Go to page of
Similar user manuals
-
Air Conditioner
Soleus Air air-condition
13 pages 0.38 mb -
Air Conditioner
Soleus Air GM-CAC-12SE
23 pages 0.94 mb -
Air Conditioner
Soleus Air KFH-18
26 pages 2.66 mb -
Air Conditioner
Soleus Air SG-TTW-10ESE
15 pages 2.15 mb -
Air Conditioner
Soleus Air SG-Pac-08E4
16 pages 2.03 mb -
Air Conditioner
Soleus Air SOLEUSAIR SG-PAC-10E5
15 pages 1.02 mb -
Air Conditioner
Soleus Air GM-PAC-10E2
18 pages 5.95 mb -
Air Conditioner
Soleus Air KC-25U
14 pages 1.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Soleus Air KFHHP-22-OD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soleus Air KFHHP-22-OD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Soleus Air KFHHP-22-OD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Soleus Air KFHHP-22-OD should contain:
- informations concerning technical data of Soleus Air KFHHP-22-OD
- name of the manufacturer and a year of construction of the Soleus Air KFHHP-22-OD item
- rules of operation, control and maintenance of the Soleus Air KFHHP-22-OD item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soleus Air KFHHP-22-OD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soleus Air KFHHP-22-OD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soleus Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soleus Air KFHHP-22-OD.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Soleus Air KFHHP-22-OD item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-22-ID / KFHHP-22-OD Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference . Indoor Unit . Outdoor Unit .[...]
-
Page 2
TABLE OF CONTENTS OPERATION AND MAINTENANCE…………..………..…………………………………….....1-12 Instructions before Use ……………………………………………………………………………1-2 Description of Air Conditioner Components………………………………………………...………3 Remote[...]
-
Page 3
- 1 - Operation and Maintenance ◆ Instructions before Use Carefully read the following instructions before use Warning ★ Do not use flammable liquids on or near this air conditioner. ★ Touching metal parts after rem oving filter can cause an electric shock. ★ Do not use for long periods of time if the humidity is high. Condensation may be p[...]
-
Page 4
- 2 - ◆ Instructions before Use ★ Don’t attempt to repair the air conditioner by yourself. There are no user replaceable parts. Please contact your authorized dealer. ★ Always use new batteries in your remote. Never mix batteries. ★ Be sure to turn the power off when not using the air conditioner for a long time. ★ Never store flammable[...]
-
Page 5
- 3 - ◆ Description of Air Conditioner Components Air intake Air outlet On/Off Swi tch Connecting Pipe / Line set On/Off Switch Signal Sensor[...]
-
Page 6
- 4 - ◆ Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will au tomatically resume its last running mode, and the outdoor unit will start there after. TEMP+ TEMP- Button:[...]
-
Page 7
- 5 - ◆ Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. ON/OFF Button Press ON. Press OFF. T-ON Button. When pressing this b utton once, enter in to T-ON setting, the icon of T-ON flash, every press of TIME+, the time of T-ON will be increased 1min. When contin uously press 1 sec above, the tens placed on m[...]
-
Page 8
- 6 - ◆ Remote Control Operation (Continued) The General Procedure: 1. Press ON/OFF button to start the unit. 2. Press MODE button to select the suitable operation mode. 3. Press SWING button to swing. It will stop when pressed again. 4. Press FAN button to set desired fan speed. 5. Press +/- button to se t desired temperature. The Selected Proce[...]
-
Page 9
- 7 - ◆ User Notices ★ Select the most comfortable temperature. ★ The airflow direction can be adjusted. At operating, adjust the ve rtical airflow direction by adjusting the louvers of upward/downward direction. And then, hold two ends of left and right louver to adjust the horizontal airflow. ★ Don’t leave windows and doors open for a l[...]
-
Page 10
- 8 - ◆ Care and Maintenance CAUTION: Turn power off and pull out the power cord before cleaning air conditioner. Never sprinkle water on the i ndoor unit and the outdoor unit fo r cleaning because it can cause an electric shock. Volatile Liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, [...]
-
Page 11
- 9 - ◆ Care and Maintenance (Continued) 3. Reinsert the filters Reinsert the filters along the direction of arrow, then cover the surface panel and clasp it. Check before Use 1. Be sure that nothing ob structs the air outlet and intake vents. 2. Verify that the unit is properly grounded. 3. Always use new batteries. 4. Verify condenser is proper[...]
