maintenanc e Replacement Pro cedures 76 UMC800 Controller Installat ion and User Guide Release F 4/01 Replacing the power supply module Step Action 1 Remove power from controller. 2 Disconne ct power w iring from power supply terminals. 3 Remove fro nt cover by loose ning the two screw s at the top o f the enclosure . 4 Remove five screws on th e f[...]
-
Page 85
Maintenanc e Replacement Pro cedures Release F UMC800 Control l er I nstallation and User Guide 77 4/01 Replacing the backplane Step Action 1 Remove power from controller. 2 Disconne ct power w iring from power supply terminals. 3 Remove fro nt cover by loose ning the two screw s at the top o f the enclosure . 4 Remove five screws on th e front of [...]
-
Page 86
Maintenanc e Replacement Pro cedures 78 UMC800 Controller Installat ion and User Guide Release F 4/01 Step Action 18 Reconnect power wiring to proper terminals on power supply as show n. Hot Neutra l Grou nd F 3,15 A T 250V L1 L2 / N 19 Replace front cover and secure with two screw s. 20 Restore pow er to controller. 21 Verify config uration. Perfo[...]
-
Page 87
Diagnosti cs and Tr ou ble sho otin g Overvie w Release F UMC800 Control l er I nstallation and User Guide 79 4/01 Diagnostics and Trou bleshoo ting Over vi ew This section pro vides d iagnostic and tro ubleshooting infor mation to help in evaluati ng controller op erating statu s, di agno sing fa ul t co nd itio ns a nd ta ki ng a ctio ns to co rr[...]
-
Page 88
Diagnosti cs and Tr ou ble sho otin g Controller Dia gnostics 80 UMC800 Controller Installat ion and User Guide Release F 4/01 Controller status LEDs Status indicators on t he controller consist of four LEDs that indicate g ood and fault conditions in the controller. These L EDs indicate controller status and help to aid trou bleshooting when the o[...]
-
Page 89
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing Release F UMC800 Control l er I nstallation and User Guide 81 4/01 Fault Detection and Tr oublecl e ar ing Interpreting t he controller st atus and deter mining i f any corrective action is necessary can be done by referring to Table 20 and T able 21 . Actions to clear faul[...]
-
Page 90
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing 82 UMC800 Controller Installat ion and User Guide Release F 4/01 Controller Diagnostic Summary (In the User Ut ility and Oper ator Interface) Controller LED on CPU Fault Detection / Troubleclearing Menu Item Status Possible Cause Controller Action User A ction SYSTEM TASK F[...]
-
Page 91
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing Release F UMC800 Control l er I nstallation and User Guide 83 4/01 Controller Diagnostic Summary (In the User Ut ility and Oper ator Interface) Controller LED on CPU Fault Detection / Troubleclearing Menu Item Status Possible Cause Controller Action User A ction CPU ADDRESS[...]
-
Page 92
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing 84 UMC800 Controller Installat ion and User Guide Release F 4/01 Controller Diagnostic Summary (In the User Ut ility and Oper ator Interface) Controller LED on CPU Fault Detection / Troubleclearing Menu Item Status Possible Cause Controller Action User A ction CPU SPURIOUS [...]
-
Page 93
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing Release F UMC800 Control l er I nstallation and User Guide 85 4/01 Controller Diagnostic Summary (In the User Ut ility and Oper ator Interface) Controller LED on CPU Fault Detection / Troubleclearing Menu Item Status Possible Cause Controller Action User A ction RTC BATTERY[...]
-
Page 94
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing 86 UMC800 Controller Installat ion and User Guide Release F 4/01 Controller Diagnostic Summary (In the User Ut ility and Oper ator Interface) Controller LED on CPU Fault Detection / Troubleclearing Menu Item Status Possible Cause Controller Action User A ction COMM A GOOD ?[...]
-
Page 95
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing Release F UMC800 Control l er I nstallation and User Guide 87 4/01 Fault detection and tr ouble clearing Table 21 des cribes the status messages that appear on t he I/O Module Diagn ostics displays i n the user utility and operator interface, as well as the status indicatio[...]
