Omron Healthcare BP652 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron Healthcare BP652, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron Healthcare BP652 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron Healthcare BP652. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron Healthcare BP652 should contain:
- informations concerning technical data of Omron Healthcare BP652
- name of the manufacturer and a year of construction of the Omron Healthcare BP652 item
- rules of operation, control and maintenance of the Omron Healthcare BP652 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron Healthcare BP652 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron Healthcare BP652, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron Healthcare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron Healthcare BP652.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron Healthcare BP652 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ESP AÑOL ENGLISH 7 series A utomatic W rist Blood Pr essure Monitor Model BP652 INSTRUCTION MANU AL[...]

  • Page 2

    2 TABLE OF CONTENTS Before using the Monitor Introduction ......................................................................................................... 3 Safety Information ................................................................................................ 4 Operating the Device .............................................[...]

  • Page 3

    3 INTRODUCTION Thank you for purchasing the OMRON ® BP652 IntelliSense ® Automatic W rist Blood Pressure Monitor . The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for people who frequently monitor their own blood pressure. Y our new digital blood pressure monitor uses the oscillometric method of blood pres- sur[...]

  • Page 4

    4 SAFETY INFORMA TION T o assure the corr ect use of the product, basic safety measur es should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . [...]

  • Page 5

    5 SAFETY INFORMA TION Do not use a cellular phone near the device. It may result in an operational failure. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.  Useonly1.5V “AAA”alkalinebatterieswiththisdevice.Donotuseothert[...]

  • Page 6

    6 BEFORE T AKING A MEASUREMENT T o ensure a reliable reading follow these recommendations: 1. A void eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. A void taking measurements during stressful times. 3.[...]

  • Page 7

    7 KNOW Y OUR UNIT Main Unit: Components: 2 “ AAA ” Alkaline Batteries Instruction Manual Quick Start Guide Date/Time setting ( ) button Display Wrist cuff Memory (MEM) button ST ART/STOP butt on User ID selection switch SET button Battery compar tment Date/Time setting ( ) button INTRODUCTION Thank you for purchasing the OMRON ® BP652 IntelliS[...]

  • Page 8

    8 UNIT DISPLA Y Positioning indicat or Diastolic blood pressure Irregular heartbeat symbol Memory symbol (Displayed when viewing values stored in memory) A verage v alue symbol (Refer to “Using the Memory Function” .) Movement error symbol (Displayed if you mo ve your body during the measurement) User ID symbol (A or B) (If “ GUEST ” is sel[...]

  • Page 9

    9 DISPLA Y SYMBOLS IRREGULAR HEAR TBEA T SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. Anirregularheartbeatrhythmisdenedasa rhythm that varies by less than 25% from the average rhy[...]

  • Page 10

    10 This is a general guideline because blood pressure depends on age and morbidity . A lower home blood pressure goal may be recommended for certain patients, including diabetic patients, pregnant women, and patients with renal failure. WARNING Contact your physicianfor specicinformation aboutyour blood pressure. Se[...]

  • Page 11

    11 BA T TERY INST ALLA TION CAUTION Useonly1.5V“AAA”alkalinebatterieswiththisdevice. 1. Press the hook on the bottom of the battery cover and lift the cover off in the direction of the arrow . 2. Install2“AAA”sizebatteriessothe+(positive)and- (negative) polarities match the polarit[...]

  • Page 12

    12 BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display , turn the monitor off and remove all the batteries. Replace with 2 new batteries at the same time. Long-life alkaline batteries are recommended. WARNING Ifbatteryuidshouldgetinyoureyes,immediatelyrinsewith plenty of c[...]

  • Page 13

    13 SET TING THE DA TE AND TIME Setthemonitortothecurrentdateandtimebeforetakingameasurementfortherst time. 1. TO ST ART THE SETTING Press the Date/T ime Setting button ( ) to adjust the date and time. Theyearashesonthedisplay . 2. SETTING THE YEAR Press the Date/T ime Setting butt[...]

  • Page 14

    14 4. SETTING THE DA Y Press the Date/T ime Setting button ( ) to advance by increments of one day . Press the Date/T ime Setting button ( ) to set the current day . Thehourashesonthedisplay . 5. SETTING THE HOUR The time is set using AM or PM. Press the Date/T ime Setting button ( ) to advance by increments of one hour . Press th[...]

