Invacare MA80 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Invacare MA80, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Invacare MA80 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Invacare MA80. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Invacare MA80 should contain:
- informations concerning technical data of Invacare MA80
- name of the manufacturer and a year of construction of the Invacare MA80 item
- rules of operation, control and maintenance of the Invacare MA80 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Invacare MA80 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Invacare MA80, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Invacare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Invacare MA80.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Invacare MA80 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Owner’s Operator and Maintenance Manual DEALE R: This manual M UST be given to the user of th e product. USER: BEFORE using this product, read this manual an d save for future reference. For mo re inform ation reg arding In va ca re p ro du cts , pa rts, and services, please v isit www.inva care.com MA80 Series MA80 True Low Air Loss System MA85 [...]

  • Page 2

    SPECIAL NOTES MA80 Series 2 Part No 1148138  WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any addition al instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you[...]

  • Page 3

    TABL E OF CON TENT S Part No 1148138 3 MA80 Series TABLE OF CONTENT S SPE CI AL NOT ES ..... ...... ...... ...... ....... ...... ...... ...... ....... ...... ...... ...... ...... . 2 REGISTER YO UR PRODUCT ..... ..... ...... ...... ...... ...... ..... ...... ...... ........ .... 4 TYP ICA L P RO DUC T P ARAM ET ERS ...... ...... ...... ...... .....[...]

  • Page 4

    TABLE OF CONTENTS MA80 Series 4 Part No 1148138 TABLE OF CONTENT S Transferring Patient Fr om/To a Gurney ............ ........................... ........................... ...........................19 Transferring Patient Fr om/To a Wheelchair ....................... ........................... ........................... ......... 19 Preparing[...]

  • Page 5

    TYPICAL PRODUCT PARAMETERS Part No 1148138 5 MA 80 Se rie s TYPICAL PRODUCT PARAMETERS Electric al Paramet ers Performanc e Paramete rs Mechanical P arameters MA80/MA85 INPUT VOLTAGE AC: 90 V INPUT FREQUEN CY: 60 H z CURRENT: 2 A MAXIMU M POWER CONSU MPTION: 150 ± 10 W CIRCUIT PROTECTION: Dual fused, 250 V, 5 A fast blow fuses MODE OF OPERATION: C[...]

  • Page 6

    TYPICAL PRODUCT PARAMETERS MA80 Series 6 Part No 1148138 Environment al Paramet ers MA80/MA85 OPERATING CONDITIONS AMBIENT TEMPERA TURE: RELATIVE HUMIDITY: ATMOSPHERIC PR ESSURE: 50° - 104° F 30% - 75% Non-Condensing 70 - 106 kPa STORAGE AND SHIP PING CONDITIONS AMBIENT TEMPERA TURE: RELATIVE HUMIDITY: ATMOSPHERIC PR ESSURE: -40° - 158° F 10% -[...]

  • Page 7

    LABEL LOCATION Part No 1148138 7 MA 80 Se rie s LABEL LOCAT ION DANGER-EXPLOSION HAZARD: DO NOT us e in the presence of flammable anesthetics. CAUTION: Eq uipment should be connected to a properly grounded receptacle (3-prong). Risk of Electrical shock. DO NOT remove back. Disconnect air hose before administering CPR. NOTE: This label is on the bac[...]

  • Page 8

    SECTION 1—GENERAL GUIDELINES MA80 Series 8 Part No 1148138 SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the s afe operation and use of this product. Contraindications ALW AYS consult the patient’ s physi cian b efore using the MA80 and MA85 systems. Installation The MA80 and MA85 s[...]

  • Page 9

    SECTION 1—GENERAL GUIDELINES Part No 1148138 9 MA 80 Se rie s Fire Hazard  DANGER Smoking DO NOT SMOKE while using this device. This system uses r oom air for circulation through the mattress. A cigarett e can burn a hole i n the bed surface and cause damage to the m attress. Also, p atient cl othing, bed sheets, etc. may be combustible and ca[...]

  • Page 10

    SECTION 2—OPERATION MA80 Series 10 Part No 1148138 SECTION 2—OPERATION CAUTION The control unit and mattress on the MA80 series are designed to be used as a system. DO NOT replace mattresses or control units with other models or other brands. Otherwise, damage to the system m ay occur. Contact your supplier to get the correct replacement if nee[...]

  • Page 11

    SECTION 2—OPERATION Part No 1148138 11 MA80 Se rie s FIGURE 2.1 Installing the Mattress Replacement System Installing the Side R ails  WARNING Patient entrapment with bed side rails may cause injury or death. Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment. Follow the manufacturer’s instructions. Monitor patie[...]

  • Page 12

    SECTION 2—OPERATION MA80 Series 12 Part No 1148138 Connecting the Hose CAUTION Ensure that the hose connecting the control unit to the mattress i s routed such t hat it cannot be stepped on, kinked, squeezed or otherwise damaged. NOTE: For this pr ocedure, r efer to FIGURE 2.3. 1. Locate the hose at the foo t end of the mattress. 2. Locate the co[...]

