A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ResMed MIRAGE LIBERTY 61850/2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ResMed MIRAGE LIBERTY 61850/2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ResMed MIRAGE LIBERTY 61850/2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ResMed MIRAGE LIBERTY 61850/2 should contain:
- informations concerning technical data of ResMed MIRAGE LIBERTY 61850/2
- name of the manufacturer and a year of construction of the ResMed MIRAGE LIBERTY 61850/2 item
- rules of operation, control and maintenance of the ResMed MIRAGE LIBERTY 61850/2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ResMed MIRAGE LIBERTY 61850/2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ResMed MIRAGE LIBERTY 61850/2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ResMed service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ResMed MIRAGE LIBERTY 61850/2.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ResMed MIRAGE LIBERTY 61850/2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Global leaders in sleep and respiratory medicine www .resmed.com Mirage Liber ty™ FULL F ACE MASK User Guide English 61850/2 07 04 MIRAGE LIBER TY USER AP A C ENG 61850 61850r2 cover.qxp 3/04/2007 4:39 PM Page 1[...]

  • Page 2

    ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA ResMed (UK) Ltd (EU Authorized Representative) 65 Milton Park Abingdon Oxfordshire OX14 4RX UK ResMed Offices Australia, Austria, Brazil, Finland, France, Germany , Hong Kong, Japan, M[...]

  • Page 3

    A Mask parts M i r a g e L i b e r t y ™ Mouth cushion Mask frame Ports cap Val ve Exhaust vents Upper straps Lower straps Lower clip B Fitting the mask 1 2 1 2 3 4 5 C Disassembling for cleaning 3 4 5 6 7 © 2007 ResMed Ltd. © 2007 ResMed Ltd. Inlet tube Swivel Nasal pillows Valve clip Right upper clip Lower clip Headgear parts Elbow Left upper[...]

  • Page 4

    D Reassembling the mask 1234 7 8 Mirag e Liberty F ull Face Mask Illustrations Sheet Note : F or complete instructions, please read the text section in conjunction with the illustrations on this sheet. Component of: 61850/2 5 E Reassembling the headgear 1 © 2007 ResMed Ltd. 9 6 © 2007 ResMed Ltd. 2 61850r2 illo sheets.qxp 3/04/2007 4:38 PM Page 2[...]

  • Page 5

    Engli sh 1 Mirage Liber ty™ FULL FAC E MAS K T hank y ou fo r c hoosin g R esMed ’ s Mirage Liberty . Th e Mirage L iberty is a ful l face m ask th at comb i nes na sa l pi ll ows and a mou th cu shi on , c rea t ing a ma sk tha t is bo th u nob trusi ve and ea sy to us e wit hou t comp rom i sing se al, st a bil it y and co mfo rt. The mask in[...]

  • Page 6

    2 • An y suppl emental oxy gen flow must be turne d of f when the flow generato r is not operati ng, so th at unus ed o xygen d oes not accu mulate w ithin the flow generat or enc losure and create a risk of fire. • At a fixe d flow rat e of sup plementa l ox ygen flo w , the inha led o xygen conce ntration w ill vary , depend ing on the pressu[...]

  • Page 7

    3 Engli sh 5 T o tighte n or lo osen th e hea dgear s traps, pe el the V elc ro ® t ab of f the headg ear an d repos ition it. Gently and ev enly adj ust the upp er headge ar straps ( B-3 ), then t he lo wer stra ps ( B-4 ). Alterna te the a djustm ent of e ac h set of s traps unti l the y are com fo rt abl e and firm an d so that t he u pper head[...]

  • Page 8

    4 Note: You c an deta ch th e elb ow from the mask frame an d lea ve the mask on you r face. You ma y prefe r to do this w hen bri efly s toppin g thera py, for examp le to go to the bathroom. Disassembling the Mask See sec tio n C on th e illu str ations sh ee t. 1 Unclip the up per hea dgea r clips from th e frame ( C-3 ). 2 Careful ly pull th e [...]

  • Page 9

    5 Engli sh If the v ent requ ires c leani ng, use a sof t bris tle br ush. Rinse all com ponent s w ell w ith dri nking quality wa ter and al lo w them to a ir dr y out of direct su nlight. Weekly Handw ash the he adgea r b y gen tly r ubbing i n w arm ( 30°C) w a ter us ing m ild soa p or dilute d dish w ashing de tergent. Rinse the headge ar w e[...]

  • Page 10

    6 5 As sembl e th e elbo w ass embly : a P ush the t ab of the v alv e u p throug h the s lot in the v alv e clip ( D-7 ). Ens ure that the v alv e loc ks into the slot. b F eed the flap o f the v a lv e throu gh the slot i n the el bo w ( D-8 ). c Press th e valve cl ip ont o the el bow unt i l you hea r bot h s ide s cl ic k int o plac e ( D-9 ).[...]

  • Page 11

    7 Engli sh T r oubl eshooting P rob lem P ossible r eas on P oss ible solut ion Mask won ’t seal p roper ly or is un comf ortable Mouth cushio n o r pillows m ay be dirt y . Clean ma sk accord ing to instructions in “ Cle aning th e Mask in the Ho me ” . Mask may hav e been fit ted incorrectly . Carefully fo llow instruction s in “F it ting[...]

  • Page 12

    8 T ec hnical Specificat ions Note: The mask system does no t co nt ai n latex, PV C or DE HP ma ter ial s. Pre ssu r e– Fl ow C u rve Note: As a resu lt of manuf act uring v ar iation s, the v ent flo w ma y v ar y f rom that indi cated in the graph. Dead Sp ace Inf orm ation De ad sp ace i s the empty v olume of t he mas k up to the el bo w . T[...]

  • Page 13

    9 Engli sh Mask s ize s (e x clu des in let t ube and h eadge ar) S ymbols System and Pa ckaging User Gui de si ze widt h ( mm) he ight (mm) depth (mm) small 1 1 0 92 95 l a r g e 1 10 10 0 10 0 Caution , consult accomp any ing do cumen ts L ot nu mb er P art num be r/P roduc t co de No latex Humidity limit ation T emp era t ur e li mitation Manu f[...]

  • Page 14

    10 Or der ing Infor mat ion Limit ed W ar r anty R esM ed w ar rants tha t y our R esM ed mas k sy stem , includ ing it s comp onents : mas k frame, cus hion, head gear , t ubing a nd other ac cess ories (“P rodu ct”) sh all be fre e from d ef ects in materi al an d w orkm anshi p f or a p eriod o f ninety (90) da y s from the date of purc hase[...]