Go to page of
Similar user manuals
-
Oxygen Equipment
Invacare Perfecto2
86 pages 3.95 mb -
Oxygen Equipment
Invacare HF2POST9
24 pages 0.63 mb -
Oxygen Equipment
Invacare IRC5LXAW
36 pages 0.92 mb -
Oxygen Equipment
Invacare IRC10LX
32 pages 0.93 mb -
Oxygen Equipment
Invacare CE0123
96 pages 0.65 mb -
Oxygen Equipment
Invacare HF2E540M9
24 pages 1.3 mb -
Oxygen Equipment
Invacare XL
68 pages 1.43 mb -
Oxygen Equipment
Invacare IRC10LXO2
32 pages 0.93 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Invacare IRC10LXO2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Invacare IRC10LXO2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Invacare IRC10LXO2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Invacare IRC10LXO2 should contain:
- informations concerning technical data of Invacare IRC10LXO2
- name of the manufacturer and a year of construction of the Invacare IRC10LXO2 item
- rules of operation, control and maintenance of the Invacare IRC10LXO2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Invacare IRC10LXO2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Invacare IRC10LXO2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Invacare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Invacare IRC10LXO2.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Invacare IRC10LXO2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Dealer: This manual MUST be given to the end user. User: Before using this prod uct, read this manual and save for futu re reference. Operator’s Manual For more information regarding Invacare products, parts, and services, please visit www.invacare.com Platinum ™ Series XL, 5, 10 Oxygen Concentrators Standard, with SensO 2 ® and HomeFill ® In[...]
-
Page 2
WARNING Platinum ™ Series 2 P art No 1118353 WARNING DO NOT use this product or any av ailable optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner ’ [...]
-
Page 3
Part No 1118353 3 Platinum ™ Series TABLE OF CONTENTS TABLE OF CONTENTS ACCESSORIES .................................................. 2 REGISTER YOUR PRODUCT .............................. 4 SPECIAL NOTES ............................................... 5 LABEL LOCATION ............................................ 7 SECTION 1—GENERAL GUIDELINES[...]
-
Page 4
TABLE OF CONTENTS Platinum ™ Series 4 Part No 1118353 TABLE OF CONTENTS SECTION 6—MAINTENANCE .......................... 23 Routine Maintenanc e ....................... ................................................. 23 Cleaning the Cabinet Filter ..................... ....................... ............. 23 Cleaning the Cabinet ............[...]
-
Page 5
SPECIAL NOTES Part No 1118353 5 Platinum ™ Series SPECIAL NOTES Signal w ords are used in this man ual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for ?[...]
-
Page 6
SPECIAL NOTES Platinum ™ Series 6 Part No 1118353 CAUTION “Caution: Federal law restricts this device to sale or rental by or on order of a physician, or any other practitioner licensed by the law of the State in which he/she [...]
-
Page 7
LABEL LOCATION Part No 1118353 7 Platinum ™ Series LABEL LOCATION HomeFill II Compatib le I/O Operating Instructions (See Operator's Manual) Alarms (See Operator's Manual) W ARNING - RISK OF FIRE NO SMOKING - Keep ALL sources of ignition out of the room in which this product is located and awa y from areas where oxygen is being delivere[...]
-
Page 8
SECTION 1—GENERAL GUIDELINES Platinum ™ Series 8 Part No 1118353 SECTION 1—GENERAL GUIDELINES In order to ensure the safe installation, assembly and operation of the Platinum concentrator these instructions MUST be followed. WARNING This section contains i[...]
-
Page 9
SECTION 1—GENERAL GUIDELINES Part No 1118353 9 Platinum ™ Series Operating Information For optimum performance, Inv acare recommends that each concentrator be on and running for a minimum of 30 minutes at a time. Shorter periods of operation may [...]
-
Page 10
SECTION 1—GENERAL GUIDELINES Platinum ™ Series 10 Part No 1118353 Other devices may experience interference from ev en the low levels of electromagnetic emissions permitted by the above standards. To determine if the emissions from the Platinum ?[...]
-
Page 11
SECTION 2—FEATURES Part No 1118353 11 Platinum ™ Series SECTION 2—FEATURES Oxygen Outlet Flowmeter Oxygen Purity Indicator Lights (SensO 2 model only )/ Fault and Power Indicator Lights (LX model only) Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter (one of two shown) REAR VIEW ACCESSORIES (NOT SHOWN): Remote Humidifier/Flo wme[...]
-
Page 12
SECTION 3—HANDLING Platinum ™ Series 12 Part No 1118353 SECTION 3—HANDLING The concentrator should AL W A YS be kept in the upright position to prevent cabinet damage while being transported. If the concentrator is to be reshipped by common car[...]
-
Page 13
SECTION 4—TYPICAL PRODUCT PARAMETERS Part No 1118353 13 Platinum ™ Series SECTION 4—TYPICAL PRODUCT PARAMETERS *NOTE: Stated concentrati on levels achieved after initial warm ‐ up period (appr oximately 30 minutes). Electrical Requirements: 120 VAC ± 10% (132 VAC/10 8 VAC), 60 Hz Rated Current In[...]
-
Page 14
SECTION 4—TYPICAL PRODUCT PARAMETERS Platinum ™ Series 14 Part No 1118353 Flow Range: Platinum 5 and XL - 0.5 to 5 L/min For flowrates less than 1 L/min, we recommend the use of the Invacare Pediatric Flowmeter IRCPF16 Accessory. Platinum 10 - 2 L/min to 10 L/min Low Flow Alarm: Platinum 5 - 0 L/min to 0.5 L/min, Platinum 10 - 0 L/min to 1 L/m [...]
