Go to page of
Similar user manuals
-
Air Conditioner
Mitsubishi Electronics MUZ-GE18NA
48 pages 3.62 mb -
Air Conditioner
Mitsubishi Electronics MSY-GA24NA
32 pages 4.32 mb -
Air Conditioner
Mitsubishi Electronics MSZ-FD25VA
40 pages 5.83 mb -
Air Conditioner
Mitsubishi Electronics MSZ-A18YV
16 pages 0.84 mb -
Air Conditioner
Mitsubishi Electronics PURY-P72
387 pages 21.58 mb -
Air Conditioner
Mitsubishi Electronics PKH18FL
53 pages 1.41 mb -
Air Conditioner
Mitsubishi Electronics PKA-A36KA4.TH
32 pages 3.12 mb -
Air Conditioner
Mitsubishi Electronics PUHY-P72
326 pages 6.89 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics PEFY-P-VMH-E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics PEFY-P-VMH-E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics PEFY-P-VMH-E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Mitsubishi Electronics PEFY-P-VMH-E should contain:
- informations concerning technical data of Mitsubishi Electronics PEFY-P-VMH-E
- name of the manufacturer and a year of construction of the Mitsubishi Electronics PEFY-P-VMH-E item
- rules of operation, control and maintenance of the Mitsubishi Electronics PEFY-P-VMH-E item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics PEFY-P-VMH-E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics PEFY-P-VMH-E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics PEFY-P-VMH-E.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics PEFY-P-VMH-E item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
I Air -Conditioner s INDOOR UNIT PEFY-P-VML-E PEFY-P-VMS-E PDFY-P-VM-E PEFY-P-VMM-E PEFY-P-VMR-E-L/R PFFY-P-VLRM(M)-E PEFY-P-VMH-E PLFY-P-VLMD-E PFFY-P-VLEM-E GB PO HG SV CZ TR RU GR P NL I E F D SL OPERA TION MANU AL For saf e and correct use, please read this oper ation manual thoroughly before oper ating the air-conditioner unit. BEDIENUNGSHANDB[...]
-
Page 2
Remote controller -Button Fernbedienungs-T aste T ouche Commande à distance 1 [T emperatureinstellung]-T aste 2 [TIMER MENU]-T aste 3 [Modus]-T aste [MONITOR/SET]-T aste [BACK]-T aste 4 [TIMER ON/OFF]-T aste 5 [Luftklappe]-T aste [SET DA Y]-T aste [OPERA TION]-T aste 6 [Gebläsegeschwindigk eit]-T aste 7 [Richtungsklappensteuerung]-T aste 8 [Lüft[...]
-
Page 3
5 GB D F I NL E P GR RU TR A Hora actual/Hora do temporizador B Indicador de controlo centralizado C Indicador de temporizador OFF D Indicador de modo do temporizador E Visor do modo de funcionamento: COOL, DR Y , AU TO, F AN, HEA T F Indicador do modo de funcionamento G T emperatura predefinida H Indicador de corrente I Aba J V entila çã o K Sin[...]
-
Page 4
8 [Fig. A] A <PLFY -P125VLMD-E> <PDFY -P-VM-E> <PEFY -P-VML-E> <PEFY -P-VMM-E> A A <PLFY -P20~100VLMD-E> A A 12 A : Filter Filter Filtre Filtro Filtro Filter Filtro º›ÏÙÚÔ Фильтр Filtre : Air Flow Luftstrom Flux d’air Flujo de aire Flusso d’aria Luchtstroom Fluxo de Ar ƒÔ‹ ·¤Ú· Воздушны[...]
-
Page 5
9 A A <PEFY -P-VMH-E> <PFFY -P-VLEM-E, VLRM(M)-E> <PEFY -P-VMR-E-L/R> A A [Fig. A] <PEFY -P-VMS-E> 12 A A : Filter Filter Filtre Filtro Filtro Filter Filtro º›ÏÙÚÔ Фильтр Filtre : Air Flow Luftstrom Flux d’air Flujo de aire Flusso d’aria Luchtstroom Fluxo de Ar ƒÔ‹ ·¤Ú· Воздушный поток [...]
