hussman IGUP-RED-0309 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of hussman IGUP-RED-0309, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of hussman IGUP-RED-0309 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of hussman IGUP-RED-0309. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of hussman IGUP-RED-0309 should contain:
- informations concerning technical data of hussman IGUP-RED-0309
- name of the manufacturer and a year of construction of the hussman IGUP-RED-0309 item
- rules of operation, control and maintenance of the hussman IGUP-RED-0309 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of hussman IGUP-RED-0309 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of hussman IGUP-RED-0309, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the hussman service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of hussman IGUP-RED-0309.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the hussman IGUP-RED-0309 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    /Chino RED Refrigerated End Displa y Re v .0309 Installation & Operation Manual RED Refrigerated End Displa y p/n IGUP-RED-0309 INST ALLA TION & O PE RA T IO N GUIDE[...]

  • Page 2

    IGUP-RED-0309 2 /Chino A publication of Hussmann ® Chino 13770 Ramona A v enue • Chino , California 91710 (909) 628-8942 F AX (909) 590-4910 (800) 395-9229 K eep this booklet with the case at all times f or futur e r eference. THIS BOOKLET CONT AINS INFORMA TION ON: RED A narro w depth multi dec k air cur tain case designed to display pre-packag[...]

  • Page 3

    Rev.0 309 3 Cut & Plan Vie ws 23 1 / 8 " 12" 14" 18" 22 1 / 2 " 6 1 / 2 " 58 1 / 2 " 40 1 / 8 " 14 1 / 4 " RED Refrigerated Self Sevice End Display Scale = 1/2" 33 1 / 2 " 39" Elec. Ref. Drain 1" 33 1 / 2 " 72" ( Va r i able ) RED Plan View Scale = 1/4" 1" 39&q[...]

  • Page 4

    IGUP-RED-0309 4 LOCA TION The refrigerated mer chandisers hav e been designed f or use only in air conditioned stor es where temperatur e and humidity ar e maintained at or below 75°F and 55% rela- tive humidity . DO NO T allow air conditioning, electric fans, ov ens, open doors or windows (etc .) to cr eate air cur - r ents ar ound the merchandis[...]

  • Page 5

    Rev.0 309 5 Plumbing WASTE OUTLET AND P-TRAP The waste outlet is located in the center , 8" fr om the front of the case. A 7/8" P-trap and thr eaded adapter ar e supplied with each fixture. The P-trap must be installed to pr ev ent air leakage and insect entrance into the fixtur e . NOTE: PVC-DWV solvent cement is recommended. Follow Huss[...]

  • Page 6

    IGUP-RED-0309 6 Refrigeration REFRIGERANT TYPE The standard r efrigerant will be R-22 unless otherwise specified on the customer order . Check the serial plate on the case for information. PIPING The r efrigerant line outlets are located under the fixtur e at the left hand end when view ed from the back. Insulate the suction lines to pr ev ent cond[...]

  • Page 7

    Rev.0 309 7 Electrical WIRING COLOR CODE GREEN GROUND PURPLE ANTI-SWEA T ORANGE LIGHTS YELLO W RECEPT ACLE RED / BLACK T -ST A T /SOLENOID 230V BLACK / WHITE T - S TAT / S O L E N O I D 115V BRO WN F AN MOT ORS CASE MUST BE GROUNDED NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” box[...]

  • Page 8

    IGUP-RED-0309 8 Case Specifications Model Refrigeration A verage Disch. Air T~Stat Coil Fan Blade Qty . Defrosts Elec. Load (Amps) @ ~1 15 V AC & Btu / Hr . T emperatures (°F) Speed Settings T ype Size (in) & Evap. per day Fans Fans Case Shelf Length (Ft.) (T otal) Evap. Prod. Disch. (CFM) (°F) Pitch ( ° ) Fans Min. Qty . Eng. Eff. Std. [...]

  • Page 9

    Rev.0 309 9 Electrical Schematic DATE: PROJEC T TITLE: DRAWING #: DRAWN BY: PRODUC TION ORDER #: DRAWING TITLE: DATE: Hussmann Corporation, Int'l. 13770 Ramona Avenue Chino, CA. 91710 (909)-590-4910 Lic.#: 644406 REVISIONS: #: DESCR IPTION: CHECKED BY: BY: FILE LOCATION : D.QUAN --- PAGE OF  11 06/08/01 H:WIRESCHEMATICSNE WW IRE RED CASES[...]

  • Page 10

    IGUP-RED-0309 10 User Information STOCKING Improper temperatur e and lighting will cause serious prod- uct loss. Discoloration, dehydration and spoilage can be controlled with pr oper use of the equipment and handling of pr oduct. Product temperatur e should alwa ys be main- tained at a constant and pr oper temperature. This means that fr om the ti[...]

  • Page 11

    Rev.0 309 11 PLEXIGLASS & ACRYLIC CARE CLEANING Clean with plenty of nonabrasiv e soap (or detergent) and luk e warm water , using the bare hand to feel and dislodge any cak ed-on dir t. A soft, grit-free cloth, sponge or cham- ois ma y be used, but only as a means of carrying the water to the plastic. Dr y with a clean damp chamois or clean so[...]

  • Page 12

    IGUP-RED-0309 12 APPENDIX A. – Temperature Guidlines The refrigerators should be operated according to Hussmann’s published engineering specifications for entering air temperatures for specific equipment applications. Table 1 shows the typical temperature of the air entering the food zone one hour before the start of defrost and one hour after [...]

  • Page 13

    Rev.0 309 13 1°C (1.8°F). Temperature measuring devices that are scaled only in Fahrenheit shall be accurate to 2°F. The thermometer should be checked for proper calibration. (It should read 32°F when the stem is immersed in an ice water bath). b) LOCATION – The probe or sensing element of the thermometer should be located in the airstream wh[...]

  • Page 14

    IGUP-RED-0309 14[...]

  • Page 15

    Rev.0 309 15 LIMITED WARRANTY This warranty is made to the original user at the original installation site and is not transferable. Hussmann merchandisers ar e war ranted to be fr ee fr om def ect in material and w orkmanship under normal use and ser vice for a period of one (1) year fr om the date of original installation (not to exceed fifteen (1[...]

  • Page 16

    IGUP-RED-0309 16 The MODEL NAME and SERIAL NUMBER is required in or der to pr ovide you with the correct parts and information for y our particular unit. They can be found on a small metal plate on the unit. Please note them below for futur e refer ence. MODEL: SERIAL NUMBER: /Chino Additional copies of this publication may be obtained b y contacti[...]