Mitsubishi Electronics PCFY-P manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics PCFY-P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics PCFY-P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics PCFY-P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsubishi Electronics PCFY-P should contain:
- informations concerning technical data of Mitsubishi Electronics PCFY-P
- name of the manufacturer and a year of construction of the Mitsubishi Electronics PCFY-P item
- rules of operation, control and maintenance of the Mitsubishi Electronics PCFY-P item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics PCFY-P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics PCFY-P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics PCFY-P.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics PCFY-P item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. Air-Conditioners For Building Application INDOOR UNIT PCFY -P·NGMU- E[...]

  • Page 2

    2 s Before installing the unit, make sure you read all the “Safety precau- tions”. s Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system. Warning: Describes precautions that must be observed to prevent danger of injury or death to the user . Caution: Describes precautions th[...]

  • Page 3

    3 2. Installation location 3. Installing the indoor unit 3.1. Check the indoor unit accessories (Fig. 3-1) The indoor unit should be supplied with the following accessories (contained in the inside of the intake grille). Accessory name Q ’ ty 1 Washer 4 pcs 2 Pipe cover 1 pc Large size (For gas tubing) 3 Pipe cover 1 pc Small size (For liquid tub[...]

  • Page 4

    4 Fig. 3-8 Fig. 3-5 Fig. 3-6 Fig. 3-7 3.2.5. Indoor unit preparation (Fig. 3-5) 1. Install the suspending bolts. (Procure the W3/8 or M10 bolts locally .) Predetermine the length from the ceiling ( 1 within 100 mm). A Ceiling surface B Suspending bolt C Suspending bracket 2. Remove the intake grille. Slide the intake grille holding knobs (at two lo[...]

  • Page 5

    5 4. Installing the refrigerant piping 4.1. Precautions 4.1.1. For devices that use R22 refrigerant • Use the refrigeration oil applied to the flared sections. • Use C1220 copper phosphorus, for copper and copper alloy seamless pipes, to connect the refrigerant pipes. Use refrigerant pipes with the thicknesses specified in the table to the belo[...]

  • Page 6

    6 Installing procedures (Fig. 5-2) 1. Attach the joint socket 5 supplied with the unit to the drain port on the unit with a vinyl chloride adhesive. 2. Fasten the socket cover 6 supplied with the unit to the joint socket 5 . 3. Attach the field drain tubing (VP20/O.D. ø 26 PVC TUBE) to the joint socket 5 with a vinyl chloride adhesive. 4. Wrap the[...]

  • Page 7

    7 6.2. Power supply wiring (Fig. 6-2) Power cable size (diameter) : more than 1.6 mm (A WG14) Ground cable size (diameter) : 1.6 mm (A WG14) * Use copper supply wires. * Use the electric wires over the rating voltage 300 V . [Selecting non-fuse breaker (NF) or earth leakage breaker (NV)] T o select NF or NV instead of a combination of Class B fuse [...]

  • Page 8

    8 6.4. Setting addresses (Fig. 6-6) (Be sure to operate with the main power turned OFF .) • There are two types of rotary switch setting available: setting addresses 1 to 9 and over 10, and setting branch numbers. 1 How to set addresses Example: If Address is “3”, remain SW12 (for over 10) at “0”, and match SW1 1(for 1 to 9) with “3”.[...]

  • Page 9

    9 6. Electrical work F A H C D E G I I I H B B-1. B-2. Fig. 6-8 A A B TB 6 B Fig. 6-7 J H Fig. 6-9 6.7. Remote controller 1) Installing procedures (1) Select an installing position for the remote controller . (Fig. 6-7) The temperature sensors are located on both remote controller and indoor unit. s Procure the following parts locally: T wo piece s[...]

  • Page 10

    [...]

  • Page 11

    [...]

  • Page 12

    Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment. HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN Printed in Japan BG79U668H01[...]