-
Page 96
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing 88 UMC800 Controller Installat ion and User Guide Release F 4/01 I/O Module Diagnostics (In The User Ut ility and Operator Interf ace) Controller LED on CPU Fault Detection / Troubleclearing Menu Item Status Possibl e Cause Controller Action User A ction MODULE 1 through MO[...]
-
Page 97
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing Release F UMC800 Control l er I nstallation and User Guide 89 4/01 Modem troubleshooting Control ler modem problem s will ty picall y show one of tw o symptoms. • The modem does not answ er, or • the modem answers but do es not establis h co mmunications. Table 22 Contr[...]
-
Page 98
Diagnosti cs and Tr ou ble sho otin g Fault Detec tion and Trouble clearing 90 UMC800 Controller Installat ion and User Guide Release F 4/01[...]
-
Page 99
Parts L ist UMC800 Control ler Release F UMC800 Control l er I nstallation and User Guide 91 4/01 Parts List UMC800 Controller If you requ ire replacement or spare parts for the UMC controller, you can order them b y referring to th e tabl e be low and co nt acti ng your H o ne ywe l l rep re s e ntati ve. Replacement parts Part Descriptio n Part N[...]
-
Page 100
Parts L ist UMC800 Control ler 92 UMC800 Controller Installat ion and User Guide Release F 4/01 Part Descriptio n Part Number I/O Red T erminal Block 46190204- 501 Controller Fu se for 100-240 V supp ly (1 each) 46182886- 002 Controller Fuse for 24 V supply (1 each) Grommet Kit (P ower Terminal C over, Grommets (16) 51404796- 501 Shield T erminatio[...]
-
Page 101
Release E UMC800 Controll er I nstallation and User Guide 93 4/01 Specifications Introduction The following tables contain electrical, phy sical, safety and perform a nce specifications for the UMC800 controll er. Controll er Desi gn Parameter Description Controller CPU w ith two serial commun ication ports,* power supply , and backplan e assembly.[...]
-
Page 102
Specificatio ns I/O M odule Configuration 94 UMC800 Controller Installat ion and User Guide Release F 4/01 Component Parameter Description Accuracy (at r eference conditio ns) Factory configur ed accuracy = ± 0.1 % of range Cold junct ion accuracy = ± 0. 5 ° C Field calibr ation accur acy = ± 0.05 % of range Reference cond iti ons : Temperatur [...]
-
Page 103
Specificatio ns I/O M odule Configuration Release F UMC800 Control l er I nstallation and User Guide 95 4/01 Component Parameter Description Inputs per Module 6 (ID 3) or 16 (ID B) dry contact Logic Inputs (Module ID 3 and B) Switching Vo ltage 5 Vdc Switching Curr ent 5 mA Digital Outputs AC Outputs (Module ID 8) DC Outputs (Module ID 7) Outputs p[...]
-
Page 104
Specificatio ns I/O M odule Configuration 96 UMC800 Controller Installat ion and User Guide Release F 4/01 Component Parameter Description Pulse/Frequency Inputs with Digital Outputs Input 1 to 4 Voltage Level s Logic Input H igh Vih: 3.0 Vdc Logic Input L ow Vil: 1.0 Vdc Absolute Max : 27 Vdc Absolute M in: 0.0 Vdc Digital Outpu t (Open Collect or[...]
-
Page 105
Specificatio ns Design Release F UMC800 Control l er I nstallation and User Guide 97 4/01 Design Parameter Description Scan Rat e 1 AI modul e – (1 to 4 analo g inputs): 333 milliseconds 2 AI modules – (5 to 8 analog inputs): 500 mi lli se cond s 3 AI modules – (9 to 12 analog inputs): 70 0 milliseconds 4 AI modules – (13 to 16 analog input[...]
-
Page 106
Specificatio ns Design 98 UMC800 Controller Installat ion and User Guide Release F 4/01 Parameter Description Sy stem Interconnections Operator Interface (DISP LAY) Maxim um Distance Betwee n Controller File a nd Operator Interf ace: 50 feet Cable Type : 15 conductor, shield ed Cable term ination: 15-pin “ D ” connect or at the control ler end;[...]
