Go to page of
Similar user manuals
-
Home Security System
Samsung SCV-2080R
19 pages 6.73 mb -
Home Security System
Samsung SSA-P400T
27 pages 2.58 mb -
Home Security System
Samsung SSA-P102T
24 pages 1.71 mb -
Home Security System
Samsung Scc-C6475
1 pages 0.25 mb -
Home Security System
Samsung SSA-S1000
16 pages 0.57 mb -
Home Security System
Samsung SSA-R1001
1 pages 0.17 mb -
Home Security System
Samsung SSA-S4001
1 pages 0.15 mb -
Home Security System
Samsung SPD-2200
29 pages 2.37 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Samsung SSA-P102, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Samsung SSA-P102 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Samsung SSA-P102. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Samsung SSA-P102 should contain:
- informations concerning technical data of Samsung SSA-P102
- name of the manufacturer and a year of construction of the Samsung SSA-P102 item
- rules of operation, control and maintenance of the Samsung SSA-P102 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Samsung SSA-P102 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Samsung SSA-P102, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Samsung service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Samsung SSA-P102.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Samsung SSA-P102 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Access Control Panel user manual SSA-P102 SSA-P102T imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.com[...]
-
Page 2
2_ safety information safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this u[...]
-
Page 3
English _ 3 SAFETY INFORMATION Keep out of direct sunlight and heat radiation sources. It may cause fi re. Install it in a place with good ventilation. Avoid aiming the controller directly towards extremely bright objects such as sun. Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall[...]
-
Page 4
4_ contents contents PRODUCT INTRODUCTION 5 5 FeatureS 6 What’s included 9 Cable Selection INSTALLATION AND EXTERNAL CONNECTION 10 10 Connecting the termination resistor and diode 11 Earth-grounding the communication cables 12 Power, Reader, and I/O Connection 15 Communication Line Connection INITIALIZATION 19 19 System Initialization 19 Reader I[...]
-
Page 5
English _ 5 PRODUCT INTRODUCTION FEATURES This is a state-of-the-art single door access controller device that provides a high level security system in an affordable price, meeting the needs in the security industry. With its user-friendly interface, this product enables user manipulation easy and simple for whatever you want to perform in a high l[...]
-
Page 6
6_ product introduction product introduction Time Scheduling You can specify a time range during which a specifi c operation is performed. You can specify a specifi c time range for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time ranges for a day, ranging from Monday to Sunday including [...]
-
Page 7
English _ 7 PRODUCT INTRODUCTION Main Board 1 Fixing Hole Used to attach SSA-P102 to the closure using a metal supporter. (Ensure that you use the metal supporter to prevent the EMI.) 2 2Pin DIP Switch Used to set the type of a connected reader to either 26bit Wiegand or 34bit Wiegand. 3 8Pin DIP Switch The device address and communication speed sp[...]
-
Page 8
8_ product introduction product introduction 10 Input #3 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. 11 Input #2 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. (connected to the Door Contact Sensor.) All other sensors are not allowed. 12 Input #1 Input Port: The fl as[...]
-
Page 9
English _ 9 PRODUCT INTRODUCTION CABLE SELECTION Item Cable Type 1 DC 12V Product Power This product Belden #9409, 18 AWG 2 Conductor, Unshielded 2 Reader (Power and Data) External Reader This product Belden #9512, 22 AWG 4 Conductor, Shielded Belden #9514, 22 AWG 8 Conductor, Shielded 3 Door Contact Sensor Exit Button Sensor Input Input ?[...]
-
Page 10
10_ installation and external connection installation and external connection CONNECTING THE TERMINATION RESISTOR AND DIODE Termination Resistor A resistor is inserted for matching the line’s impedance to prevent distortion and reduction in RS-422 or RS-485 long distance data communications, which is referred to as termination resistor. Note that[...]