  • Page 15

    15 SET TING THE ADV ANCED POSITIONING SENSOR (APS) Y ou can change the options for various settings on your monitor . Pressing the SET button to change a setting. Press the MEM button to select the options for that setting. Afterselectingasetting,presstheST ART/ST OPbuttontoconrmthesettingandturn the pow[...]

  • Page 16

    16 SETTING FOR RIGHT OR LEFT WRIST MEASUREMENT 1. While in the setting mode, press the SET button until the wrist symbol ( or ) appears on the display . NOTES: •Thedefaultsettingis“ ”. •Afteryouchoose“oFF”forthe Positioning indicator , the monitor skips this process. 2. Press the MEM button to sele[...]

  • Page 17

    17 IfthePositioningindicatoris“on1”or“on2”: on1: The buzzer sounds only when the monitor is in proper position. on2: The buzzer sounds a series of two short blips if your wrist is too far away from the measuring position, and beeps when your wrist is in the proper position. oFF: The buzzer will not sound. IfthePos[...]

  • Page 18

    18 CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. APPL YING THE CUFF ON THE LEFT W[...]

  • Page 19

    19 5. Fold the remaining part of the wrist cuff back out of the way . APPL YING THE CUFF ON THE RIGHT WRIST When taking a measurement using the right wrist position the cuff as shown in the illustration. Referto“SettingforRightorLeftW ristforMeasurement”. APPL YING THE WRIST CUFF[...]

  • Page 20

    20 The monitor is designed to take measurements and store the measurement values in memory for two people using USER ID A and USER ID B. The monitor can be used to takeasinglemeasurementusingtheGUESTmodearenotstoredinthememory . 1. Sitcomfortablyinachairwithyourfeetatonthe?[...]

  • Page 21

    21 T AKING A MEASUREMENT 5. Press the ST AR T/STOP button. All symbols appear on the display . Thecuffstartstoinateautomatically . Asthecuffinates,themonitorautomaticallydeterminesyouridealinationlevel. Thismonitordetectsyourbloodpressureandpulserateduringin?[...]

  • Page 22

    22 USING THE MEMOR Y FUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate for each user (A and B) in the memory . The monitor automatically stores up to 100 sets of measurement values (blood pressure and pulse rate) for each user (A and B). When 100 sets of measurement values are stored, the oldest rec[...]

  • Page 23

    23 USING THE MEMOR Y FUNCTION NOTES: • Thedateandtimearealternatelydisplayedwiththemeasurement values. •PresstheMEMbuttonrepeatedlytodisplaythenextvalues. •PressandholdtheMEMbuttontodisplaythevaluesfaster . 3. Press the ST AR T/STOP button to[...]

  • Page 24

    24 CARE AND MAINTENANCE T o keep your digital blood pressur e monitor in the best condition and protect the unit fr om damage, follow the directions listed below: Do not forcefully bend the cuf f. Do not fold tightly . Clean the monitor with a soft dry cloth. Do not use any abrasive or volatile cleaners. Do not attempt to clean the cuff. CAUTION Do[...]

  • Page 25

    25 ERROR INDICA TORS SYMBOL CAUSE CORRECTION Monitor could not detect pulse wave. T ake another measurement and remain still until the measurement is complete. Cuffunder -inated. Cuff not applied correctly . Remove the monitor from your wrist. Read“T akingaMeasurement”. W ait 2-3 minutes. T ake another measurement. Cuffover -i[...]

  • Page 26

    26 TROUBLESHOO TING TIPS PROBLEM CAUSES AND SOLUTIONS No power . No display appears on the unit. Replace both batteries with new ones at the same time. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low . Blood pressure varies constantly . Many factors including stress, time [...]

  • Page 27

    27 FC C ST A TEMENT Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The produc[...]

  • Page 28

    28 Y our BP652 IntelliSense ® Automatic W rist Blood Pressure Monitor , excluding the wrist cuff and batteries, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor . The above warranties extend only to the origi[...]

  • Page 29

    29 SPECIFICA TIONS Model: BP652 (HEM-6052-Z) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valve Rapid Air Release: Automatic exhaust valve Mea[...]

  • Page 30

    Omron Healthcar e, Inc. 1200 Lakeside Drive Bannockburn, IL 60015 www .omronhealthcare.com Copyright © 2010 Omron Healthcare, Inc. Made in China 5329415-9A[...]