Ingersoll-Rand PH30F-XXX-XXX-C manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PH30F-XXX-XXX-C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PH30F-XXX-XXX-C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PH30F-XXX-XXX-C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ingersoll-Rand PH30F-XXX-XXX-C should contain:
- informations concerning technical data of Ingersoll-Rand PH30F-XXX-XXX-C
- name of the manufacturer and a year of construction of the Ingersoll-Rand PH30F-XXX-XXX-C item
- rules of operation, control and maintenance of the Ingersoll-Rand PH30F-XXX-XXX-C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PH30F-XXX-XXX-C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PH30F-XXX-XXX-C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PH30F-XXX-XXX-C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PH30F-XXX-XXX-C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET – BRY AN, OHIO 43506  (800) 276-4658 y F AX (800) 266-7016 © 2010 CCN 15307648 www.ingersollrandproducts.com OPERA T OR’S MANU AL PH30F-X XX - XX X -C INCL UDING: OPERA TION, INST ALLA TION & MAINTENANCE RELEASED: 5-28-08 REVISED: 11 -1 3 -10 (REV . 0 4 ) 3" DIAPHRA GM PUMP 2:1 RA [...]

  • Page 2

    Page 2 of 8 PH30F-XX X-X XX-C (en) W ARNING EX CESSIVE AIR PRESSURE. Can cause per- sonal injury , pump damage or property damage. Do not ex ceed the maximum inlet air pressure as stated on the pump model plate . Be sure material hoses and other componen ts are able to withstand fluid pressures dev eloped by this pump . Check all hoses for damage o[...]

  • Page 3

    PH30F-XX X-X XX-C (en) Page 3 of 8 y Hytrel® and V iton® are register ed trademarks of the DuPont Company y L octite® and 242® are registered trademarks of Henkel L octite Corporation y y Santoprene® is a regist ered trademark of Monsanto Company , licensed to Advanced Elastomer Sy stems, L.P . y ARO® is a registered trademark of Ingersoll-Ra[...]

  • Page 4

    Page 4 of 8 PH30F-XX X-X XX-C (en) P ARTS LIST / PH30F- XXX -X XX -C FLUID SECTION c 637441-X X Fluid Section S ervice Kits include: Balls (see Ball Option, refer to - XXX in chart below), Diaphragms (see Diaphragm Op- tion, refer to - XXX in chart below), and items 3, 19, 70, 144, 175 and 196 (listed below) plus items 174 and 94276 Lubripla te F M[...]

  • Page 5

    PH30F-XX X-X XX-C (en) Page 5 of 8 ) ASSEMBL Y T ORQUE REQUIREMENTS ( NO TE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. (14) Cap screw , 65 - 70 ft lbs (88.1 - 94.9 Nm). (26) Manifold screw , 60 - 70 ft lbs (81.4 - 94.9 Nm). (27) Fluid cap screw , 60 - 70 ft lbs (81.4 - 94.9 Nm). (131) Screw , 35 - 40 ft lbs (47.5 - 54.2 Nm). L UBRIC[...]

  • Page 6

    Page 6 of 8 PH30F-XX X-X XX-C (en) P ARTS LIST / PH30F- XXX -X XX -C AIR SEC TION d Indicates parts included in 637369 air sec tion service kit shown below and items 70, 144, 175 and 180 shown on page 4. MA TERIAL CODE [B] = Nitrile [I] = Iron [Br] = Brass [P] = Polypropylene [C] = Carbon Steel [Sp] = Santoprene [Ck] = Ceramic [SS] = Stainless Stee[...]

  • Page 7

    PH30F-XX X-X XX-C (en) Page 7 of 8 P ARTS LIST / PH30F- XXX -X XX -C AIR SEC TION ) ASSEMBL Y T ORQUE REQUIREMENTS ( NO TE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. (105) Screw , 15 - 20 in. lbs (1.7 - 2.3 Nm). (134) Screw , 40 - 50 in. lbs (4.5 - 5.6 Nm). L UBRICA TION / SEALANTS f Apply Lubriplate FML -2 grease to all “ O” ri[...]

  • Page 8

    Page 8 of 8 PH30F-XX X-X XX-C (en) PN 97999-1381 TROUBLE SHOO TING Product discharged from e xhaust outlet. Check for diaphragm ruptur e. Check tightness of (14) cap screw . Air bubbles in product discharge. Check connections of suction plumbing. Check “O” rings between intake manifold and  uid caps. Check tightness of (14) cap screw . Motor[...]