-
Page 107
Specificatio ns Environmenta l and Operating C onditions Release F UMC800 Control l er I nstallation and User Guide 99 4/01 Environmental and Operating Conditi ons Parameter Reference Rated Extreme Transportation and Storage Ambient Temp. ° F ° C 77 ± 5 25 ± 3 32 to 131 0 to 55 32 to 140 0 to 60 – 40 to 151 – 40 to 66 Ambient Relative Humid[...]
-
Page 108
Specificatio ns PV Inputs 100 UMC800 Controller Installat ion and User Guide Release F 4/01 PV Inputs Range Standard ° F ° C Thermocouples J – 58 to 302 32 to 752 – 328 to 1598 – 50 to 150 0 to 400 – 200 to 870 IEC 584-1 (IT S90) IEC 584-1 (IT S90) IEC 584-1 (IT S90) L – 58 to 302 32 to 752 – 328 to 1598 – 50 to 150 0 to 400 – 200[...]
-
Page 109
Specificatio ns PV Inputs Release F UMC800 Control l er I nstallation and User Guide 101 4/01 Range Standard ° F ° C RTD/Ohms Pt 100 at 0 ° C – 130 to 464 – 58 to 302 32 to 212** 32 to 392 32 to 752 – 328 to 1472 – 90 to 240 – 50 to 150 0 to 100** 0 to 200 0 to 400 – 200 to 800 IEC 751-1986 IEC 751-1986 IEC 751-1986 IEC 751-1986 IEC [...]
-
Page 110
Specificatio ns PV Inputs 102 UMC800 Controller Installat ion and User Guide Release F 4/01[...]
-
Page 111
Index Release F UMC800 Controller Ins t al l at ion and User Guide 103 4/01 Index —A— Ambient Temperature, 11 analog input scan rate, 58 Ana log Input wir in g, 25 Ana log Output wir in g, 27 —B— Backplane, 18 replacement, 77 Battery Replacement, 64 —C— Cabling COMM A and B port, 42 Config uration port, 37 Display port, 40 Calibration, [...]
-
Page 112
Index 104 UMC800 Controller Ins tallat i on and Us er Guide Release F 4/01 —O— Off line mode, 53 Operating conditions, 99 Operationa l modes, 53 —P, Q— Par t Nu mbe rs , 91 Pow er , 11 Power C onsumption, 11 POW ER LED , 59 powe r supply replacement, 76 Power s upply option, 16 Pre-installation considiera tions, 11 Program mode, 53 —R— [...]
-
Page 113
SIKKERH ESKRAV DA 2I-6048 ! For at u ndgå elek trisk stø d m ed mulighed f or per sonsk ade, sk al alle sikk erhedsbes temm elser i de nne m anual f ølges nøj e. Dette s ymbol ad varer br ugeren om en po tentie l berør ingsfar e, såfr em t der kan være adgang t il den l ivsfarli ge netspæ nding. Besk yttende jor dterm inal. Ter m inalen er [...]
-
Page 114
VEILIGHEIDSVER EISTEN DU2I-6048 ! Ter verminder ing van het ge vaar v an elek trisc he schok ken die lich am elijk letsel k unnen veroor zaken, d ient u alle vei lighei dsaanwij zing en in dit dok um ent te volg en. Dit symbo ol waars chuw t de gebr uiker voor een potent ieel sc hok gevaar wa nneer toegang bes taat to t onderde len d ie ond er geva[...]
-
Page 115
TURVALLISUUSMÄÄRÄYKSET FI2I-6048 ! Noudata t ämän ohj een kaik k ia turvaohje ita vältt ääk sesi sähk ötapaturm an vaar aa. Täm ä merkk i varoittaa k äyttäjää sä hk öiskun va arasta pa ik assa, m iss ä voi ko skettaa vaaral lisia j ännitte itä. Suojam aali iti n. Kytk e m aadoits johd in tähän li itt im een. • J os laitetta[...]
-
Page 116
CONSIGNES DE SECURITE FR2 I -6 048 ! Pour ré duire to ut risq ue de déc harge él ectriq ue qui pourr ait prov oquer un e lésio n corporel le, resp ectez to utes les consi gnes de s écurité d e cette docum entation. Ce symbo le avertit l'util isateur d'un ris que élec trique potent iel lors qu'il pe ut avo ir accès à des él?[...]
