Go to page of
Similar user manuals
-
Power Supply
MGE UPS Systems 3000 VA
34 pages 1.29 mb -
Power Supply
MGE UPS Systems Pulsar TM EX30
18 pages 0.2 mb -
Power Supply
MGE UPS Systems 12 kVA
32 pages 1.77 mb -
Power Supply
MGE UPS Systems FlexPDU 12 IEC
12 pages 0.86 mb -
Power Supply
MGE UPS Systems EX7
18 pages 0.21 mb -
Power Supply
MGE UPS Systems 6 kVA
32 pages 1.77 mb -
Power Supply
MGE UPS Systems Comet EX 11 RT 31
38 pages 1.53 mb -
Power Supply
MGE UPS Systems 3200RT
28 pages 0.51 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of MGE UPS Systems 12280 kVA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MGE UPS Systems 12280 kVA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of MGE UPS Systems 12280 kVA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of MGE UPS Systems 12280 kVA should contain:
- informations concerning technical data of MGE UPS Systems 12280 kVA
- name of the manufacturer and a year of construction of the MGE UPS Systems 12280 kVA item
- rules of operation, control and maintenance of the MGE UPS Systems 12280 kVA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MGE UPS Systems 12280 kVA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MGE UPS Systems 12280 kVA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MGE UPS Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MGE UPS Systems 12280 kVA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the MGE UPS Systems 12280 kVA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R Installation and user manual CleanWave 12÷280 kVA English[...]
-
Page 2
MGE-UPS CleanWave - Installation and user manual Page 2/13 Version 2.1 - 21/04/05 - (JME) INDEX 1. INTRODUC TION ..................................................................................................... 3 2. PRESENTA TION .................................................................................................... 3 2.1. General [...]
-
Page 3
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 3/13 Version 2.1 - 21/04/05 - (JME) 1. INTRODUCTION The present document is a user manual for the zero-sequ e nced filters CleanWave . It is intended to the persons responsi ble for the insta llation, the use and the maintenance of the filters. Each of these aspects is detailed in a[...]
-
Page 4
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 4/13 Version 2.1 - 21/04/05 - (JME) The IP21 version of the CleanWave filter appears as follows : 10 11 14 12 17 15 16 13 Fig. 3 10 Lifting rings 11 Upstream current display 12 Downstream current display 13 Removable top panel 14 Side panel for cabling 15 Ventilation grid 16 Removab[...]
-
Page 5
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 5/13 Version 2.1 - 21/04/05 - (JME) 2.2. R AN G E The following table summari ses the characteristics of the different pro ducts of the range (at 400V, 50/60Hz). Minimum sections 1 TYPE Power. I phase max I neutral Max Total losses max Phases Neutral (N) Earth (PE) ( PEN 2 ) [kVA] [A] [[...]
-
Page 6
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 6/13 Version 2.1 - 21/04/05 - (JME) 2.3. T ECHNICAL SPECIFICATIONS Standards Construction and safety : IEC-60439-1 Conception : IEC-60289, IEC-60727 IP rating Unprotected : IP00 Protected : IP21 Electrical specifications Frequency : 50 / 60Hz Nominal voltage between phase s : 400V +15% [...]
-
Page 7
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 7/13 Version 2.1 - 21/04/05 - (JME) 3. SAFETY CAUTION !!! The CleanWave ® filter exhibit s potentially lethal voltages. Like any electrical equipment, the installation and the use of the Clean Wave ® require some basic precautions . 3.1. I NTEGRATION IN HOUSING The IP00 filters are in[...]
-
Page 8
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 8/13 Version 2.1 - 21/04/05 - (JME) 4. ELECTRICAL ENGINEERING The electrical study for the implementation of a Clean Wave filter is very easy. The few instru ctions described in this document must ho wever be respec ted in order to ensure the safety and efficiency of the system. 4.1[...]
-
Page 9
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 9/13 Version 2.1 - 21/04/05 - (JME) 5. INSTALLATION AND STARTING 5.1. H AN D LI N G The filters are delivered on a wooden tray and c an e asily be moved with the help of a forklift. They can also be handled with the help of the lifting rings. 5.2. E LECTRICAL CONNECTIONS The electrical [...]
-
Page 10
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 10/13 Version 2.1 - 21/04/05 - (JME) The connections are the following : Terminal C onnection 1 L1 upstream 2 L2 upstream 3 L3 upstream 4N u p s t r e a m 5 N downstream 6 L1 downstream 7 L2 downstream 8 L3 downstream Earth Earth (PE) Table 9 The terminals must be properly tighten ed ac[...]
-
Page 11
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 11/13 Version 2.1 - 21/04/05 - (JME) 6. MAINTENANCE After installation, the CleanWave filter requires almost no mai ntenance. We only recommend a pe riodi c (e.g. annual) inspection. This inspection must be done with no voltage by a qualified technician . The working sequence is the[...]
-
Page 12
MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 12/13 Version 2.1 - 21/04/05 - (JME) 7. TROUBLESHOOTING Malfunction Solution No neutral current is measured downstrea m the filter. Is the filter energised ? Is breaker D1 closed ? Is the filter feeding the distorting load ? No neutral current is measured upstream the filter[...]
-
Page 13
MGE UPS SYSTEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R 140, Avenue Jean Kuntzmann ZIRST - Montbonnot St Martin 38334 - Saint Ismier Cedex - France www.mgeups.com[...]