  • Page 13

    SECTION 2—OPERATION Part No 1148138 13 MA80 Se rie s Connecting the Power Cord  WARNING DO NOT alter plug to fit a non-conforming outlet. Instead, have an electrician install a properly grounded outlet. Failure to use the correct plug and outlet can result in a potential safety hazard. CAUTION Ensure that the power cord of the control unit is [...]

  • Page 14

    SECTION 2—OPERATION MA80 Series 14 Part No 1148138 Using the Front Panel NOTE: For this pr ocedure, r efer to FIGURE 2.5. FIGURE 2.5 Using the Front Panel Power Butt on 1. T o turn the contro l uni t on or off, press and release the P ower butt on ( ). NOTE: Once the u nit is plugged in, an A MBER LED on t he contr ol unit is lit indic ating that[...]

  • Page 15

    SECTION 2—OPERATION Part No 1148138 15 MA80 Se rie s Pulse Butto n (MA80) 1. Press the Pulse button ( ) to T urn on Pu lse mo de and select one of four Pulse Times - 1, 3, 5 or 10 minutes. NOTE: The pulse tim es are 1, 3, 5 or 10 minutes. The pul se times indicate the time between each low pulse . For example, i f 5 minutes is selected, all the a[...]

  • Page 16

    SECTION 2—OPERATION MA80 Series 16 Part No 1148138 Static B utton 1. Press the Static button ( ) to select the static mode and maintain the mattress at constant pressure. NOTE: The Static LED is illumin ated GREEN. Firm/Soft Buttons 1. Select comfort pressure sett in gs by pressing Firm ( ) or Soft ( ) b uttons. • Soft Button - Pressing this bu[...]

  • Page 17

    SECTION 2—OPERATION Part No 1148138 17 MA80 Se rie s 5. P erform one of the following: • Cancel - Press the Fowler button to exit Fowler T ransmitter Setup wi thout linking to a transmitter . • Sav e - W ait 60 seconds w ithout pressing a key . Max Inflate B utton 1. Press the Max Inflate button ( ) to select the max i nflate mode and inflate[...]

  • Page 18

    SECTION 2—OPERATION MA80 Series 18 Part No 1148138 Powering Up the System NOTE: For this pr ocedure, r efer to FIGURE 2.5 on page 14. 1. T urn on the powe r to the system by pressing the P ow er button on the contro l uni t. NOTE: Once the button is released, a GREEN LED illuminates when the un it is on. Placing the Patient on the Ma ttress 1. Pr[...]

  • Page 19

    SECTION 2—OPERATION Part No 1148138 19 MA80 Se rie s Transferring Patient From/To a Gurney  WARNING ALWAYS engage the wheel locks of the bed and the wheel locks of the gurney before transferring the patient between the bed and the gurney. 1. Engage the wheel locks of the bed. Refer to the owner ’ s manual provided w ith the bed. 2. Engage th[...]

  • Page 20

    SECTION 2—OPERATION MA80 Series 20 Part No 1148138 FIGURE 2.6 Preparing for CPR Procedure Connector Cover Contro l Unit Connector Holes Hose Connector DETAIL “A” Control Unit DETAIL “B”[...]

  • Page 21

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING Part No 1148138 21 MA80 Se rie s SECTION 3—MAIN TENANCE AND TROUBLESHOOTING Cleaning the System  WARNING Before cleaning or disassembling the MA80 series, check the underside of the mattress folds for sharp objects such as scissors, needles, etc. These objects should be removed and discarded before p[...]

  • Page 22

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING MA80 Series 22 Part No 1148138 CAUT ION Laundry workers should always wash their hands before working with clean bedding. DO NOT overload the machine. DO NOT use chlorine bleach because it may damage the fabric coating. High air temperatures will damage the fabrics and void the Invacare warranty. i. Place[...]

  • Page 23

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING Part No 1148138 23 MA80 Se rie s Changing the Filter NOTE: For this pr ocedure, r efer to FIGURE 3.1. Clean the filter ev ery 5 months or whenev er it is di rty . 1. Remov e the two screws s ecuring the filter cover to the back of the contro l unit. 2. Remov e the filter . 3. W ash the filter with water a[...]

  • Page 24

    LIMITED WARRANTY PLEASE NO TE: TH E WAR RANTY B ELOW H AS BEEN DRAFTE D TO COMPLY W ITH FED ERAL LAW APPLICAB LE TO PR ODUC TS MANUFAC TURED AFTER JULY 4, 1975. This wa rrant y is e xtended o nly t o the or igin al pu rchaser who pur chases t his prod uct when new and unused from I nvacar e or a dealer. This warra nty i s not ext ended t o any o th[...]