-
Page 117
SICHERHEITSHINWEISE GE2I-6048 Befolg en Sie a lle S icherh eitshin weise in dies en Unterl agen, um das Ris iko e ines Strom s c hlags zu verri nger n, der zu Körp er v erlet zu ng führ e n k ann. Dieses S ymbol war nt den Benut zer vor e ventueller Berührun gsgef ahr, wo lebensgef ähr l iche Sp ann ung en zugän gl ic h sein können. Schützen[...]
-
Page 118
¦µ¦®¹¬¸ª®¸ ¦¸»¦°ª®¦¸ GR2I-6048 ! . . . • . • ?[...]
-
Page 119
NORME DI SICUREZZA IT2I-6048 ! Per ridur re i r ischi d i scaric he elettr iche c he potre bber o causare alle persone , seguir e tutte le precau zi on i circ a la sicure zza indic ate in ques t a doc um enta zione. Questo sim bolo avverte del p erico lo di sc ossa el ettrica nelle ar ee i n cui so no acc essibi li conduttor i sotto te nsione. Term[...]
-
Page 120
SIKKERHETSKRAV NO2I-6048 ! Følg all e retnin gslinj ene i de tte dok um entet, slik at du redus erer ris ik oen for elektr isk støt og m ulige pers onsk ader. Dette s ymbolet adv arer bruk eren om tilgj engeli ge term inaler med f arlige spenning er og en potens iell f are for elek trisk støt . Jordings term inal. k abelen f or j ording a v syst[...]
-
Page 121
INSTRUÇÕES DE SEGURA NÇ A PO2I-6048 ! Para redu zir o risco de choq ue eléctric o qu e pode ca usar da nos cor porais, s eguir to das as norm as de s egurança co ntidas n esta d ocum entação. Este sím bolo a visa o u tilizad or sobre um eventual per igo de choqu e quan do são acess íveis vo ltagens sob tens ão p erigos as. Term inal de p[...]
-
Page 122
NORMAS DE SEGURIDAD SP2I-6048 ! Para re ducir el r iesgo de choqu e eléc trico el cual podría c ausar l esiones p ersona les, seguir t odas las indic aciones de este docum ento. Este sím bolo pre vien e al usuar io de u n ries go pote ncial d e descar ga cuan do se puede acceder a c orrientes de t ensión p eligros as. Term inal de tierr a de pr[...]
-
Page 123
SÄKERHETSFÖRESKRIFTER SW2I-6048 ! För att red ucera r isker na av elek trisk a choc ker som k an orsak a personsk ador, f ölj alla säk erhetsför eskr ifter i denna dok um entation. Denna s ymbol varnar an vändar en f ör risk för elc hock vid tillf ällig åtk oms t av spännings förand e del. Anslutni ng av s k yddsjord. Avse dd för ansl[...]
-
Page 124
[...]
-
Page 125
HSM8 HONEYWELL SERVICE CENTERS A RGENTINA BULGA RIA GERMA NY HONEYW ELL S.A.I.C. BELGRANO 1156 BUENOS AIRES ARGENTINA Tel. : 54 1 383 9290 HONEYW ELL EOOD 14, Iskarsko Chausse POB 79 BG- 1592 Sofia BULGARIA Tel : 359-791512/ 794027/ 792198 HONEYW ELL AG Kaiserleistrasse 39 D-63067 OFFENBACH GERMANY Tel. : 49 69 80 640 A SIA PACIFIC CA NAD A HUNGARY[...]
-
Page 126
HSM8 HONEYWELL SERVICE CENTERS NORWA Y REPUBLIC OF SOUTH A FRICA SWEDEN HONEYW ELL A/S Askerveien 61 PO Box 263 N-1371 ASKER NORW AY Tel. : 47 66 76 20 00 HONEYW ELL Southern Africa PO BOX 138 Milnerton 7435 REPUBLIC OF SOUTH AFRICA Tel. : 27 11 805 12 01 HONEYW ELL A.B. S-127 86 Skarholmen STOCKHOLM SW EDEN Tel. : 46 8 775 55 00 POLA ND ROMA NIA S[...]
-
Page 127
[...]
-
Page 128
Sensi ng and Co nt rol Honey we ll 11 Wes t Spring Stree t Freepor t, IL 61032 51-52-25-61F 0401 Printed in USA www. honey w ell.com/sensing[...]