Go to page of
Similar user manuals
-
Server
HP (Hewlett-Packard) DA - 13716
22 pages 1.84 mb -
Server
HP (Hewlett-Packard) TC4100
121 pages 2.22 mb -
Server
HP (Hewlett-Packard) ProLiant Plus
11 pages 2.88 mb -
Server
HP (Hewlett-Packard) LXR 8000
95 pages 1.5 mb -
Server
HP (Hewlett-Packard) HPO-645
6 pages 0.17 mb -
Server
HP (Hewlett-Packard) ML330 G6
129 pages 4.07 mb -
Server
HP (Hewlett-Packard) AD117-9003A-ED3
177 pages 11.54 mb -
Server
HP (Hewlett-Packard) DL380
51 pages 1.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of HP (Hewlett-Packard) ESXi 5.0 U1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of HP (Hewlett-Packard) ESXi 5.0 U1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of HP (Hewlett-Packard) ESXi 5.0 U1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of HP (Hewlett-Packard) ESXi 5.0 U1 should contain:
- informations concerning technical data of HP (Hewlett-Packard) ESXi 5.0 U1
- name of the manufacturer and a year of construction of the HP (Hewlett-Packard) ESXi 5.0 U1 item
- rules of operation, control and maintenance of the HP (Hewlett-Packard) ESXi 5.0 U1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of HP (Hewlett-Packard) ESXi 5.0 U1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of HP (Hewlett-Packard) ESXi 5.0 U1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the HP (Hewlett-Packard) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of HP (Hewlett-Packard) ESXi 5.0 U1.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the HP (Hewlett-Packard) ESXi 5.0 U1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
HP VMw ar e Utiliti es U ser Gui de VMw ar e E SX i 5 . 0 U1 f or Mar c h 20 1 2 HP P ar t Number : 6 7 05 5 7 -002 P ublished: Marc h 20 1 2 E dition: 1[...]
-
Page 2
© Cop yr ight 200 7 , 20 1 2 Hewlett-P ackar d Dev elopment Co mpany , L.P . Conf idential co mputer softw are . V alid licens e fr om HP requir ed for po ssessi on, us e or copy ing. C onsistent w ith F AR 1 2.2 1 1 and 1 2 .2 1 2 , Commer ci al Compu ter Softwar e , Computer S oftwar e Documentati on, and T echnical Data f or Commer ci al Items [...]
-
Page 3
C ont ents 1 Intr oducti on...............................................................................................4 Installing o ffline bundles on an E SXi 5 .0 and u pdates hos t using vSpher e CLI 5 .0 e sxc li utility.............4 Pr er equisites ...........................................................................................[...]
-
Page 4
1 Intr oducti on This s ectio n pro vide s infor mation abo ut the utilities su pported on VMwar e ESX i 5. 0 and updates. The f ollo w ing utilities ar e supported on VMwar e E SXi 5 .0 and updat es host: • HP ONCFG — C ommand line utility used fo r obtaining and setting Pr oL iant iL O confi gur ations . • HPBOO T CFG — C ommand line util[...]
-
Page 5
HP off ers suppo r t fo r the iL O 2 , iL O 3 and iL O 4 featur es a vailable on Pr oLi ant serve rs w ith the HPONCFG utility . HPONCFG is an online conf igur ation t ool used to s et up and r econfi gure iL O 2 , iL O3 and iL O 4 w ithout r equir ing a r eboot of the serv er oper ating sy ste m. T he utility runs in a command-line mode and mus t [...]
-
Page 6
T abl e 2 hponcfg retur n codes (contin ued) Meaning V alue The iL O flash is still in pr ogress . 3 The s cr ipt is unable to cr eate an output f ile . 2 5 5 If the sc ript its elf fails , err ors ar e repo r ted in the log f ile cr eated b y HPONCFG . HP ONCFG co mmand file con tents The hponcfg co mmand can be used to perf orm the f ollo wing t [...]
