Go to page of
Similar user manuals
-
Oxygen Equipment
Invacare XPO100B
48 pages 2.39 mb -
Oxygen Equipment
Invacare 10
68 pages 1.43 mb -
Oxygen Equipment
Invacare IRC10LXO2
32 pages 0.93 mb -
Oxygen Equipment
Invacare HF2E540M9
24 pages 1.3 mb -
Oxygen Equipment
Invacare IRC5LX
32 pages 0.93 mb -
Oxygen Equipment
Invacare XPO100
48 pages 2.39 mb -
Oxygen Equipment
Invacare HF2POST6
24 pages 0.63 mb -
Oxygen Equipment
Invacare XL
68 pages 1.43 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Invacare HF2E540M9, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Invacare HF2E540M9 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Invacare HF2E540M9. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Invacare HF2E540M9 should contain:
- informations concerning technical data of Invacare HF2E540M9
- name of the manufacturer and a year of construction of the Invacare HF2E540M9 item
- rules of operation, control and maintenance of the Invacare HF2E540M9 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Invacare HF2E540M9 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Invacare HF2E540M9, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Invacare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Invacare HF2E540M9.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Invacare HF2E540M9 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Dealer: This manual MUST be given to the end user. User: Before using this cylinder, read this manual and save for future reference. For more information regarding Invacare products, parts, and services, please visit www.invacare.com Operator’s Manual HomeFill ® Cylinder Oxygen 540 Valve HF2E540M9 “Caution: Federal law restricts ?[...]
-
Page 2
HomeFill ® Cylinder 2 Part No 116315 6 WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UN DERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE[...]
-
Page 3
TABLE OF CONTENTS Part No 1163156 3 HomeFill ® Cylinder TABLE OF CONTENTS SPECIAL NOTES ............................................... 4 RECEIVING INSPECTION .................................. 4 INTENDED USE ................................................ 4 SECTION 1—GENERAL GUIDELINES .................. 5 SECTION 2—FEATURES ................[...]
-
Page 4
SPECIAL NOTES HomeFill ® Cylinder 4 Part No 116315 6 SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for ?[...]
-
Page 5
SECTION 1—GENERAL GUIDELINES Part No 1163156 5 HomeFill ® Cylinder SECTION 1—GENERAL GUIDELINES WARNING SECTION 1 - GENERAL GU IDELINES contains important information for the safe operation and use of this product. DANGER This product is not intended as a life-sustaining or life-supporting device. WARNING Only personnel ins[...]
-
Page 6
SECTION 1—GENERAL GUIDELINES HomeFill ® Cylinder 6 Part No 116315 6 WARNING DO NOT attempt to repair product. DO NOT immerse product in any kind of liquid. Store product in a clean area when not in use. Only use an Invacare Cor[...]
-
Page 7
SECTION 1—GENERAL GUIDELINES Part No 1163156 7 HomeFill ® Cylinder WARNING NEVER oil or lubricate the cylinder fittings. NEVER use any penetrating oil or lubricant such as WD ‐ 40 or 3 in One. If connection difficulty is experienced ve r[...]
-
Page 8
SECTION 2—FEATURES HomeFill ® Cylinder 8 Part No 116315 6 SECTION 2—FEATURES FIGURE 2.1 Product Diagram Cylinder Fill Port Cylinder Valve 540 Connection Port (with Protective Cap)[...]
-
Page 9
SECTION 3—TYPICAL PRODUCT PARAMETERS Part No 1163156 9 HomeFill ® Cylinder SECTION 3—TYPICAL PRODUCT PARAMETERS DIMENSIONS : Weight 5.1 lbs (2.31 kg ) Overall Length 13.25 in (33.6 cm) Diameter 4.4 in (11.1 cm) STORAGE CONDITIONS TEMPERATURE: -40°F (-40°C) to 140°F (60°C) MAXIMUM HUMIDIT Y: 95%[...]
-
Page 10
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 10 Part No 1163156 SECTION 4—INSPECTION AND COMPRESSOR INTERFACE NOTE: Refer to the HomeFill ® Compr essor Owner’s Manual for compressor operating instructions. Cylinder Prefill Inspection WARNING All cylinders MUST be inspe[...]