-
Page 12
- 10 - ◆ Trouble Shooting Problem Trouble Shooting Sound of water flow can be heard during operation. This is caused by the refriger ant flowing inside the unit. Mist is emitted during cooling operation. Because the air of the room is cooled down rapidly. Creaking noise can be heard wh en start or stop the unit. This is caused by the ex pa nsion [...]
-
Page 13
- 11 - ◆ Specifications and Technical Data Model KFHHP-22-ID / KFHHP-22-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 22000 / 6450 (2250-7000) Heating capacity(BTU/hr) & (Watts) 24200 / 7100 (1650-8500) Rated voltage 208-230V ~ Rated Frequency 60Hz Cooling/Heating ra ted current(A) 10.0/9.3 Cooling/Heating rated pow[...]
-
Page 14
- 12 - Installation Services ◆ Installation Diagram Important Notes The installation must be done by trained and qualified service personnel.[...]
-
Page 15
- 13 - ◆ Installation Location Indoor Unit 1. The inlet and outlet should not be covered so th at the outflow air can re ach all parts of the room. 2. Install in a location from which the condens ation water can be drained out conveniently. 3. Avoid a location where there is heat source, steam or flammable gas. 4. Install in a location where is s[...]
-
Page 16
- 14 - ◆ Installation Install the rear panel 1. Always mount the rear panel horizontally. Becau se th e mouth of drainage pipe is at the left side and the left side of the rear panel is better to adjust slightly lower. 2. Fix the rear panel on the selected location with screws supplied with the unit. 3. Be sure that the rear panel has been fixed [...]
-
Page 17
- 15 - ◆ Installation Wiring of indoor unit Note: The power of indoor unit is su pplied by the outdoor. A breaker need s to be installed for safety. Operation Procedures: 1. Open the surface panel. 2. Open the cover and cover plate of electric box. (Right figure) 3. Remove the receiving window as shown in the below left figure. 4. Wire pipe shoul[...]
-
Page 18
- 16 - ◆ Installation Electric Wiring Note: Wiring must be done by a certified technician ac cording to the local rules & regulations. T he connecting wire should be correctly connected to ci rcuit interface. Otherwise, it can cause a fire, electricity leakage and so on. The diagram is shown as below: NOTE: 1. Wiring s hould be c orrectly ins[...]
-
Page 19
- 17 - ◆ Installation Wiring of Outdoor unit Operation Procedures: • Open the cover of outdoor unit. • The connecting wire led from the terminal board of indoor unit should be connected correctly. • The connecting wire should be a little longer so that it can easily maintained. NOTE: 1. Wiring s hould be c orrectly instal led. 2. Tighten t [...]
-
Page 20
- 18 - ◆ Installation Install the Power Line 1. Remove the front side plate. 2. Break through the hole for wires and put on the rubber bushing. 3. Pull all wires through the rubber bushing. 4. Remove the wire clamp and connect the end of the power connection co rd with screws to the wiring terminal board according to the “WIRING DIAGRAM” of t[...]
-
Page 21
- 19 - ◆ Installation Install the Outdoor Unit Install the connection pipe: • Align the center of the piping flare with the valve. • Screw in the flare nut by hand and then tighten the nut with spanne r and torque wrench refer to right figure. Note: Exceeding tightening torque will damage the fla re nut. Tightening Torque Table Hex Nut Diamet[...]
-
Page 22
- 20 - ◆ Installation Air Purging and Leakage Test 1. Connect charging hose of manifold value to charging end of low pressure valve (both high/low pressure valves must be tightly shut). 2. Connect joint of charging hose to vacuum pump. 3. Fully open handle of Lo manifold valve. 4. Open the vacuum pump to evacuate. At the beginning, slightly loose[...]
-
Page 23
- 21 - ◆ Test Operation and Check after Installation Test Operation 1. Test Operation (1) Do not switch on power before installation is finished completely. (2) Electric wiring must be connected correctly and s ecurely (3) Cut-off valves of the conn ection pipes should be opened. (4) All the impurities such as scraps m ust be cleared from the uni[...]
-
Page 24
- 22 - Electrical Schematic Diagram ◆ Electrical Schematic Diagram (Indoor Unit) Please Help Insert Diagram in here.[...]
-
Page 25
- 23 - ◆ Electrical Schematic Diagram (Outdoor Unit) Please Help Insert Diagram in here.[...]
-
Page 26
- 24 - Warranty Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFHHP-22-ID/KFHHP-22-OD) to be free of defects in material and workmanship for the applications specified in its operation instruc tion for th e period of parts specified below. 5 YEARS FOR COMPRESSOR 1 YEAR FOR OTHER CO[...]