Go to page of
Similar user manuals
-
Kitchen Utensil
hussman P/N IGUP-AB-0904
27 pages 0.74 mb -
Refrigerator
hussman FMSS-L
25 pages 2.68 mb -
Refrigerator
hussman P/N 0425683F
27 pages 1.18 mb -
Saw
hussman VGM
24 pages 0.54 mb -
Carrying Case
hussman HUSSMANN Dipping and Display Case
18 pages 0.27 mb -
Cookware
hussman SCSS-SL
24 pages 0.79 mb -
Network Router
hussman P/N 374511B
34 pages 0.24 mb -
Carrying Case
hussman DCSG
18 pages 0.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of hussman SCSS-SL, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of hussman SCSS-SL one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of hussman SCSS-SL. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of hussman SCSS-SL should contain:
- informations concerning technical data of hussman SCSS-SL
- name of the manufacturer and a year of construction of the hussman SCSS-SL item
- rules of operation, control and maintenance of the hussman SCSS-SL item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of hussman SCSS-SL alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of hussman SCSS-SL, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the hussman service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of hussman SCSS-SL.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the hussman SCSS-SL item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
/Chino SCSS / SCSS-SL SER VICE BAKER Y REV . 0108 Installation & Operation Manual SCSS / SCSS-SL SER VICE BAKER Y P/N IGSSB-SCSS / SCSS-SL-0108 INST ALLA TION & OPERA TION GUIDE[...]
-
Page 2
IGSSB-SCSS / SCSS-SL-0108 2 /Chino A publication of Hussmann ® Chino 13770 Ramona A v enue • Chino , California 91710 (909) 628-8942 F AX (909) 590-4910 (800) 395-9229 K eep this booklet with the case at all times for future r eference. THIS BOOKLET CONT AINS INFORMA TION ON: MODEL DESCRIPTIONS All models are a vailable in either 48”, 60” le[...]
-
Page 3
Rev. 0108 3 report and r equir ed claim forms. SHOR T AGES Check y our shipment for an y possible shortages of mate- rial. If a shor tage should exist and is f ound to be the re- sponsibility of Hussmann Chino , notify Hussmann Chino . I f such a shortage involv es the car rier , notify the carr ier imme- diately , and r equest an inspection. Hussm[...]
-
Page 4
IGSSB-SCSS / SCSS-SL-0108 4 Cut & Plan Views 40 3 / 4 " (S/C Height) SCSS Summit Cake Service Bakery Case (Remote & Self Contained) Scale = 1/2" 12 " 9 3 / 4 " 25 1 / 2 " 11 3 / 4 " 15 1 / 4 " 7 3 / 4 " 14 3 / 4 " (Low T emp Ht) 21 1 / 4 " (S/C Height) 15 3 / 4 " (Remote Height) 35 1 / [...]
-
Page 5
Rev. 0108 5 LOCA TION The refrigerated mer chandisers hav e been designed f or use only in air conditioned stor es wher e temperatur e and humidity are maintained at or belo w 75 ° F and 55% r ela- tive humidity . DO NO T allow air conditioning, electric fans, ov ens, open doors or windows (etc.) to create air cur - rents ar ound the merchandiser [...]
-
Page 6
IGSSB-SCSS / SCSS-SL-0108 6 Plumbing WASTE OUTLET AND P-TRAP The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture. A 3/4" P-trap and thr eaded adapter ar e supplied with each fixture. The P-trap must be installed to pr e vent air leakage and insect entrance into the fixt[...]
-
Page 7
Rev. 0108 7 Refrigeration REFRIGERANT TYPE The standard r efrigerant will be R-22 unless otherwise specified on the customer order . Check the serial plate on the case for information. REFRIGERA TION LINES LIQUID SUCTION 3/8" O.D. 5/8" O.D. NOTE: The standard coil is piped at 5/8" (suction); however, the store tie-in may vary dependi[...]
-
Page 8
IGSSB-SCSS / SCSS-SL-0108 8 T-STAT LOCATION T -Stats are located within the electrical race wa y . Condensing Unit Installation Requirements For pr oper operation of the Condensing Unit pr ovide an opening with adequate exhause and intak e as follo ws: Up to 1 1/2 hp: minimum of 2 v ents totalling 150 sq. in. Over 1/2 hp: minimum of 2 vents totalli[...]
-
Page 9
Rev. 0108 9 Electrical WIRING COLOR CODE GREEN GROUND PURPLE ANTI-SWEA T ORANGE LIGHTS YELLOW RECEPT ACLE RED / BLACK T -STA T /SOLENOID 230V BLACK / WHITE T -S TAT / SOLENOID 115V B RO W N FAN MO TORS CASE MUST BE GROUNDED NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes. ELECT[...]