-
Page 6
10 GB D F E I NL P GR RU TR GB GB GB GB GB 1. Safety precautions s Before operating the unit, make sure you read all the “Safety precautions”. s “Safety precautions” lists important points about safety . Please be sure to follo w them. Symbols used in the text W arning: Describes precautions that should be observed to av oid the risk of inj[...]
-
Page 7
11 I GB D F E I NL P GR RU TR GB GB GB GB GB W arning: • Do not remove the fr ont panel or the fan guard from the outdoor unit when it is running. Y ou could be injured if you touch r otating, hot or high- volta ge par ts. • Never insert fingers, sticks etc. into the intakes or outlets, otherwise in- jury may result, since the fan inside the un[...]
-
Page 8
12 GB D F E I NL P GR RU TR GB GB GB GB GB PEFY-P40~140VMH, PFFY-P-VLEM, PFFY-P-VLRM PDFY-P100·125VM, PEFY-P100~140-VMM series F an speed : 2 stages Display: (Lo w) → (High) [PLFY-P125VLMD, PDFY-P20~80VM series] F an speed : 4 stages Display: (Lo w) → (Mid2) → (Mid1) → (High) [PLFY-P20~100VLMD, PEFY-P-VML, PEFY-P20~80-VMM, PEFY-P-VMR serie[...]
-
Page 9
13 I GB D F E I NL P GR RU TR GB GB GB GB GB 3.6. V entilation • The ventilation unit (O A processing unit or LOSSNA Y) automatically goes into operation when the indoor unit that is interlock ed with it goes into operation. • If the 8 [V entilation] button is pressed while the indoor unit is stopped, only the ventilator goes into operation. ?[...]
-
Page 10
14 GB D F E I NL P GR RU TR GB GB GB GB GB 6. T r oubleshooting Before y ou ask for repair service, chec k the following points: State of Machine It does not run. Air flows out but it does not cool enough or heat enough. Cool air or warm air does not come out. It runs briefly , but soon stops. The sound of the ex- haust and rotation of the motor ca[...]
-
Page 11
15 I GB D F E I NL P GR RU TR GB GB GB GB GB 7. Installation, transferring works, and chec king Regarding place f or installation Consult with your dealer f or details on installation and transferring the installation. Caution: Never install the air conditioner where there is a risk of leakage of flammab le gas. If gas leaks and accumulates ar ound[...]
-
Page 12
16 GB D F E I NL P GR RU TR GB GB GB GB GB P250VMH-E 28.0/31.5 470/1,250/1,120 100 72.0 110/220 130/260 50 52 P200VMH-E 22.4/25.0 470/1,250/1,120 100 58.0 110/220 130/260 42 44 3N~380-415V 50/60Hz P63VMH-E 7.1/8.0 380/750/900 45 13.5-19.0 50/100/200 100/150/200 32-38 36-41 P40VMH-E 4.5/5.0 380/750/900 44 10.0-14.0 50/100/200 100/150/200 27-34 31-37[...]
-
Page 13
17 I GB D F E I NL P GR RU TR GB GB GB GB GB P32VM-E 3.6/4.0 295 (58) 710 (790) 735 (600) 27 (5) 6.0-6.5-7.5-8.5 30/50/100 28-30-33-36 P ower source Cooling capacity*1/Heating capacity*1 kW Height mm Dimension*2 Width mm Depth mm Net weight kg Fa n Airflow rate (Lo w-Middle2-Middle1-High) m 3 /min External static pressure*4 P a Noise le vel (Low-Mi[...]
-
Page 14
18 GB D F E I NL P GR RU TR GB GB GB GB GB Notes: * Operation temperature of indoor unit. Cooling mode: 15 ° C WB - 24 ° C WB Heating mode: 15 ° C DB - 27 ° C DB *1 Cooling/Heating capacity indicates the maximum value at operation under the f ollowing condition. Cooling: Indoor : 27 ° C DB/19 ° C WB Outdoor: 35 ° C DB Heating: Indoor : 20 °[...]
-
Page 15
WT04883X02 HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Please be sure to put the contact address/telephone number on this manual before handing it to the customer. The product at hand is based on the following EU regulations: • Low Voltage Directive 73/23/EEC • Electromagnetic Compatibility Directive 89/ 336/E[...]