-
Page 15
SECTION 4—TYPICAL PRODUCT PARAMETERS Part No 1118353 15 Platinum ™ Series Operating Ambient Temperature: 50°F - 95°F (10°C - 35°C) at 20-60% relative humidity Exhaust: Platinum 5 and XL: Less than Ambient + 35°F (+19°C). Platinum 10: Less than Ambient + 45°F (+25°C) Oxygen Output Temperature: Platinum 5 and XL: Less than Ambient + 4°F [...]
-
Page 16
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 16 Part No 1118353 SECTION 5— OPERATING INSTRUCTIONS Introduction Yo u r oxygen concentrator is intended for individual use indoors. It is an electronically operated device that separates oxygen from room air . ?[...]
-
Page 17
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 17 Platinum ™ Series Set-Up Plug in Power Cord Plug in pow er cord to an electrical outlet. POLARIZED PLUG WARNING As a safety feature, this appliance may hav e a polarized plug (one blade is wider than ?[...]
-
Page 18
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 18 Part No 1118353 FIGURE 5.2 Humidifier Compartmen t 3. Remove the filter access door located on the side of the concentrator . Insert a flathead screwdriv er in the plate groove on the top edge of [...]
-
Page 19
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 19 Platinum ™ Series 7. Attach oxygen tubing from the humidifier bottle to oxygen outlet connector on the oxygen concentrator (FIGURE 5.4). 8. Attach the cannula/patient supply tubing to the humidifier [...]
-
Page 20
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 20 Part No 1118353 Flowrate NOTE: For this procedure, refe r to FIGURE 5.6 on page 20. 1. T urn the flowrate knob to the setting prescribed by yo ur physician or therapist. CAUTION Never se t the flo[...]
-
Page 21
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 21 Platinum ™ Series Front Panel Indicators - Units with SensO 2 NOTE: For this procedure, refe r to FIGURE 5.7. The SensO 2 feature monitors the purity of oxygen generated by the oxygen concentrator . If purity ?[...]
-
Page 22
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 22 Part No 1118353 Front Panel Indicators - Units without SensO 2 NOTE: For this procedure, refe r to FIGURE 5.8. FIGURE 5.8 Front Panel Indicators - Units without Se nsO2 Initial Startup of the Concentrator NOTE: Concentrator may be used during ?[...]
-
Page 23
SECTION 6—MAINTENANCE Part No 1118353 23 Platinum ™ Series SECTION 6—MAINTENANCE WARNING The Invacare concentrators are specifically designed to minimize routine preventiv e mainte nance. Only qualified personnel should perform preventiv e maintenance on the c[...]
-
Page 24
SECTION 6—MAINTENANCE Platinum ™ Series 24 Part No 1118353 2. Clean the cabinet filters with a vac u um cleaner or wa s h in w arm soapy wa t e r and rinse thoroughly . 3. Dry the filters thoroughly before reinstallation. FIGURE 6.1 Cleaning the Cabinet Filter C[...]
-
Page 25
SECTION 6—MAINTENANCE Part No 1118353 25 Platinum ™ Series FIGURE 6.2 Preventive Maintenance R ecord ON EACH INSPECTION MODEL NO. I R C SERIAL NO. PREVENTIVE MAINTENANCE RECORD INVACARE PLATINUM OXYGEN CONCENTRATOR Record Date of Service Record Elapsed Hours On Hour Meter Clean Cabinet Filter(s) Check Prescribed L/min. Flow Rate EVERY 4,380 HOU[...]
-
Page 26
SECTION 7—TROUBLESHOOTING GUIDE Platinum ™ Series 26 Part No 1118353 SECTION 7—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: SHORT BEEPS, LONG PAUSE Concentrator NOT operating, power switch ON. Beep.... ..Beep... ... Main Power Loss: 1. Power cord NOT plugged in. 1. Insert plug into outlet. 2. No power at outlet. 2. Inspect [...]
-
Page 27
SECTION 7—TROUBLESHOOTING GUIDE Part No 1118353 27 Platinum ™ Series YELLOW or RED LIGHT Illuminated. Alarm: CONTINUOUS On red light only. * Only applies to 5LXO 2 and 10LXO 2 SensO 2 models. 1. Low oxygen purity.* 1. Clean or Replace filters. 2. Kinked or blocked tub- ing, cannula or humidifier.* 2. Inspect for kinks or block- ages. Correct, c[...]
-
Page 28
NOTES Platinum ™ Series 28 Part No 1118353 NOTES[...]
-
Page 29
NOTES Part No 1118353 29 Platinum ™ Series NOTES[...]
-
Page 30
LIMITED WARRANTY Platinum ™ Series 30 Part No 1118353 LIMITED WARRANTY NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURE D AFTER JULY 4, 1975. This warranty is extended only to th e original purchaser who purchases this product when new and unused from Invacare Corporation or a dealer. This wa[...]
-
Page 31
LIMITED WARRANTY Part No 1118353 31 Platinum ™ Series For warranty service, please contact In vacare Corporation's Service Department at the toll free number on the back cover. Upon receiving notice of an alleged de fect in a prod uct, Invacar e Corporatio n will issue a serialized return authorization. It sh all then be the responsibility o[...]
-
Page 32
Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 Technical Services 800-832-4707 Part No 1118353 Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. © 2009 Invacare Corporation Rev J - 4/09 This pr[...]