Lochinvar Commercial Electric Water Heaters manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lochinvar Commercial Electric Water Heaters, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lochinvar Commercial Electric Water Heaters one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lochinvar Commercial Electric Water Heaters. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lochinvar Commercial Electric Water Heaters should contain:
- informations concerning technical data of Lochinvar Commercial Electric Water Heaters
- name of the manufacturer and a year of construction of the Lochinvar Commercial Electric Water Heaters item
- rules of operation, control and maintenance of the Lochinvar Commercial Electric Water Heaters item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lochinvar Commercial Electric Water Heaters alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lochinvar Commercial Electric Water Heaters, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lochinvar service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lochinvar Commercial Electric Water Heaters.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lochinvar Commercial Electric Water Heaters item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 INST ALLA TION AND SER VICE MANUAL SHP-I&S-02 COMMERCIAL ELECTRIC W A TER HEA TERS 52, 82, 1 19 Gallon, 9 kW - 54kW Input Models FIG . 1 Fr ont V iew V ertical Round Models Installation and serv ice must be performed by Qualified Serv ice P ersonnel Only . W ARRANTY Factory war ranty (shipped w ith unit) does not apply to units improperly ins[...]

  • Page 2

    2  W ARNING: CONTENTS W ar ranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Checking the Equipment . . . . . . . . . . . . . . . . . . . . . . . . .1 Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 3

    3 CODES The equipment shall be installed in acco rdance with those installation regulations in forc e in the local area where the installation is to be made. These shall be carefully followed in all cases. A uthor ities having jurisdiction shall be consulted befor e installations are made. I n the absence of such requir ements, the installation sha[...]

  • Page 4

    4 CLEARANCES FROM COMBUSTIBLE CONSTRUCTION FIG. 2 Clearances from Co mbustible Construction T ABLE - A CLEARANCES FROM COMBUSTIBLE CONSTRUCTION: Right Side - 0" Rear - 0" Left Side - 0" Fr ont - 18" (45cm) for serv ice access t o contr ols and heating elements T op - 12" (30cm) suggested for service access to piping and wat[...]

  • Page 5

    5 INLET AND OUTLET CONNECTIONS For ease of ser vice, install unions on the c old water inlet and hot water outlet of the water heater . The cold water inlet connection is located on the lo wer left front side of the water heater . A manual shutoff valve should be installed upstream on the cold wat er source as an isolation device. The hot water out[...]

  • Page 6

    6 ELECTRICAL CONNECTIONS All installation proc edures in volving electric power connection should only be performed by a trained, certified electricians. FIG. 4 Electric P ower Co nnections - Electr ical Control Pa n e l  W ARNING: W A TER HEA TER IS EQUIPPED FOR OPERA TION ON ONE V OL T AGE ONL Y . Check the rating plate on the front of the con[...]

  • Page 7

    7 JACKET ASSEMBL Y Outer Jack et - The out er jacket assembly is c onst ructed from hea vy gauge steel. The ext er ior surface is specially prepared and phosphat e coated to allow application of a multiple coat enamel paint pr ocess. This coating process insures a long life from the jack et assembly . ST ANDARD EQUIPMENT Y our commercial electric w[...]

  • Page 8

    8 A main power t er minal block is provided for field connection of the branch power supply to the electric water heater . All internal pow er circuits to the immersion heating elements are c onnected to the load side of the main terminal block. The line side of the terminal block has individual lug ty pe connections properly sized for the recommen[...]

  • Page 9

    9 The limit is reset by pushing the r ed reset button on the limit. Operation of the limit control usually indicates a major problem with the heating elements or temperature contr ol. Do not contin ue to push the reset m ultiple times. The problem causing the r eset to function must be found and corrected to insur e proper operation. The blank e t [...]

  • Page 10

    10  W ARNING: HAZARD OF ELECTRICAL SHOCK - Before opening the electrical access panel to adjust the thermostat or ser vicing the water heater , make sur e the electrical supply to the water heater is turned "OFF". Failure t o do this could result in death, serious bodily injur y or propert y damage. As a contr ol option, the water heat[...]

  • Page 11

    11  W ARNING: SHOULD O VERHEA TING O CCUR OR THE TEMPERA TURE CONTROLS F AIL TO SHUT OFF , TURN OFF OR DISCONNECT THE ELECTRICAL SUPPL Y A T THE MAIN POWER DISCONNECT , EXTERN AL TO THE APPLIANCE.  DANGER • W ater temperature over 125°F (51.7°C) can cause severe burns instantly or death from scald. • Children, disabled and elderly are a[...]

  • Page 12

    12 IMMERSION HEA TING ELEMENTS FIG. 14 Immersion H e ating Element  W ARNING: HAZARD OF ELECTRICAL SHOCK - Before opening the access panel t o remove or service the immersion heating elements, make sur e the elect rical supply to the water heat er is turned "OFF". F ailure to do this could result in death, serious bodily injur y or pro[...]

  • Page 13

    13 NOTE: The cold water supply m ust be left in the open position when the water heater is in use. 5. Check the near by hot water faucet t o verify that air is exiting the tank as it fills with water . Allow wate r to run until a constant flo w is obtained at the faucet. This will insure that all air is purged fr om the system.  CAUTION The powe[...]

  • Page 14

    14 SHUTDOWN PROCEDURE 1. T urn off the main electr ical power t o the water heater . If the power disc onnect point is out of sig ht, lock it in the open ("OFF") position and tag to prev ent unexpected application of power . 2. T urn the valve in the water heat er's cold water supply to the closed or "OFF" position. 3. T ur[...]

  • Page 15

    Scale accumulation in the bott om of the storage tank may be remo ved by turning off main power and draining the tank. Once all wate r is remo ved, the hand hole access can be remo ved. This w ill allow large ac cumulations of scale to be cleaned from the bottom of the tank. 15 Corrosion due to wat er chemistry gener ally shows up first in the hot [...]

  • Page 16

    Revision Notes: Revision 2 (ECO #C02870) reflects the addition of the scald char t on page 10. CP -5M-1/09-Printed in U.S.A. 16 7. Clean remaining gask et recess on eac h screw-in element flange. Do not reuse element gask ets. 8. Install a new gask et on each element. Install element into the tank opening where it was originally installed. Tighten [...]