Go to page of
Similar user manuals
-
Electric Heater
Napoleon Fireplaces GDS 28-P
24 pages 0.8 mb -
Stove
Napoleon Fireplaces EPA 1100C
16 pages 2.53 mb -
Printer Accessories
Napoleon Fireplaces GD82NT-T
32 pages 2.98 mb -
Indoor Fireplace
Napoleon Fireplaces BGD40-P
36 pages 2.36 mb -
Indoor Fireplace
Napoleon Fireplaces GVF40N
24 pages 5.01 mb -
Indoor Fireplace
Napoleon Fireplaces GT8P
22 pages 3.02 mb -
Gas Heater
Napoleon Fireplaces BGD42P
28 pages 1.29 mb -
Fire Pit
Napoleon Fireplaces GLVF24N
12 pages 5.05 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces GVFS20N, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces GVFS20N one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces GVFS20N. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Napoleon Fireplaces GVFS20N should contain:
- informations concerning technical data of Napoleon Fireplaces GVFS20N
- name of the manufacturer and a year of construction of the Napoleon Fireplaces GVFS20N item
- rules of operation, control and maintenance of the Napoleon Fireplaces GVFS20N item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces GVFS20N alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces GVFS20N, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces GVFS20N.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces GVFS20N item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 W415-0559 / 02.15.06 W415-0559 / 02.07.06[...]
-
Page 2
2 W415-0559 / 02.15.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. Installati[...]
-
Page 3
3 W415-0559 / 02.15.06 W ARNING • Under no cir cumstances should this heater be modified. • Pr ovide adequate v entila tion and combustion air . Pr ovide adequa te accessibility c learance f or servicing and oper ating the hea ter . Ne ver obstr uct the front opening of the heater . • If heater shuts of f , do not re-light until you pr ovide [...]
-
Page 4
4 W415-0559 / 02.15.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red[...]
-
Page 5
5 W415-0559 / 02.15.06 FOR YOUR SA TISF ACTION, THIS FIREPLACE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Maximum input is 23,000 BTU/hr for natural gas and propane. When the fi replace is installed at elevations above 2,000ft, and in the absence of specifi c recommendations from the local authority having jurisdiction, the certi?[...]
-
Page 6
6 W415-0559 / 02.15.06 MAINT AIN THESE MINIMUM CLEARANCES T O COMB USTIBLES: A. 4" B. 2" * C. 2" Pr ovide adequate v entilation and combustion air . Provide adequate accessibility clearance for servicing and operating the stove. Never obstruct the front opening of the stov e. As long as clearance to combustibles is kept within the re[...]
-
Page 7
7 W415-0559 / 02.15.06 BL O WER INST ALLA TION GAS INST ALLA TION 1. Install rigid black pipe, or 1/2" type L copper tubing with a shut-off valve to the stove. 2. Seal and tighten the gas line securely to a fl ex connector . DO NOT KINK FLEXIBLE CONNECTOR. 3. Check for gas leaks by brushing on a soap and water solution. Do not use open fl am[...]
-
Page 8
8 W415-0559 / 02.15.06 FINISHING 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by remov- ing the screws from the brackets located in the upper inside corners. 3. Slide the front straight up to remove. CAST FRONT INST ALLA TION AND REMO V AL 3 SCREWS BRACKET FRONT 2 SCREEN INST ALLA TION AND REMO V A[...]
-
Page 9
9 W415-0559 / 02.15.06 3. Place the hole in the underside of log #3 onto the locating screw , on the right side of the burner . The bottom branch of log #3 sits infront of, and against, the right end of log #2. 4. Reinstall the screen & front. LOG AND L OGO PLACEMENT In order to assemble the log set, the screen and cast front must be removed, s[...]
-
Page 10
10 W415-0559 / 02.15.06 • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour ’s phone. Follow the gas supplier ’s instructions. • If you cannot reach your gas supplier , call the fi re de- partment. When lighting and re-lighting, the gas knob cannot be turned fro[...]
-
Page 11
11 W415-0559 / 02.15.06 Air shutter adjustment must only be done by a qualifi ed gas installer! ADJUSTMENTS VENTURI ADJUSTMENT 1 . In order to properly clean the burner and pilot assembly , remove the logs exposing both assemblies. 2 . Keep the control compartment, logs, burner , air shutter opening and the area surrounding the logs clean by vacuu[...]
-
Page 12
12 W415-0559 / 02.15.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1. M ODEL & S ERIAL N UMBER OF FIREPLACE 2. I NST ALLA TION DA TE OF FIREPLACE 3.[...]
-
Page 13
13 W415-0559 / 02.15.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd. 29 19 12 20 5 6 19 16 4 21 18 24 1 2 3 23 7 10 22 11 26[...]
-
Page 14
14 W415-0559 / 02.15.06 Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve. Reconnect. - replace Oxygen Depletion Se[...]
-
Page 15
15 W415-0559 / 02.15.06 Pilot goes out while standing; Main burner is in ‘OFF’ position. Gas piping is undersized. - turn on all gas appliances and see if pilot fl ame fl utters, diminishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure. - check if supply piping size is to code. Correct all und[...]
-
Page 16
16 W415-0559 / 02.15.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES[...]