Go to page of
Similar user manuals
-
Indoor Fireplace
Monessen Hearth DIS33G
1 pages 0.43 mb -
Indoor Fireplace
Monessen Hearth Vent Free Firebox GCUF32C
1 pages 0.47 mb -
Indoor Fireplace
Monessen Hearth LLCF36
2 pages 0.25 mb -
Indoor Fireplace
Monessen Hearth Direct Vent BDV300C
1 pages 0.53 mb -
Indoor Fireplace
Monessen Hearth DFS42PVC
44 pages 6.24 mb -
Indoor Fireplace
Monessen Hearth IDV490PVC
40 pages 5.49 mb -
Indoor Fireplace
Monessen Hearth MDV600
1 pages 0.52 mb -
Indoor Fireplace
Monessen Hearth MCUF42D-R
1 pages 0.45 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Monessen Hearth CWC400, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Monessen Hearth CWC400 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Monessen Hearth CWC400. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Monessen Hearth CWC400 should contain:
- informations concerning technical data of Monessen Hearth CWC400
- name of the manufacturer and a year of construction of the Monessen Hearth CWC400 item
- rules of operation, control and maintenance of the Monessen Hearth CWC400 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Monessen Hearth CWC400 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Monessen Hearth CWC400, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Monessen Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Monessen Hearth CWC400.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Monessen Hearth CWC400 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
For use in U.S./Canada Underwriter's Laboratories Report No. MH7603 87D1504 12/09 Rev . 4 FP583A WMC 12/18/98 [...]
-
Page 2
2 CW C Series W oodbur ning Fireplace 87D1504 Read all instructions an[...]
-
Page 3
3 CW C Series W oodb ur ning Fir eplace 87D1504 50" (1270mm) 42" (1067mm) 35 Z v " (895mm) 46" (1 168mm) B, " (16mm) B, " (16mm) Zx " (13mm) Zx " 19 Cv " (502mm) 1 Cv " (45mm) 38" (965mm) 21" (533mm) 7 Cv " (197mm) 7 Z x " (191mm) Recessed Nailing Flange FP592A WMC42 SPE[...]
-
Page 4
4 CW C Series W oodb ur ning Fir eplace 87D1504 Insulation methods shown are optional for cold climate, not a requirement for unit operation. FPC554 Fireplace and chase parts identification. T ermination Cap Storm Collar Pan Flashing Draftstop T op Shield Surround Outlet Gril[...]
-
Page 5
5 CW C Series W oodb ur ning Fir eplace 87D1504 D RISE B G H B OFFSET C E 6 FT . G H A HEARTH FLOOR CHIMNEY SECTION CHIMNEY FLUE EXIT ELBOW FPC269 Chimney Requirements -typ. offset Circulating models 1/28/99 djt 30˚ OFFSET ELBOW 30˚ OFFSET ELBOW 30˚ RETURN ELBOW 30˚ RETURN ELBOW SKCS8 SUPPORT Example 1 Example 2 Example 3 ?[...]
-
Page 6
6 CW C Series W oodb ur ning Fir eplace 87D1504 Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run. [...]
-
Page 7
7 CW C Series W oodb ur ning Fir eplace 87D1504 The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with SK8 chimneys or 20' (6 m) with 3-wall chimneys[...]
-
Page 8
8 CW C Series W oodb ur ning Fir eplace 87D1504 Framing can be constructed before or after the fire- place is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1 and 2 for basic fireplace specifica[...]
-
Page 9
9 CW C Series W oodb ur ning Fir eplace 87D1504 Since you have already preplanned the chimney run, you should know exactly how the installation is to be accomplished - how much pipe is required, the number of elbows, if any , and type of termination to be used. REPORT TO YOUR DEALE[...]
-
Page 10
10 CW C Series W oodb ur ning Fir eplace 87D1504 Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level. The following table gives firestop spacer model n[...]
-
Page 11
1 1 CW C Series W oodb ur ning Fir eplace 87D1504 An outside air kit is installed in all CWC Series Fire- places. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors). If the [...]
-
Page 12
12 CW C Series W oodb ur ning Fir eplace 87D1504 FP593 SR/C 11/20/97 Installing firestop spacer . FP593 Nails (4) Firestop Spacer Joist Joist Firestop Spacer Nails (4) FP263 Attic shie[...]
-
Page 13
13 CW C Series W oodb ur ning Fir eplace 87D1504 Size of roof hole varies with the type of chimney ter- mination installed. Refer to installation instructions provided with the chimney termination to find correct size of roof hole. There must be an air space (1 Zx " - SK8; [...]
-
Page 14
14 CW C Series W oodb ur ning Fir eplace 87D1504 used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace open- ing to bottom of mantel shelf. All joints (top, bottom and sides) where wall or deco- rative facing material meets fireplace surround must be completely sealed with a noncombustible mat[...]
-
Page 15
15 CW C Series W oodb ur ning Fir eplace 87D1504 1. Manville - CERAFORM 126, K=.27, 1/2 inches thick 2. MHSC - EH2416, K = .458, 1 inch thick required. A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 24 for minimum dimensions and mount[...]
-
Page 16
16 CW C Series W oodb ur ning Fir eplace 87D1504 COMMON MA TERIALS AND F ACTORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (MHSC) R V alue is for 1/2 inch. * Units of K = BTU/SQ FT/HR /˚F/IN ** Thickness of Listed Material FP533ADD Addendum 6/1/99 djt 8/4/99 changed .2 to .1 one inch to 1/2 inch [...]
-
Page 17
17 CW C Series W oodb ur ning Fir eplace 87D1504 Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.1 1.2, are to be installed in this fireplace. If installing an unvented gas log set, refer to statement below: ?[...]
-
Page 18
18 CW C Series W oodb ur ning Fir eplace 87D1504 2-583 Parts page 3/2/99 djt 1 2 3 4 5 6 12 8 10 9 11 15 14a,b 17 16 18 OFF LOW 13 7 2 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ?[...]
-
Page 19
19 CW C Series W oodb ur ning Fir eplace 87D1504 The following accessories for this appliance are available from your local distributor . Should you need additional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361; Attn: T echnical Services. [...]
-
Page 20
20 CW C Series W oodb ur ning Fir eplace 87D1504 Round T op T ermination T op used to terminate chimney at roof. RL TSK8 (SK8) (Flashing not included.) Round T op T ermination - T op used to terminate chimney at chase. RL TSK8L Extended (SK8) (Flashing not included.) Flashing Metal finishing re[...]
-
Page 21
21 CW C Series W oodb ur ning Fir eplace 87D1504 Square Chase T ermination Square chimney cap used to terminate chimney SL TS8 through chase. Includes adapter . (Flashin[...]
-
Page 22
22 CW C Series W oodb ur ning Fir eplace 87D1504[...]
-
Page 23
23 CW C Series W oodb ur ning Fir eplace 87D1504 [...]
-
Page 24
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com[...]