Go to page of
Similar user manuals
-
Hunting Equipment
Newcon Optik NC 3-12X50
32 pages 1.1 mb -
Hunting Equipment
Newcon Optik LRF MOD 4EC
40 pages 0.71 mb -
Hunting Equipment
Newcon Optik 15-45X60
8 pages 0.46 mb -
Hunting Equipment
Newcon Optik NVS 14-3GCS
32 pages 0.87 mb -
Hunting Equipment
Newcon Optik LRM 220SI
32 pages 0.91 mb -
Hunting Equipment
Newcon Optik NVS 14-3AG
32 pages 0.87 mb -
Hunting Equipment
Newcon Optik NVS 14-3AGBW
32 pages 0.87 mb -
Hunting Equipment
Newcon Optik NVS 14-3XT
32 pages 0.87 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Newcon Optik LRF MOD 4EC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Newcon Optik LRF MOD 4EC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Newcon Optik LRF MOD 4EC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Newcon Optik LRF MOD 4EC should contain:
- informations concerning technical data of Newcon Optik LRF MOD 4EC
- name of the manufacturer and a year of construction of the Newcon Optik LRF MOD 4EC item
- rules of operation, control and maintenance of the Newcon Optik LRF MOD 4EC item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Newcon Optik LRF MOD 4EC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Newcon Optik LRF MOD 4EC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Newcon Optik service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Newcon Optik LRF MOD 4EC.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Newcon Optik LRF MOD 4EC item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operation Manual LASER RANGE FINDER MODULE LRF MOD 4EC 105 Spa rks Ave., Toronto, ON, M2H 2S5 , Canada[...]
-
Page 2
ii[...]
-
Page 3
iii IMPORTANT INFORMATION Read prior to activation You have ju st purchased a s ophisticated ele ctro-optical de vice that emits i nvisible laser radiation. To operate it properly, please read this manual carefully. • NEVE R direct laser beam at the eyes of people or anim als • NEVE R aim the unit at the Sun or bri ght sources o f light • NEV[...]
-
Page 4
1 CONTENTS 1. BRIEF DESCRIPTIO N ............................................ 3 1.1 Principle of work ................................................. 4 1.2 Key Feat ures ........................................................ 4 2. DEVICE APPE ARANCE ........................................ 5 3. DELIVERY S ET .....................................[...]
-
Page 5
2 5.14 Additional display inform ation .......................... 22 6. BEST MEASURI NG TECHNIQUE ...................... 23 7. Interconnecti vity ..................................................... 25 7.1 Connecting to com puter ..................................... 25 7.2 Data output protoc ol .......................................... 25 7.3 Ad[...]
-
Page 6
3 CAREFULLY READ ALL THE I NSTRUCTION S BEFORE USING! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANT Y AND MAY CAUSE INJURY! 1. BRIEF DESCRIPTION The LRF Modules use the sa me electronics and optics as rangefinder m onoculars an d binoculars . These m odules can add various range finding capabilities in to host systems: distance & speed[...]
-
Page 7
4 Principle of work The Modules send invisible, eye safe laser pulses to the targ et. Pulses reflected from the target are captured and processed by the digital circuitry. The time-of-flig ht delay between the sent and received pulses allows calculating the distanc e to the target. A built-in digital compass/inclinometer of MOD 4EC measures target?[...]
-
Page 8
5 2. DEVICE APPEARANCE 1 – Communication connector 2 – Detachable eye-piece 3 – LRF cover 4 – Desiccator 5 – Optical window 6 – Detachable camera 5 3 1 2 Fig. 1. MOD 4EC general vi ew 4 6[...]
-
Page 9
6 1 – Low battery indi cator 2 – Reticle (either -¦- or ) 3 – Units of measurement 4 – Measurem ent result 5 – Target q uality indicat or 6 – Laser activ e indicator 7 – Gating i ndicator 8 – Setup m ode indicator 9 – Ready mode indicat or Fig. 2. Liquid Crystal Display view through the eyepiece 4 6 2 7 1 5 3 9 8[...]
-
Page 10
7 3. DELIVERY SET Standard delivery set The unit is supplied in the follo wing assembly: Qty LRF MOD 4E C 1 Eyepiece 1 USB camera 1 Compact disk with soft ware 1 Computer/power cable 1 Operation m anual 1 Warranty card 1 Hard case 1 Connectors: Data/power c onnector LEMO Push-P ull Connector FGG.0B.30 9.CLAD52 Data and powe r connectors can be m od[...]
-
Page 11
8 4. SPECIFICATIONS Range Finder Laser Measuring range Accuracy First, last and auto target selection Meters/Yards display Last 10 readings recall Reticle Target quality indicator Class 1, eye safe, 905 nm 16 m – 4, 000 m ± 1 m Yes Yes Yes -¦- or Yes Gating capability, m 100 - 7,000; 100 m step Speed measurement Measured speed ran ge 5 – [...]