-
Page 11
SECTION 4—INSPECTION AN D COMPRESSOR INTERFACE Part No 1163156 11 HomeFil l ® Cylinder External Examination 1. Examine the outside of the cylinder for the following conditions and replace the cylinder if they exist: •D e n t s or dings •A r c burns •O i l or ?[...]
-
Page 12
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 12 Part No 1163156 Checking Cylinder Pressure WARNING NEVER use tools of any kind to conn ect/disconnect the cylinder and the compressor. Otherwise, severe injury and/or damage may occur. DO NOT drop oxygen cylind ers. Use two hands when handling/transporting oxygen cylinders.[...]
-
Page 13
SECTION 4—INSPECTION AN D COMPRESSOR INTERFACE Part No 1163156 13 HomeFil l ® Cylinder Filling the Cylinder NOTE: For this procedure, ref e r to FIGURE 4.1 thru FIGURE 4.6. 1. Check the cylinder pressure before attempting to fill cylinder . Refer to Checking [...]
-
Page 14
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 14 Part No 1163156 FIGURE 4.2 Fillport Covers 5. On the compressor unit, momentarily push DOWN on the outer ring (sleev e) of the connector fillport to reset the connector (FIGURE 4.3). Connector F[...]
-
Page 15
SECTION 4—INSPECTION AN D COMPRESSOR INTERFACE Part No 1163156 15 HomeFil l ® Cylinder NOTE: If the outer ring (sleeve) is in the UP position (GREEN dots not visible), the connector fillport will not be able to accept the cylinder fillport. ?[...]
-
Page 16
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 16 Part No 1163156 NOTE: Refer to Cylinder Fill Ti m e s on page 20 for the length of time it will take to fill the cylinder . FIGURE 4.4 Connecting the Cylinde r to the Compressor Cylinder Compressor Crad[...]
-
Page 17
SECTION 4—INSPECTION AN D COMPRESSOR INTERFACE Part No 1163156 17 HomeFil l ® Cylinder 11. After the cylinder is full, press the compressor pow er switch to the Off (O) position (FIGURE 4.5). 12. Grasp the cylinder assembly (FIGURE 4.5). 13. W ith the oth[...]
-
Page 18
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 18 Part No 1163156 WARNING The fillport cover on the co nnector fillport and the post valve fillport MUST be replaced after filling and whenever not in use. If either of th e fillport covers are missing contact your healthcare provider before using. 17. Place the fillp[...]
-
Page 19
SECTION 5—MAINTENANCE Part No 1163156 19 HomeFil l ® Cylinder SECTION 5—MAINTENANCE 1. After each use, cl ean exterior of the product with a dry , lint free cloth only . 2. Store product in a clean area free from grease, oil, and other sourc[...]
-
Page 20
SECTION 6—CYLINDER FILL TIMES HomeFill ® Cylinder 20 Part No 1163156 SECTION 6—CYLINDER FILL TIMES NOTE: All filling times are appr oximate and may vary on environmental conditions. * Troubleshooting If post va l ve cylind er fails to function, try the following ?[...]
-
Page 21
NOTES Part No 1163156 21 HomeFil l ® Cylinder NOTES[...]
-
Page 22
LIMITED WARRANTY HomeFill ® Cylinder 22 Part No 1163156 LIMITED WARRANTY PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the origina l purchaser/user of our products. This warranty gives you specific legal rights and you may al so [...]
-
Page 23
LIMITED WARRANTY Part No 1163156 23 HomeFil l ® Cylinder LIMITATIONS AND EXCLUSIONS : THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BE EN REMOVED OR DEFACED; PRODUC TS SUBJECTED TO NEGL IGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENA NCE, OR STORAGE; PRODUCTS MODIFIED WITHOUT INVACARE’S EXPRESS WRITTE[...]
-
Page 24
Invacare Corporation www.invacare.co m USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 Technical Services 800-832-4707 All rights reserved . Trademarks are identified by the symbols ™ and ®. All trademarks are owned by or licensed to Invacare Corporati on or its subsidiaries unless otherwise noted. © 2009 Invacare Corporation Part[...]