Go to page of
Similar user manuals
-
Blood Pressure Monitor
Omron Healthcare HEM-780
28 pages 2.33 mb -
Blood Pressure Monitor
Omron Healthcare HEM-432C
20 pages 0.22 mb -
Blood Pressure Monitor
Omron Healthcare HXA-GCUFF-LLA
1 pages 0.62 mb -
Blood Pressure Monitor
Omron Healthcare HEM-712C
40 pages 0.74 mb -
Blood Pressure Monitor
Omron Healthcare BP755
1 pages 1.5 mb -
Blood Pressure Monitor
Omron Healthcare HEM-907XL
17 pages 1.39 mb -
Blood Pressure Monitor
Omron Healthcare BP652
30 pages 4.88 mb -
Blood Pressure Monitor
Omron Healthcare HXA-GCUFF-XLLA
1 pages 0.62 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omron Healthcare HEM-703CP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron Healthcare HEM-703CP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omron Healthcare HEM-703CP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omron Healthcare HEM-703CP should contain:
- informations concerning technical data of Omron Healthcare HEM-703CP
- name of the manufacturer and a year of construction of the Omron Healthcare HEM-703CP item
- rules of operation, control and maintenance of the Omron Healthcare HEM-703CP item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron Healthcare HEM-703CP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron Healthcare HEM-703CP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron Healthcare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron Healthcare HEM-703CP.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron Healthcare HEM-703CP item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Instruction Manual Automatic Digital Bl oo d Pr es su re M on it or Model HEM-703CP HEM-703CP-xxxx 0692581-7 A[...]
-
Page 2
1 Important CONTENTS I m p o r t a n t 1 Name and Function of Each Part 2 Preparations for Use 3 Instructions for Use ?[...]
-
Page 3
2 Name and Function of Each Part Air Jack Systolic Bood Pressure Display Diastolic Blood Pressure and Pulse Display Printing Paper Paper Cutter SPHYG/CLOCK Button ST ART Button PRINT / P APER FEED Button SET Button T ab Air Plug Air T ube MODE Selector Button Main Unit Cuff[...]
-
Page 4
3 Preparations for Use 1 How to insert the batteries Battery Cover 1 T ake off the battery cover at the back of the main unit by sliding it in the direction indicated by the arrow symbol Replacement • When the “Replace Batteries” symbol ( ) ashes during measurement, please replace the batteries with the new ones • When the batte[...]
-
Page 5
4 Preparations for Use 2 How to Set T ime and Date 3 Plug in and T urn on 1 When batteries are installed, the display shows PM 12:00 1 Insert the air plug into the air jack on the left side of the main unit correctly 2 When the SPHYG/CLOCK button is changed to the sphygmomanometer mode, all the LCD symbols are momentarily displayed?[...]
-
Page 6
5 Preparations for Use 4 How to Set the Printing Paper Please be sure not to print without inserting printing paper as it will shorten the life span of the printer head 1 Slide the plastic printer cover in the direction indicated by the arrow symbol and remove it from the main unit 4 Insert the printing paper in the installation section[...]
-
Page 7
6 Preparations for Use 5 Changing the Printer Ink Though not originally equipped with an ink roller , the HEM-703CP digital blood pressure monitor contains enough printer ink to last about two years when used once a day at normal room temperature When the ink on the print out becomes light and hard to read, purchase a replacement ink roller from[...]
-
Page 8
7 about 1 inch Artery no space Preparations for Use 6 Attach the Cuf f This cuff has eliminated the need for a microphone thereby lessening possible interference from vibrations and noise Fitting also has been made much easier through the widening of the artery oscillation detection area 1 Place the cuff on the left arm so that the air tub[...]
-
Page 9
8 Preparations for Use 7 Apply Pressure to the Cuf f 1 When you press the start button, the pump operates and pressure is applied When the pressure reaches 170mmHg, the pump stops automatically 2 When the appropriate pressure has been reached, the air is automatically released and the value on the display window starts to decrease A[...]
-
Page 10
9 Measurement Completed Alternate Display Blood Pressure Reading Display (for approx 3 seconds) Pulse Reading Display (for approx 15 seconds) *P: Stands for PULSE Preparations for Use 8 Blood Pressure and Pulse are displayed When the deation symbol begins to ash, the residual pressure in the cuff is then rapidly released 1 W[...]
-
Page 11
10 When Error Indication Symbols Appear The following special error symbols will appear in the display if the unit is being used incorrectly: ERROR SYMBOL CAUSE CORRECTION 1 Cuff underinated 1) Release air pressure in cuff 2) Wait 10 minutes before taking another reading 3) Repeat “Instructions for Use” steps except inate cuff 30 mm[...]
-
Page 12
1 1 Specications Power Source: Battery (four type “AA” dry cell batteries) 6V 4W Measurement Method: Oscillometric Method Display: Liquid Crystal Digital Display Measurement Range: Pressure: 0 ~ 280mmHg Pulse: 40 ~ 200/minute Accuracy: Pressure: within ± 3 mmHg Pulse: within ± 5% reading Pressure Detection: Capacitive Pressure Sensor In[...]
-
Page 13
12 This equipment generates and used radio frequency energy and if not installed and used properly , that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the speci[...]
-
Page 14
13 Limited One Y ear W arranty YOUR OMRON MODEL HEM-713C Digital Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of one year under normal use This warranty extends only to the original retail purchaser Should repair be needed, within the warranty period, ship the unit and receipt as proof of purchase pr[...]