Schneider Electric iFBZ manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Schneider Electric iFBZ, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Schneider Electric iFBZ one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Schneider Electric iFBZ. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Schneider Electric iFBZ should contain:
- informations concerning technical data of Schneider Electric iFBZ
- name of the manufacturer and a year of construction of the Schneider Electric iFBZ item
- rules of operation, control and maintenance of the Schneider Electric iFBZ item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Schneider Electric iFBZ alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Schneider Electric iFBZ, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Schneider Electric service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Schneider Electric iFBZ.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Schneider Electric iFBZ item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    [...]

  • Page 2

    [...]

  • Page 3

    The world's first EOCR with built-in ZCT (bottom hole & terminal type) will save space, time and wiring through unique development design during installation. with compact size, possible to be applied to various panel size. the protection function added for high groud fault current. most suitable for low frequency circumstance (5Hz~, Invet[...]

  • Page 4

    Applications Building Office, commercial business, residence, school, hospital Industrial facilities Petrochemical, electronic, glass, steel, semiconductor, chemical, medicine, cement, paint[...]

  • Page 5

    Public institutions Gas, water supply and drainage, airport, train, port Control power ● 24 VDC ● 85~260 VAC/DC, 50/60 Hz Composition by function ● Earth Fault ● i3BZ, iFBZ (with Modbus RS-485) ● 3BZ2, FBZ2 (without Modbus RS-485) Contact contact ● A-Type ● 95-96(b), 97-98(a) : OL ● 57-58(a) : GR ● C-Type ● 95-96(b), 97-98(a) : [...]

  • Page 6

    6 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Earth fault detection by built-in ZCT Multifunctional motor protection for rated motor currents up to 80A (Definite Overcurrent protection) : Over [...]

  • Page 7

    7 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Item Operating Condition & Setting Range Operation Time Over Current (oc) Load current(In) exceeds threshold(Is) Definite(Def) : 0.2~30s Adjust[...]

  • Page 8

    8 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Over Current Rated Setting Range(A) Definite TCC : 0.5~80A Inverse & th TCC : 0.5~32A *** CAUTION : Do not use any external CT Under Current Ra[...]

  • Page 9

    9 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Time-current characteristic cur ve 2. Definite characteristic 3. Inverse thermal characteristic (0.5~32A) 1. Inverse characteristic (0.5~32A)[...]

  • Page 10

    10 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Over current and time setting tips ● Over current Setting tips in definite TCC mode 1. Over current threshold (OC) : - Set the OC at the rating [...]

  • Page 11

    11 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Front face 3 phase currents (In) and the leakage current are displayed every 2 seconds in sequence. Bar graph  it shows the load factor to OC s[...]

  • Page 12

    12 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT L1 current display 2sec 2sec 2sec 2sec L2 current display Rotate L3 current display GF current 3 phase digital ammeter function  Blocking displ[...]

  • Page 13

    1 Password 2 Selection of Phase 3 TCC Selection 4 Frequency 5 Fail Safe Reversed Phase 6 detection 7 Over Current Threshold 8 Start Delay Time 9 Over Current Duration Under Current 10 Threshold Under Current 11 Duration Earth Fault 12 (Ground Fault) Threshold 13 Earth Fault Duration 14 EF starting Delay 15 Phase Loss 16 Phase Loss Time 17 Unbalance[...]

  • Page 14

    Threshold of Alert output, set by % of the over current threshold (oc). If the load current is higher than this value, alert output(07-08 contact) is energized according to the setting of “ ALo:XX ” . If the load current is detected, alert output(07-08 contact) is energized. The alert threshold is no meaning for this operation. Refer to the Ale[...]

  • Page 15

    15 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Trip Indication Trip Indication after trip with UP/ DN button pressing Trip Cause Indication Contents of Indication L1 LED on L2 LED on L3 LED on [...]

  • Page 16

    16 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Wiring Examples EOCR-i3BZ/iFBZ OL : b, GR : a EOCR-i3BZ/iFBZ OL : 1a 1b, GR : 1a 3 phase line Diagram 3 phase line Diagram 3 phase line Diagram Si[...]

  • Page 17

    17 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Dimensions EOCR-i3BZ / 3BZ2 (Bottom Hole) EOCR-i3BZ / 3BZ2 (Teminal Type) 70 95 82 ∅ 4.5 6- M 4 21.4 21.4 108.1 45.3 53.3 91.3 3- ∅ 12 108.1 2[...]

  • Page 18

    18 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Order Code i3BZ Intelligent, panel mounting unit  Basic Unit iFBZ Intelligent, flush mounting unit 3BZ2 Economic, panel mounting unit FBZ2 Econ[...]

  • Page 19

    19 Communication setting value Please set the Modbus communication parameters by PCON or HMI for the communication.  Slave address  Baud rate  Parity  Communication loss timeout Slave address The EOCR has slave addresses from 1 to 247. The factory default setting is 1. Baud rate The Communication speed provided is like below.  1.2kbp[...]

  • Page 20

    20 Communication Guide The standard connection conforms to the Modbus specifications, sepecially 2 wire multidrop serial bus diagram, presented at the website of Modbus.org in 2002 (Modbus_over_serial_line_V1.pdf, Nov.2002). Simple wiring diagram is like below. The characteristics is like below in case of a direct connection to the bus. Items Conte[...]

  • Page 21

    21 Communication Guide Bus connection thr ough a SCA type junction box 1. Master (PLC, PC or communication module) 2. Modbus cable (It is different according to the master side or a master having polarization combined to the other part of Bus) 3. Junction box 4. Modbus cable 5. Line terminators : 120 Ω - 0.25W Please use a cable with 2pair shiede[...]

  • Page 22

    Built_in ZCT catalog_EN ⓒ 2009 Samwha EOCR Ltd.-All rights reserved. 04/2009 Head Office 6 th floor, Jeil Bldg., 94-46, Youngdeungpo-Dong 7Ka, Youngdeungpo-Ku, Seoul, Korea Tel. 82 2 3473 2340 / Fax 82 2 3473 1159 Iksan Plant 574, Yongie-dong, Iksan-shi, Junbuk, Korea Tel. 82 63 835 5033 / Fax 82 63 835 4175 www.eocr.com[...]