-
Page 11
English _ 11 INSTALLATION AND EXTERNAL CONNECTION EARTH-GROUNDING THE COMMUNICATION CABLES We recommend you to use a proper grounding system for the communication cables. The best grounding method is to earth-ground the shield wire of the communication cable. However, the earth-grounding of the communication cable is not easy at all, and it also ca[...]
-
Page 12
12_ installation and external connection installation and external connection POWER, READER, AND I/O CONNECTION Power Connection Check the location of the power port. - Connect the plus (+) line of DC 12V to the corresponding port (+12V). - Connect the plus (-) line of DC 12V to the GND (-) port. Reader Connection - You can safely use other power s[...]
-
Page 13
English _ 13 INSTALLATION AND EXTERNAL CONNECTION Input Connection - The Input #1 and Input #2 ports have the Exit button and the Door Contact Sensor installed, while Input #3 to Input #5 can be confi gured to your preference. - Exit Button Connection Connect one line of the Exit button to IN 1. Connect the other line of the Exit button to GND. - [...]
-
Page 14
14_ installation and external connection installation and external connection Output Connection - According to the operation mode, the Door Lock type is classifi ed in two: NC (Normal close) and NO (Normal Open). Make the connection as appropriate. - To prevent a risk of voltage surge during the lock operation, it is recommended to use the bypass [...]
-
Page 15
English _ 15 INSTALLATION AND EXTERNAL CONNECTION COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: Connect RS-232-TX to pin #2 of the 9-pin connector. Connect RS-232-TX to pin #3 of[...]
-
Page 16
16_ installation and external connection installation and external connection RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: Connect RS-422-TX(-) to the RX(-) port of the converter. Connect RS-422-TX([...]
-
Page 17
English _ 17 INSTALLATION AND EXTERNAL CONNECTION RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications with SSA-P102. - Follow the guidelines below to make connection between devices. Connect TX(-) of one device to TX(-) of other one. Connect TX(+) of one device to TX(+) of[...]
-
Page 18
18_ installation and external connection installation and external connection TCP/IP Communication Port Connection 1) TCP/IP Communication Connection SSA-P102T is required to establish TCP/IP communications. 2) Cabling Connect the LAN cable to the TCP/IP RJ-45 jack as shown. Connect the RJ45 jack of the unit to the RJ45 plug, the LAN cable of the n[...]
-
Page 19
English _ 19 INITIALIZATION Initialization SYSTEM INITIALIZATION Initializing the system using the Initialize switch Apply the power and initialize the system by using the initialization switch. Locate the Initialize switch ( ) on the upper right corner and press both switches simultaneously. Pressing both of the switches at the same time for about[...]
-
Page 20
20_ initialization initialization BOARD ID SETTING Each device in the multi-serial communication connection is assigned with a unique number to identify each other. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF. Each switch has a unique value, and the board ID is the sum of the values of the switches. Yo[...]
-
Page 21
English _ 21 TROUBLESHOOTING troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact the SAMSUNG Customer Service near you. Problem Action Can I specify RF only or RF+P/W mode differently according to the card? 1) It is not available. 2) The mode i[...]
-
Page 22
22_ troubleshooting troubleshooting The reader reads a card normally but no reaction is made to SSA-P102 or an irrelevant card number is displayed. 1) Check the power source of the reader. (Check if the LED indicator of the reader is blinking when it has read a card.) 2) Check if the reader works properly. (Disconnect the reader from the system and[...]
-
Page 23
English _ 23 product specifi cations PRODUCT SPECIFICATIONS Item SSA-P102 SSA-P102T Users 10,000 ~ 50,000 Users (Default: 10,000) Event Buffer 50,000 ~ 100,000(Default: 50,000) Power / Current DC 12V / Max.120mA Reader Port 2ea : 26bit/ 34bit Wiegand(Selectable), 4 / 8bit Burst for PIN Door Open Time 00~99 Sec. (Default 3Sec.) Communication RS232 [...]
-
Page 24
AB82-02555A Correct disposal of batteries in this product (Applicable in the European Union and other European countries with separate battery return systems.) This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life. Where mar[...]