-
Page 12
9 Interface RS 232 interface. Power External power requirement 9V DC, 300 m A The unit is fully operational when voltage is higher than 7V. A ‘ LOW BATTERY’ warning is displayed when voltage falls below 7.2V. Environmental Operational temperature range Storage temperature range -25 / +50ºC (- 13 / +122ºF) -45 / +65ºC (- 49 / +149ºF) Mechani[...]
-
Page 13
10 5. OPERATION INSTRUCTIONS Maximum distance Though ma ximum measurem ent distance dep ends on target reflectivity, we ather condit ions and othe r conditions , for most targets the unit will provide accurate rang ing for up to 3,000 meters. In good conditions a highly reflective targ et can be measured up to 4,000 meters. Target reflectivity depe[...]
-
Page 14
11 The correspondence betwee n the pr essing of t he buttons and t he signals sent via RS-232 is described i n Interconnectivity, cha pter 7. The rest of t his manual descri bes measurement p rocedures and setting m easurement param eters through pressing of t he buttons. Measurement procedure When the Module is off the LCD is blank. To activate it[...]
-
Page 15
12 Target selection logic On its way towards the ta rget, laser beam m ay reflect from various ob jects, thus decreasi ng ranging accuracy . The smal ler, the farther, and the less reflective is the target – the higher is the possibility of obtain ing an incorrect measurement. To improve accuracy the unit has a built-in target selection logic, wh[...]
-
Page 16
13 To activate the Scan ning regi me press and h old the A butto n in Ready mode. The unit will work in the Scanning regime while the A button is pressed. Scanning or Individual Measurement regimes are available for any selected mode of m easurement. When two param eters are measured in the Sc anning regime though both will be quickly displayed, th[...]
-
Page 17
14 2. In what units result of distance measurement is displayed: meters or y ards, degrees or m ils, km/ h or mph, 3. What reticle shape is visible: rectangular or crosshair, and 4. Which target is selected: first, last or most reflective (see the Target selection logic (5.4) for more details). The Setup mode is described in more detail below. The [...]
-
Page 18
15 Quick lin k to the Standa rd1 set of measurement param eters (display nam e: Std1 ), Quick lin k to Standa rd2 set of m easurement param eters (display nam e: Std2 ), Setup m ode (display name: COdE ), Gating mode (display name: GAt ), Data Recall mode (dis play name: rEc ), Memory Clearance m ode (display nam e: cLr ), ?[...]
-
Page 19
16 Note: On a spe cial request a menu of a particular unit can be simplified to show only required modes. Setup mode To modify t he Ready to Measure mode para meters: Enter the Set up mode. Wit h wor d Ready on the display press th e M button till display nam e COdE is displayed and pr ess the A button. Select the desir ed parameter m odifi[...]
-
Page 20
17 Mode Display name Distance Speed Azimuth Elevation Reticle Target selection logic Setup COdE Entrance into the Setup mode Cd 1 M m NC Cd 2 Y yd NC Cd 3 - ◦ Deg NC Cd 4 - Mils NC Cd 5 - ◦ Deg NC Cd6 - Mils NC Cd7 - m NC Cd 8 - yd Deg Deg -¦- Auto Cd 9 -¦- NC -¦- NC Cd 10 NC NC Cd 11 NC Last Cd 12 NC First Cd 13 NC Auto Cd 14 KMH NC[...]
-
Page 21
18 Mode Display name Distance Speed Azimuth Elevation Reticle Target selection logic Cd 16 Display test Cd 17 Compass calibration Gating GAt Entrance into gating mode Data Recall rEc Recalls last 10 measurement sets Data Clearance cLr Clears all recorded data Interface format -PC- or PLGr Selects PC or PLGR data format for output port Empty field m[...]
-
Page 22
19 Compass calibrat ion If the Module was exposed to a strong magnetic field or was not in use for a long time, the com pass accuracy may diminish. To bring the compass into working condition: Select Cd 17 in the Setup mo de Keeping the unit horizontally, perform one full rotation around vertical axis within ha lf a minute and then one full[...]
-
Page 23
20 Pressing the A button will activate shown on th e LCD communicat ion format. Gating mode In this mode the gating function is activated : user can set the minimal distance to the targ et; reflection from any object closer than the gating distance will be ignored. The Gating feature helps m easuring remot e targets in adve rse atmospheric and [...]
-
Page 24
21 Data Recall mode In the Data Recall mode results of the last 10 m easurements can be displayed. Measurement results are save d in on-board memory in sets depending on the paramete rs set for measuring , for instanc e, if only distance is measured - the set will consist of one number, if distance and azimuth are measured – the set will consist [...]
-
Page 25
22 Display test mode Selecting Code 16 in the Setup mode will cause all display segments and i ndicators to flash for 8 second s. Additional display inform ation Additional i ndication i s displaye d in the Ready to Measure mode: Y or M Indicates that distance is measured and displayed in yards or meters KMH or MPH Indicates that speed is measured [...]
