Go to page of
Similar user manuals
-
Water Pump
Ingersoll-Rand 613123-XXX-C
2 pages 0.18 mb -
Water Pump
Ingersoll-Rand 650736-15X
1 pages 0.07 mb -
Water Pump
Ingersoll-Rand 66615X-X-C
8 pages 0.6 mb -
Water Pump
Ingersoll-Rand PD10X-X-X
8 pages 0.97 mb -
Water Pump
Ingersoll-Rand TWO BALL PUMP SERIES 650409-X
2 pages 0.12 mb -
Water Pump
Ingersoll-Rand 613100-1
6 pages 0.33 mb -
Water Pump
Ingersoll-Rand 650311-X & 650312-X
2 pages 0.26 mb -
Water Pump
Ingersoll-Rand NM2328A-X
2 pages 0.1 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PW10A-X-X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PW10A-X-X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PW10A-X-X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Ingersoll-Rand PW10A-X-X should contain:
- informations concerning technical data of Ingersoll-Rand PW10A-X-X
- name of the manufacturer and a year of construction of the Ingersoll-Rand PW10A-X-X item
- rules of operation, control and maintenance of the Ingersoll-Rand PW10A-X-X item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PW10A-X-X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PW10A-X-X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PW10A-X-X.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PW10A-X-X item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
E 2010 CCN 15207962 (800) 276-4658 D F AX (800) 266-7016 INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET BR Y AN, OHIO 43506 1” DIAPHRAGM PUMP OPERA T OR’S MANUAL P W 1 0 A -X -X RELEASED: 3-1 1-04 REVISED: 5-19-10 (REV . 05) INCLUDING: OPERA TION, INST ALLA TION & M AINTENANCE 1:1 RA TIO (MET ALLIC) READ THIS MANUAL CAREFULL Y BEFOR[...]
-
Page 2
PW 10 A -X -X Page 2 of 8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND, AND FOLLOW THIS INFORMA TION TO A VOID INJUR Y AND PROPERTY DAMAGE. EXCESSIVE AIR PRESSURE ST A TIC SP ARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EXCESSIVE AIR PRESSURE. Can cause person - al injury , pump damage or property damage. S Do not exceed the maximum [...]
-
Page 3
Page 3 of 8 PW 10 A -X -X GENERAL DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / fluid sections. Air operated double diaphragm pumps utilize a pres[...]
-
Page 4
MA TERIAL CODE [A] = Aluminum [B] = Nitrile [C] = Carbon Steel [Co] = Copper [E] = E.P .R. [H] = Hytrel [SP] = Santoprene [SS] = Stainless Steel [T] = PTFE [V] = Viton PW 10 A -X -X Page 4 of 8 P ARTS LIST / PW10A -X-X FLUID SECTION L 637401-XX FLUID SECTION SERVICE KITS INCLUDE: BALLS (see Ball Option, refer to -X X in Service Kit chart below), DI[...]
-
Page 5
Page 5 of 8 PW 10 A -X -X P ARTS LIST / PW10A -X-X FLUID SECTION COLOR CODE 15 FOR THE AIR MOTOR SECTION SEE P AGES 6 & 7 Santoprene 8 PTFE 7 131 , x 175 k Figure 2 View of two piece PTFE diaphragm 29 , 144 k 70 k . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. (14) screw , tighten to 25 - 30 f t lbs (33.[...]
-
Page 6
PW 10 A -X -X Page 6 of 8 P ARTS LIST / PW10A -X-X AIR SECTION n Indicates parts included in 637397 Air Section Service Kit shown below and items (70), (144), (175) and (180) shown on page 4. AIR MOTOR P ARTS Item Description (size) Qt y Part No. [Mtl] Item Description (size) Qty Part No. [Mtl] 101 Center Body (1) 95888 [A] 103 Bushing (1) 96000 [D[...]
-
Page 7
Page 7 of 8 PW 10 A -X -X P ARTS LIST / PW10A -X-X AIR SECTION 168 k . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. T orque (105) screws t o 35 - 40 in. lbs (4.0 - 4. 5 Nm). T orque (134) screws t o 40 - 50 in. lbs (4.5 - 5. 6 Nm). LUBRICA TION / SEALANTS k Apply Lubriplate FML- 2 grease to “O” rings, ?[...]
-
Page 8
PW 10 A -X -X Page 8 of 8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of (14) diaphragm screw . Air bubbles in product discharge. S Check connections of suction plumbing. S Check “O” rings between intake manifold and inlet side fluid caps. S Check tightness of (14) diaphragm screw . [...]