Omron V600-HA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron V600-HA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron V600-HA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron V600-HA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron V600-HA should contain:
- informations concerning technical data of Omron V600-HA
- name of the manufacturer and a year of construction of the Omron V600-HA item
- rules of operation, control and maintenance of the Omron V600-HA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron V600-HA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron V600-HA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron V600-HA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron V600-HA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    2 Intelligent Flag I/II V600-HA Intelligent Flag I/II V600-HA Innov ative RFID Electronic Fla gs to Replace Mechanical Fla g and Kanban Systems • Doesn't need a program and can be used like a sensor . • Advanced line construction at minimal co st. • Sav es space. • Precise insta llation not required (T ransmission distance: 100 mm m ax[...]

  • Page 2

    Intelligent Flag I/II V600-HA 3 Note: The connector is not water proof. If there is a possibility that the connector ma y be exposed to water , k eep it inside the contr ol box. Be sure to use the connector together with t he separately sold interface cable. ■ Functions V600-HAR91/-HAR81 (Read-only type) Reads the 8-bit data (1 byte) of the set a[...]

  • Page 3

    4 Intelligent Flag I/II V600-HA ■ Sensor ■ Transmission Distance Specifications Recommended Combinations Note: 1. The specifications tak e fluctuations in ambient temperature and slight di fferences between products into account. 2. The read distance and write dista nce are the same. 3. Sensor Installation Conditions • V600-HS51:When flush-mo[...]

  • Page 4

    Intelligent Flag I/II V600-HA 5 System Configuration Programmable Controller, I/O terminal, B7A, CompoBus/S, etc. Sensor Controller V600-A6  R V600-A6  M Interface cable Amplifier Sensor Data Carrier Power supply 24 VDC Power supply 24 VDC Power supply 24 VDC V600 -HAR91/ HAR81 V600 -HAM91/ HAM81 V600 -HAR92 Connector connection Connector con[...]

  • Page 5

    6 Intelligent Flag I/II V600-HA Characteristic Data (Typical) ■ Transmission Range Combinations with the V600-HS51 Sensor Combinations with the V600-HS61 Sensor 0 –4 –8 4 8 4 8 X Y Y X 0 –4 –8 –12 4 12 4 8 81 2 X Y Y X 0 –5 –10 –15 5 10 15 5 10 15 X Y Y X 0 –5 –10 –15 5 10 15 X Y X 5 10 15 Y 0 –10 –20 –30 10 20 10 30 2[...]

  • Page 6

    Intelligent Flag I/II V600-HA 7 Combinations with the V600-HS63 Sensor X 0 –10 –20 –30 10 20 30 10 20 30 Y Y X 0 –10 –20 –30 –40 10 20 30 40 Y X 10 20 30 X Y 0 –10 –20 –30 –40 –50 10 20 30 50 40 Y X 10 20 30 40 50 Y X X 0 –10 –20 –30 –40 –50 10 20 30 50 40 Y X 10 20 30 40 50 Y X 0 –20 –40 –60 20 40 60 Y X 20 [...]

  • Page 7

    8 Intelligent Flag I/II V600-HA Combinations with the V600-HS67 Sensor ■ Transmission Time The transmission time ref ers to the time r equired for communications betw een the Sensor and the Data Carrier . It is used f or ca lculating the tra vel speed of the auto command. Example: Combinations with the V600-HA R91, V600-HS63, an d V600-D8KR04 Sen[...]

  • Page 8

    Intelligent Flag I/II V600-HA 9 Circuit Configuration V600-HAR91 V600-HAM91 Input Circuit Output Circuit V600-HAR92 Input Circuit Output Circuit V600-HAR81 V600-HAM81 Input Circuit Output Circuit Precautions ■ Cautions !Caution Be sure to house the V600-HA @ 91/-HA @ 81/-HA @ 92 together with their connectors and cable in c ontrol boxes when usin[...]

  • Page 9

    10 Intelligent Flag I/II V600-HA P ower Supply V oltage Do not impose any v oltage exceeding the rated v oltage range. Doing so , or applying alter nating curr ent (100 V AC) ma y cause the product to explode or b ur n. Load Short-circuiting Do not shor t-circuit the load c onnected to the product or connect to the power supply . Doing so may cause[...]

  • Page 10

    Intelligent Flag I/II V600-HA 11 Dimensions Note: All units are in millimeter s unless otherwise indicated. Amplifier V600-HAR91/-HAR81 * Enlarged Section of Mounting Hole T wo, mounting holes * Vinyl-insulated round cord 5.8-mm dia., 13-conductor cable, standard length: 0.5 m XG4E-2031 30û 4.4 5.5 30 21 17.5 28.3 36.3 61.8 89 8.2 98 68.5 55 30 80[...]

  • Page 11

    12 Intelligent Flag I/II V600-HA V600-HAM91/-HAM81 * Enlarged Section of Mounting Hole T wo mounting holes * Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m XG4E-2631 30˚ 4.4 5.5 30 21 17.5 28.3 36.3 61.8 52.3 44.3 89 8.2 98 68.5 75 55 30 80 35.2 500 mm 28.1 52.3 25 6 25 2-M4 89 ± 0.2 21 ± 0.2 Mounting Hole Dim[...]

  • Page 12

    Intelligent Flag I/II V600-HA 13 V600-HAR92 Sensor V600-HS51 V600-HS61 XG4E-2631 30˚ 4.4 5.5 30 21 17.5 28.3 36.3 61.8 44.3 89 8.2 98 68.5 75 55 30 80 35.2 500 mm 28.1 52.3 25 6 25 2-M4 89 ± 0.2 21 ± 0.2 * Enlarged Section of Mounting Hole T wo, mounting holes * Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m M[...]

  • Page 13

    14 Intelligent Flag I/II V600-HA V600-HS63 V600-HS67 Interface Cable V600-A6 @ R (for V600-HAR91/-HAR8 1)) 51.5 10 20 53 27 6 40 28 23 11 5 5 18 13 5 13.8 dia. T wo, 4.5-dia. mounting holes Vinyl-insulated round cord 6-mm dia (7/0.18-mm dia.), 8-conductor cable, standard length: 2 m Connector 4-R1 2-R5 Bushing P ower indicator (green) Case: ABS res[...]

  • Page 14

    Intelligent Flag I/II V600-HA 15 V600-A6 @ M (for V600-HAM9 1/-HAM81/-HAR92) Model L (m) V600-A60R/60M 2 V600-A61R/61M 5 V600-A62R/62M 10 Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.), 23-conductor cable, standard length: 2 m XG5M-2632-N Connector 7.6 10.6 37.6 30 30 ±5 20 ±5 20 ±5 20 ±5 L +100 0 330 +5 0[...]

  • Page 15

    1 6 Intelligent Flag I/II V600-HA Terms and Condi tions W ARRANTY , LIMI T A TIONS OF LIABILITY W ARRANTY OMRON’ s exclusiv e warranty is that the products are free from def ects in materials and work manship f or a period of one year (or other period if specified) f rom date of sale b y OMRON. OMRON M AKES N O W AR RANTY O R REPR ESE NT A TION, [...]