-
Page 10
IGSSB-SCSS / SCSS-SL-0108 10 EKC 201 CONTROLLERS EKC 201 Fig. 1 t room = 0 → +55 ° C t system = – 60 → +50 ° C 12 V a.c./230 V a.c. 2.5 V A IP 54 Identification (See figs 1 and 2). 1. Light emitting diode = refrigeration = defrost = fan running 2. Minus sign 3. Display (Flashes when setting value for room temp. is displayed). 4. Keys for pr[...]
-
Page 11
Rev. 0108 11 Controller application setting parameters P ara- Controller Min. Max. F actory Actual Setting and read-off parameters meter application no. value value setting setting codes 12 34 1 ) The compressor relay closes when the room temperature exceeds the setting value and diff erential. 2 ) Alar m is released and sensor failure is indicated[...]
-
Page 12
IGSSB-SCSS / SCSS-SL-0108 12 User Information STOCKING In order to maximize pr oduct life , maintain a constant and pr oper pr oduct temperature fr om the time the product is receiv ed thr ough storage, preparation and displa y . Products should not be placed in mer chandisers until all refrigeration contr ols hav e been adjusted and mer chandisers[...]
-
Page 13
Rev. 0108 13 2. Scrub thor oughly , cleaning all surfaces, with soap and hot water . 3. Rinse with hot water , but do not flood. 4. Apply the sanitizing solution according to Hussmann’ s directions. 5. Rinse thoroughl y . 6. Dr y completely bef or e resuming operation. CLEANING PRECAUTIONS WHEN CLEANING : • DO NOT WATER OVER 140 ° F • DO NOT[...]
-
Page 14
IGSSB-SCSS / SCSS-SL-0108 14 Maintenance ELECTRICAL PRECAUTIONS BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component This includes (but not limited to) Fans, Heaters, Thermostats, and Lights. REPLACING FLUORESCENT LAMPS Fluorescent lamps ar e furnished with a shatterproo[...]
-
Page 15
Rev. 0108 15 Electrical Schematics Date: Project Title: Drawing N o.: Drawn By : Assembly: Drawin g Title: Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue Chino , CA. 91710 (909)- 590-491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Boris Kasr el BJK Sheet of W 8000001mnl H:Wir ingSc hematicsNewWi ri[...]
-
Page 16
IGSSB-SCSS / SCSS-SL-0108 16 Date: Project Title: Drawing N o.: Drawn By : Ass embly : Dra wing Title : Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue Chino , CA. 91710 (909)- 590-491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Boris Kasr el BJK Sheet of H:Wir ingSc hematicsIn-Wor k... 495-01-... [...]
-
Page 17
Rev. 0108 17 Date: Project Title: Drawing N o.: Drawn By : Ass embly : Dra wing Title : Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue Chino , CA. 91710 (909)- 590-491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Boris Kasr el BJK Sheet of H:Wir ingSc hematicsIn-Wor k... 495-01-... / 880... 03. 28.[...]
-
Page 18
IGSSB-SCSS / SCSS-SL-0108 18 Date: Project Title: Drawing N o.: Drawn By : Ass embly : Dra wing Title : Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue Chino , CA. 91710 (909)- 590-491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Boris Kasr el BJK Sheet of H:Wir ingSc hematicsIn-Wor k... 495-01-... [...]
-
Page 19
Rev. 0108 19 APPENDIX A. – TEMPERATURE GUIDELINES REFRIGERATED The refrigerators should be operated according to Hussmann ’ s published engineering specifications for en- tering air temperatures for specific equipment applica- tions. Table 1 shows the typical temperature of the air entering the food zone one hour before the start of defrost and[...]
-
Page 20
IGSSB-SCSS / SCSS-SL-0108 20 this evaluation, product temperature above the FDA Food Code 1993 temperature for potentially hazardous food will be the first indication that an evaluation should be performed. It is expected that all refrigerators will keep food at the FDA Food Code 1993 temperature for potentially hazardous food. 1.1 The following re[...]
-
Page 21
Rev. 0108 21 ments with detergent and water will keep the equip- ment presentable and prevent grime buildup. 1.2 Load levels as defined by Hussmann must be ob- served. 1.3 The best preservation is achieved by following these rules: a) Buy quality products. b) Receive perishables from transit equipment at the ideal temperature for the particular pro[...]
-
Page 22
IGSSB-SCSS / SCSS-SL-0108 22[...]
-
Page 23
Rev. 0108 23 Limited W arranty This warranty is made to the original user at the original installation site and is not transf erable . Hussmann mer chandisers are war ranted to be fr ee fr om defect in material and w orkmanship under normal use and ser vice for a period of one (1) y ear from the date of original installation (not to exceed fifteen [...]
-
Page 24
IGSSB-SCSS / SCSS-SL-0108 24 The MODEL NAME and SERIAL NUMBER is required in or der to pr ovide y ou with the corr ect parts and information for your particular unit. They can be f ound on a small metal plate on the unit. Please note them below for futur e r eference. MODEL: SERIAL NUMBER: /Chino Additional copies of this publication ma y be obtain[...]