MGE UPS Systems 18/280 kVA manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of MGE UPS Systems 18/280 kVA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MGE UPS Systems 18/280 kVA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of MGE UPS Systems 18/280 kVA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of MGE UPS Systems 18/280 kVA should contain:
- informations concerning technical data of MGE UPS Systems 18/280 kVA
- name of the manufacturer and a year of construction of the MGE UPS Systems 18/280 kVA item
- rules of operation, control and maintenance of the MGE UPS Systems 18/280 kVA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MGE UPS Systems 18/280 kVA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MGE UPS Systems 18/280 kVA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MGE UPS Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MGE UPS Systems 18/280 kVA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the MGE UPS Systems 18/280 kVA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R Installation and user manual CleanWave 18÷280 kVA English[...]

  • Page 2

    MGE-UPS CleanWave - Installati on and user manual Page 2/13 Version 2.1.4 – 15/01/2007 - INDEX 1. INTROD UCTION ..................................................................................................... 3 2. PRESEN TATION .................................................................................................... 3 2.1. General[...]

  • Page 3

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 3/13 Version 2.1.4 – 15/01/2007 - 1. INTRODUCTION The present document is a user manual for the zero-sequence d filters CleanWave  . It is intended to the persons responsible for the in sta llation, the use and the maintena nce of the filters. Each of these aspects is detailed in a[...]

  • Page 4

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 4/13 Version 2.1.4 – 15/01/2007 - The IP21 version of the CleanWave  filter appears as follows : 10 11 14 12 17 15 16 13 Fig. 3 10 Lifting rings 11 Upstream current display 12 Downstrea m cur rent display 13 Removable top panel 14 Side panel for cabling 15 Ventilation grid 16 Remov[...]

  • Page 5

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 5/13 Version 2.1.4 – 15/01/2007 - 2.2. R AN G E The following table summarises the chara cteristic s of the different products of the range (at 400V, 50/60Hz). Minimum sections 1 TYPE Power. I phase max I neutral Max Total losses max Phases Neutral (N) Earth (PE) ( PEN 2 ) [kVA] [A] [[...]

  • Page 6

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 6/13 Version 2.1.4 – 15/01/2007 - 2.3. T ECHNICAL SPECIFICATIONS Standards Construction and safety : IEC-60439-1 Conception : IEC-60289, IEC-60727 IP rating Unprotected : IP00 Protected : IP21 Electrical specifications Frequency : 50 / 60Hz Nominal voltage between phases : 400V +15% /[...]

  • Page 7

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 7/13 Version 2.1.4 – 15/01/2007 - 3. SAFETY CAUTION !!! The CleanWave ® filter exhibits potentially lethal voltages. Like any electrical equipment, the in stallation and the use of the CleanWave ® require some basic precautions . 3.1. I NTEGRATION IN HOUSING The IP00 filters are int[...]

  • Page 8

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 8/13 Version 2.1.4 – 15/01/2007 - 4. ELECTRICAL ENGINEERING The electrical study for th e implementation of a Clean Wave  filter is very easy. The few i nstructions described in this document must however be resp ected in order to ensure the safety and efficien cy of the system. 4.[...]

  • Page 9

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 9/13 Version 2.1.4 – 15/01/2007 - 5. INSTALLATION AND STARTING 5.1. H AN D LI N G The filters are delivered on a wooden tray and c an easily be moved with the help of a forklift. They can also be handled with the help of the lifting rings. 5.2. E LECTRICAL CONNECTIONS The electrical c[...]

  • Page 10

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 10/13 Version 2.1.4 – 15/01/2007 - The connections are the fo llowing : Terminal Connection 1 L1 upstream 2 L2 upstream 3 L3 upstream 4 N upstream 5 N downstream 6 L1 downstream 7 L2 downstream 8 L3 downstream Earth Earth (PE) Table 9 The terminals must be properly tightened according[...]

  • Page 11

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 11/13 Version 2.1.4 – 15/01/2007 - 6. MAINTENANCE After installation, the CleanWave  filter requires almost no mainten ance. We only recommend a periodic (e.g. ann ual) inspection. This inspection must be done with no voltage by a qualified technician . The working sequence i s the[...]

  • Page 12

    MGE UPS SYSTEMS CleanWave - Insta llation and user manual Page 12/13 Version 2.1.4 – 15/01/2007 - 7. TROUBLESHOOTING Malfunction Solution No neutral current is measured d ownstream the filter.  Is the filter energised ?  Is breaker D1 closed ?  Is the filter feeding the distorting load ? No neutral current is meas ured u pstream the filt[...]

  • Page 13

    MGE UPS SYSTEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R 140, Avenue Jean Kuntzmann ZIRST - Montbonnot St Martin 38334 - Saint Ismier Cedex - France www.mgeups.com[...]