Go to page of
Similar user manuals
-
Hunting Equipment
Newcon Optik NVS 14-3AGBW
32 pages 0.87 mb -
Hunting Equipment
Newcon Optik DN310
10 pages 0.41 mb -
Hunting Equipment
Newcon Optik LRM 1800S
24 pages 0.82 mb -
Hunting Equipment
Newcon Optik NVS 14-3XT
32 pages 0.87 mb -
Hunting Equipment
Newcon Optik LRF MOD 4EC
40 pages 0.71 mb -
Hunting Equipment
Newcon Optik NVS 14-3GCS
32 pages 0.87 mb -
Hunting Equipment
Newcon Optik LRM 220SI
32 pages 0.91 mb -
Hunting Equipment
Newcon Optik NC 3-12X50
32 pages 1.1 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Newcon Optik LRM 1500M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Newcon Optik LRM 1500M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Newcon Optik LRM 1500M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Newcon Optik LRM 1500M should contain:
- informations concerning technical data of Newcon Optik LRM 1500M
- name of the manufacturer and a year of construction of the Newcon Optik LRM 1500M item
- rules of operation, control and maintenance of the Newcon Optik LRM 1500M item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Newcon Optik LRM 1500M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Newcon Optik LRM 1500M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Newcon Optik service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Newcon Optik LRM 1500M.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Newcon Optik LRM 1500M item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operation Manual LRM 1500M / LRM 1800S LASER RANGEFINDER MONOCULAR 105 Sparks Ave., Toronto, ON M2H 2S5, Canada[...]
-
Page 2
[...]
-
Page 3
IMPORTANT INFORMATION Read prior to activa tion You have just purc hased a sophisticat ed electro-opti cal device that em its invisible l aser radiat ion. To operate it properly, please, read this m anual carefully. NEVER direct laser beam at the eyes of pe ople or animals NEVER aim the unit at the Sun or bright so urces of light NEVER [...]
-
Page 4
Avoid eye exposure to direct laser beam or its close reflection Prevent bri ght light from foc ussing th rough the eyepiece Never aim the unit at highly reflective objects like mirrors and retroreflective surfaces, which are in close proximity to the laser rangefinder. This can lead to the permanent da mage of the photoreceiver incorpor[...]
-
Page 5
1 TABLE OF CONTENTS 1. BRIEF DESCRIPTIO N ............................................ 2 1.1 Principle of operation........................................... 2 1.2 Key Featur es ........................................................ 3 2. DEVICE APPE ARANCE ........................................ 4 3. DELIVERY S ET ..............................[...]
-
Page 6
2 CAREFULLY READ ALL THE I NSTRUCTIONS BEFORE USING THE UNIT! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANT Y AND MAY CAUSE INJURY! 1. BRIEF DESCRIPTION LRM 1500M / 1800S La ser Rangefinder Monocular is an advanced laser range finder system that enables instant distance and speed (1800S modification only) m easurement. The unit complies wi[...]
-
Page 7
3 Key Features Distance is displayed in meters or yards Original digital circuitry allows ranging through most types of glass, bushe s and other obs tacles Three channel optical solution (optical, laser a nd receiver) provides high accuracy Two reticle shapes: -¦- or Target quality display indicator assures that results are[...]
-
Page 8
4 2 3 4 5 6 7 1 8 2. DEVICE APPEARANCE Fig. 1. Front view 1 - Eyepiece 2 - Objective lens 3 - Laser em itter lens 4 - Receiver lens 5 - M (Mo de) button 6 - A (Acti on) but ton 7 - Body of the de vice 8 - Rubber g rip[...]
-
Page 9
5 Fig.2. Rear view 1 - Eyepiece 9 - Battery compartment cover 10 - Tripod socket 11 - Identification imprint 12 - Classification imprint, shown b elow 9 11 1 12 10[...]
-
Page 10
6 3. DELIVERY SET Standard delivery set LRM 1500M / 1800S is supplied in the following assembly: Qty LRM 1 9V Alkaline battery 1 Soft carrying c ase 1 Neck strap 1 Operation m anual 1 Warranty card 1[...]
-
Page 11
7 4. SPECIFICATION S Optics Magnificatio n Objective lens diameter Exit pupil diameter Field of view Type of coating 7x 25 mm 3.6 mm 8 Fully multi-coated optics Range Finder Laser Measuring range, LRM 1500M Measuring range, LRM 1800S Accuracy Meters/Yards display Last 10 readings recall Reticle Target quality indicator Class 1, eye safe, 905 nm[...]