-
Page 7
USER_NAME="Administrator" USER_LOGIN="Administrator" PASSWORD=""> </ADD_USER> <ADD_USER USER_NAME="Landy9" USER_LOGIN="mandy9" PASSWORD=""> </ADD_USER> <RESET_RIB VALUE="Y"/> </HPONCFG> F or sec urity rea sons, the u ser pass wor ds are not r etur[...]
-
Page 8
</USER_INFO> </LOGIN> </RIBCL> The s pec ified u ser w ill be added to the de vi ce . HP ONCFG co mmand-line ex amples This s ectio n pro vide s sample e xample s to run the utility . T abl e 3 hponcfg command-line e xamples Description Command-line argument This ar gument displa ys he lp infor mation. hponcfg -h This ar gument r [...]
-
Page 9
T abl e 4 hpbootcfg Command L ine Arguments (con tinued) Function Argument Sets R OM-Based Se tup Utility (RBS U) as the boot dev ice f or the cur re nt boot -R Sets P XE client as the boo t dev ice for the c urr ent boot -P Sets r emote conf igur ation as the boot de vi ce for the c urr ent boot -r Sets r emote dial o ut as the boot dev ice for th[...]
-
Page 10
T abl e 6 hpbootcfg command-line e x amples Description Command-line argument This ar gument displa ys he lp infor mation. /opt/hp/tools/hpbootcfg -h This ar gument se ts the default v alues. /opt/hp/tools/hpbootcfg -D HP A CUCLI utility The HPACUCLI u tilit y supports HP Pr oL iant 300/5 00/7 00 and Blade server s with in tegrat ed SmartArr ay con[...]
-
Page 11
Ex ample 1 This e xample sho ws the inf ormati on about all the SmartAr ra y contr oller on the s erver . esxcli – server= ” servername or IP ” – user= ” username ” – password= ” root password ” hpacucli cmd – q hpacucli cmd -q “ controller all show status ” The f ollo w ing output is displa y ed: Smart Array P212 in Slot 9 [...]
-
Page 12
Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 256 KB Full Stripe Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001CB65083D63C5E781ABF65 Disk Name: vmhba2:C0:T0:L1 Mount Points: None Logical Drive Label: A00D1AF35001438013A25C90F0BA Mirror Group 0[...]
-
Page 13
Firmware Revision: HPDE Serial Number: 6SD3FK4A0000B145J6JK Model: HP EG0146FAWHU Current Temperature (C): 37 Maximum Temperature (C): 48 PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown ... The se e xample s are n ot inclusi ve of all the capa bilities o f the HPACUCLI command. C ommands and options f or additio nal operati ons using the HPACUCLI [...]
-
Page 14
2 Suppo r t and other r es our ces This c hapter pr ov ides inf ormation a bout the contac t details and r efe rence doc uments. C ontac ting HP This s ectio n pro vide s infor mation abo ut the pre req uisites to be v erif ied befo re con tacting HP and mechanism su pported by the or ganiz ation f or shar ing the feedbac k. Bef or e yo u contac t [...]
-
Page 15
Ne w and c hanged inf ormati on in this editi on Cur r ent edition o f the docume nt pr ov ides inf ormation a bout the HPACUCLI utility supported on the ESXi v ersio n 5 .0 and u pdates platfo rm . R elated inf or matio n F ollo w ing docume nts and web sites pr o vi de relat ed infor mation: Doc uments F ollo w ing docume nts are su pported for t[...]
-
Page 16
W ARNING A w arning calls attenti on to important inf ormati on that if not unders tood or fo llow ed will r esult in per sonal inj ur y or nonr eco ver able sy stem pr oblems. CA UTION A cauti on calls attentio n to important inf ormati on that if not unders tood or f ollow ed will r esult in data lo ss, dat a corr uption , or damage to har d war [...]
-
Page 17
Inde x D doc ument r elated doc umentation , 1 5 R r elated doc umentation , 1 5 1 7[...]