-
Page 26
23 6. BEST MEASURING TECHNIQUE Laser range finder m odule measures distance by catchi ng a laser beam reflected from the targ et. Everyt hing that im proves reflection increases the measurement reliability and maximum range. 1. Aim at a surfac e on the targ et that is closest to the perpendicul ar to the laser beam. The closer you get – the stron[...]
-
Page 27
24 distance estimation to cut off all objects closer tha n the chosen one. Note: the Gating setting is remembered by the System until altered. Therefore, if you forget to turn the gating off, the next time you start measuring it can ignore th e desired object, if it is closer than the gating distance. Th e unit will display four dashes instead of t[...]
-
Page 28
25 7. Interconnectivity The unit supports RS-232 inte rface. Physical connection is performed through a connector specific to ea ch order. The default connectors are described i n Specificati ons. Connecting to computer The communication port must be initiated prior to connecting th e unit. Data is transm itted as a he x string code with fixe d bau[...]
-
Page 29
26 The data stri ng has the follo wing structure (in Hex): b1 b2 b3 E4h b5 E 4h 0Dh 0Ah, where: b1 – type of measurement; b2 – sign of measurement ( 1 – minus, 2 – plus); b3 – LSB of result; b5 – MSB of result Result of measurement = MSB * 256 + LSB In both standar d modes, when t h ree parameters a re measured, the module will generate[...]
-
Page 30
27 b11 – MSB of the res ult for the second type of measurement b15 – LSB of the resu lt for the third type of measurement b17 – MSB of the result for the third typ e of measurement Marker E4h is used to sepa rate num bers, 0Dh 0Ah – t o separate data sets. Type of measurem ent (bytes b1, b7, b13) can have the following value: 1 – Distance[...]
-
Page 31
28 S1 – first sym bol of the st atus menu S2 – second sy mbol of t he status menu S3 – third sy mbol of the status m enu or 21h S4 – 21h or 00h Examples of t he LRF menu o utput: Output, Hex Output, ASCII LRF menu position 53h 54h 31h 21h 0Ah 0Dh ST1! <LF><CR> Standard 1 43h 4Fh 44h 21h 0Ah 0Dh COD! <LF><CR> Code 47h[...]
-
Page 32
29 Output, Hex Output, ASCII LRF menu position 43h 31h 32h 21h 0Ah 0Dh C12! <LF><CR> Code 12 47h 32h 34h 21h 0Ah 0Dh G24! <LF><CR> Gating over 2400 m Output connector pin l ayout and cable di agram By default f or the output c onnector the m odule uses the connector as described in Sp ecifications. Thi s connector withstands[...]
-
Page 33
30 Figure 4. Cable diagram Connector and cable layou t can be modified for speci fic customer needs. GPS interconnectivity The Modules can transmit the acquired data to a GPS receiver using the sam e output connec tor and the PL GR/DAGR pro tocol.[...]
-
Page 34
31 Another cabl e is required a nd can be suppli ed as an option. To work with GPS, perform th e following steps: Switch to PLGr mode; Choose either Std1 or Std2 measuring mode; Connect the unit to and the GPS unit with the cable. For each measurement the GPS unit will display th e absolute coordinates of y our target. Note: If the modu[...]
-
Page 35
32 8. STORAGE AN D MAINTENANCE The unit is a s ophisticated p recision opt ical instrument equipped with laser and electronics. Ther efore, it should be handled with due care. • Keep away from direct sunlight. • Avoid impacts, jolts, dust, moisture, and sharp changes of temperature. • Do not use the device at tem peratures higher than 50 o C [...]
-
Page 36
33 9. TROUBLESHOOTING Ranging does not work. Display is transparent. Check the power supply. Ranging does not work. Display indicates results of the last measurement. Wait for 8 seconds until the display becomes transparen t, and press the Actio n button again. Black dots are visible on LCD. Liquid Cryst al Display m ay have small black dots, scrat[...]
-
Page 37
34 10. WARRANTY NEWCON warrants this product against defects in material and workmanshi p for one year f rom the date of the original pu rchase, but no m ore than 18 m onths from t he date of m anufacturing. Longer warranty is available, subject to the terms of the specific sales contract. Should your Newcon product pr ove to be defective during th[...]
-
Page 38
35 11. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OPTIK product, consult the enclo sed manual. If the problem remains unresol ved, contact our cust omer suppo rt department at (416) 663-6963 or toll free at 1-877-368-666 6. Our operating hours are 9am -5pm, Monday - F riday, Eastern Standar d Time. At no time sho uld [...]
-
Page 39
36 12. QUALITY CERTI FICATE MOD 4EC The unit has passed the quality inspection. Production date Serial number Quality Inspector Purchase date[...]
-
Page 40
NEWCON OPTIK ™ 2010[...]