-
Page 12
8 Speed Detector (LRM 1800S only) Measured spee d range 5-400 km /h Accuracy ±2 km/h Power Battery 9V 'Low Batte ry' indicato r Yes Environmental Operational temperature range Storage temperature range -25 / +50 o C (-13 / +122 o F) -45 / +65 o C (-49 / +149 o F) Mechanics Tripod thread Weight without battery Dimensi ons ¼” x 20 445 g[...]
-
Page 13
9 5. OPERATION INSTRUCTIONS 1 – Low battery indi cator 2 – Reticle (either -¦- or ) 3 – Units of measurem ent 4 – Measurement resul t 5 – Target q uality i ndicator 6 – Lase r active indicat or 7 – Setup m ode indicat or 8 – Ready mode indicat or 4 6 2 1 3 8 7 Fig. 3. Liquid Crystal Display as seen through the eyepiece 5[...]
-
Page 14
10 Changing b attery To install a battery: Slide the battery compartm en t cover down (9, Fig. 2) Install the battery observing polarity Don’t appl y superfluou s strength while push ing the bat tery inside the compartment. Close the compartment cove r If the battery does not fit the compartment easily, it means that polarity was [...]
-
Page 15
11 Measuring procedure To start the m easuring proced ure, remove t he lens co ver. Look through the eyepi ece (1, Fig. 1, 2) a nd ad just the focus by its rotating. When the Rangefi nder is off th e LCD is blank. To activate it press and hold A butto n (6, Fig. 1) for half a second. At star t the unit comes into Read y to Measure mode indicated by[...]
-
Page 16
12 Target reflectivity depends on its c olor, surface finish, size, shape, position in relation to the laser beam, etc. Bright target colors are more reflective tha n darks. A polished surface is m ore reflective than a rough one. L arger targets reflect better t han small ones. Ra nging a t arget perpe ndicular t o the laser beam provides better r[...]
-
Page 17
13 KMH/MPH : units of spee d measurement: km/hour or miles/hour ( 3, Fig.3) (LRM 1 800S only). Shape of the reticle: cross shape or rectangu lar sha pe (2, Fig.3). rEC1: Data Recall mode. It returns results of the last 10 measurements on the display. Measurement results are save d in on-board memor y. When you enter the Data Recall m ode, first m e[...]
-
Page 18
14 Additional di splay inf ormation Distance measuring procedure in cludes inst ant statistical processing of the package of si ngle measuri ng sessions. If there is more than one m easured targ et in the field of view, the embedded software estim ates the m ost prob able one by calculating the number of reflected pulses multiplied by the target st[...]
-
Page 19
15 6. STORAGE AN D MAINTENANCE The unit is a s ophisticated precisi on optical i nstrument equi pped with laser and electronics. Ther efore, it should be handled with due care. Keep away from direct sunlight. Avoid impacts, jolts, dust, moisture, and sharp changes of temperature. Do not use the device at tem peratures higher than 50 o C[...]
-
Page 20
16 7. TROUBLESHOOTING The ranging does not work . The display is transparent. Check the charge of the battery. Replace it if it is weak. Black dots are visible on LC D. Liquid Cryst al Display may have sm all black dots, scratc hes and other blemi shes inherited fro m the manufacturi ng process. These flaws are strictly regulated by num ber, area a[...]
-
Page 21
17 8. WARRANTY NEWCON warrants this product against defects in m aterial and workmanshi p for one y ear from the date of the ori ginal pur chase. Longer warranty is available, subject to the terms of the specific sales contract. Should your Newcon product pr ove to be defective during this p eriod, pleas e deliver the product securely packaged in i[...]
-
Page 22
18 9. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OPTIK product, consult this manual first. If the problem remains unresolved, c ontact our cust omer supp ort departm ent at (41 6) 663-6963 or toll f ree at 1-877-368-6666. Our operatin g hours are 9am-5pm, M onday - Friday , Eastern St andard Tim e. At no tim e should [...]
-
Page 23
19 10. QUALITY CERTIFICATE LRM 1500M LRM 1800S The unit indicated above has passed the quality inspection. Production date Serial number Quality Inspector Purchase date[...]
-
Page 24
NEWCON OPTIK Printed in Canada R1.TS – 02.12[...]