Go to page of
Similar user manuals
-
Power Supply
Liebert Series 300
125 pages 3.81 mb -
Power Supply
Liebert PSA1000MT-120
2 pages 0.89 mb -
Power Supply
Liebert UPStation S3 Options
61 pages 0.97 mb -
Power Supply
Liebert UPStation GX
16 pages 0.29 mb -
Power Supply
Liebert UD600
6 pages 0.37 mb -
Power Supply
Liebert UPS
37 pages 1.07 mb -
Power Supply
Liebert VM18000
38 pages 1.18 mb -
Power Supply
Liebert GXT2-6000RT230
40 pages 3.43 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Liebert UPStation GXT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Liebert UPStation GXT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Liebert UPStation GXT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Liebert UPStation GXT should contain:
- informations concerning technical data of Liebert UPStation GXT
- name of the manufacturer and a year of construction of the Liebert UPStation GXT item
- rules of operation, control and maintenance of the Liebert UPStation GXT item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Liebert UPStation GXT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Liebert UPStation GXT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Liebert service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Liebert UPStation GXT.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Liebert UPStation GXT item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
P OWER P ROTECTION UPSta tion GXT ™ 6 kV A Maintenance Bypass U SER M ANUAL Transformerless with Configurable Output Distribution[...]
-
Page 2
[...]
-
Page 3
i T ABLE OF CONTENT S I MPORTANT S AFETY I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 G ENERAL D ESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 4
[...]
-
Page 5
1 IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual cont ains import ant instructions tha t should be c losely follow ed during installation and maintenance of this UPS tation GXT 6kV A Maintenance Byp ass. This product is designed fo r commercial / industr ial use only . Th is product is not intende d for us e with life support a[...]
-
Page 6
2 GLOSSARY OF SYMBOLS Risk of electrical shock Indicates W arning or Caution foll owed by import ant instructions Request s the user to consult the manual Equipment grounding conductor On Off i[...]
-
Page 7
3 GENERAL DESCRIPTION Congratulation s on you r purchase of Liebert's UPS tation GXT 6 kV A Maintenance Bypass. As with every Liebert product, we st and behind our quality . If you h ave any questions co ncerning th is Maintenance Bypass, plea se feel free to contact your local sales repres entative, or call the appropriate T echnical Supp ort[...]
-
Page 8
4 Maintenance Byp ass component layout UPS input switch (SW2) Output breaker (CB1) Configurable Output Distribution Bypass availability indicator (amber) UPS input power present (amber) Bypass switch (SW1) UPS output availability indicator (green) GND3 GND1 UPS output TB3 GND2 UPS input TB2 Utility input TB1 Hardwire output terminal block (TB4) 4 3[...]
-
Page 9
5 MAJOR COMPONENT S The following is a genera l description of ea ch component and it s functions. Please review this section carefully , as it will give you a better understan ding as to how the UPS tation GXT 6 kV A Maintenance Byp ass operates. B YP ASS S WITCH The Bypa ss Switch allows easy and rapid transfer of connected loads between the UPS [...]
-
Page 10
6 CABLE INST ALLATION W IRING P REP ARATION For access to terminal blocks, see diagrams on pag e 4. P OWER C ABLE I NST ALLATIO N Refer to the chart be low when selecting cable s: ! CAUTION Please read this section thoroughly before attempting to install wiring to this unit. Be sure that the unit is not connected to any AC ma ins power source or UP[...]
-
Page 11
7 Connecting Maintenance Byp ass to UPS t ation GXT6000T - 208 12 3 4 MAINTENANCE BYP ASS GND 1 208 VA C GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 132 132 13 4 L1 L2 L1 L2 +- Input Output Ext. battery Utility input L1 L2 NOTE GMB12 models are supp lied with an attached input power cord complete with L14-30 plug. GXT6000T - 208 Output T[...]
-
Page 12
8 Connecting Maintenance Byp ass to UPSt ation GXT6000T - 208X 12 3 4 MAINTENANCE BYP ASS GND 1 208V GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 13 2 13 2 13 4 L1 L2 N L1 +- Input Ext. battery Utility input L2 NOTE GMB12 models are supplied with an attach ed input power cord complete with L14-30 plug. Output TB4 120V 120V GXT6000T - 208 [...]
-
Page 13
9 Connecting Maintenance Byp ass to UPSt ation GXT6000T - 240X 12 3 4 MAINTENANCE BYP ASS GND 1 240V GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 13 2 13 2 13 4 L1 L2 N L1 +- Input Ext. battery Utility input L2 NOTE GMB12 models are supplied with an attached input power cord complete with L14 -30 plug. Output TB4 120V 120V GXT6000T - 240X[...]
-
Page 14
10 W ALL-MOUNT DIAGRAM D IAGRAM FOR A TT ACHING U NIT TO W ALL Use the following diagram, which sh ows the location and measurement s of factory-cut mounting slot s, when prepar ing to attach the GXT Maintenance Bypass to a wall. Liebert recommend s using 1/4-20 mounting scre ws. Rubber pads are supplie d for placing the Maintenance Byp ass on the [...]
-
Page 15
11 HARDWIRE OUTPUT OPTION This product is intended to be inst alled by a qualified electrician only . 1. COMPLETEL Y R EMOVE ALL P OWER FROM THE FRAME. If the Ma inte nance Bypass is connected to the UPS, disconnect external battery sup ply . 2. Remove the en d cover plate to access th e terminal block (see Accessing ter minal block below). 3. With[...]
-
Page 16
12 OPERATING PROCEDURES S T ART-UP AND INITIALIZATION Follow these steps in or der to start up the GXT 6kV A UPS while connected to the Maintenance Byp ass. O N M AINTENANCE B YP ASS 1. Set the Maintenance Bypa ss switch (SW1) to UPS position. 2. Close (position I ) UPS Input switc h (SW2). 3. Close (position I ) Output Circuit breaker (CB1). O N U[...]
-
Page 17
13 S PECIFICATIONS T ypical Tr ansfer T ime (to or from maintenance byp ass) < 6 milliseconds Input V oltage Nominal 208V AC or 240V AC T otal Current 30A max. Operating Ambient T emperature 0° to +40° C S t orage Ambie nt T em perature -20° to +60° C Dimensions, W x D x H, in (mm) 8.2 x 21.0 x 6.2 (209 x 534 x 158) Chassis Weight (no recept[...]
-
Page 18
[...]
-
Page 19
[...]
-
Page 20
The Comp any Behind the Product s With over a million installations around th e globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems fo r sensitive electronics: • Environmenta l systems—close-control air conditioning from 1 to 60 t[...]