The rules should oblige the seller to give the purchaser an operating instrucion of Soleus Air KY-320, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soleus Air KY-320 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Soleus Air KY-320. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Soleus Air KY-320 should contain:
- informations concerning technical data of Soleus Air KY-320
- name of the manufacturer and a year of construction of the Soleus Air KY-320 item
- rules of operation, control and maintenance of the Soleus Air KY-320 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soleus Air KY-320 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soleus Air KY-320, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soleus Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soleus Air KY-320.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Soleus Air KY-320 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    [...]

  • Page 2

    T ABLE OF CONTENTS INTRODUCTION 1 IMPORT ANT SAFEGUARDS 1 P ACKAGE CONT AINS: 1 NAMES OF P ARTS 2 INST ALLA TION BEFORE USE 3 CONTROL P ANEL AND LCD DISPLA Y 5 CONTROL PANEL FUNCTIONS 6 OPERA TION USING CONTROL P ANEL 7 OPERA TION USING REMOTE CONTROLLER 8 CONDENSA TE W A TER DRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL SPECIFICA TIONS 1[...]

  • Page 3

    1 INTRODUCTION Thank you for purchasing the Soleus Air KY32U portable air-conditioner . This unit is designed for improving living and working comfort by providing cooling, dehumidifying and fan functions only with a minimum installation required. W ith its whisper quite operation and attractive design, you will enjoy the convenience and comfort th[...]

  • Page 4

    2 NAMES OF P ARTS Front V iew Back V iew control panel upper air outlet handle lower air inlet grille Signal Receptor upper air inlet grill with filter power cord hot air exhaust outlet lower air inlet grille water tank continuous drainage Exhaust Duct T erminal[...]

  • Page 5

    3 Exhaust Duct W indow Kits INST ALLA TION BEFORE USE 1) Condensate W ater T ank Float Lid Y ou must install the water tank float lid before first use of the portable air conditioner following these procedures: a) Hold the water tank and draw it out slowly . b) Remove water tank float lid and packing material from the water tank. c) Insert the floa[...]

  • Page 6

    4 water tank float lid should be able to move up and down freely after correct installment. d) Insert the complete water tank back to the air conditioner unit. 2) Exhaust Duct When you use the unit as an air conditioner , the hot exhaust air must be directed out of the room. The exhaust duct is used to allow the hot air out. DO NOT INST ALL OR USE [...]

  • Page 7

    5 f ) Use screws on the window kit extension if necessary . NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements should be taken. CONTROL P ANEL AND LCD DISPLA Y CONTROL P ANEL LCD DISPLA Y[...]

  • Page 8

    6 Control Panel Functions 1) Power On/Off Control Starts or Stops the Unit 2) Mode Control Select the functions of the unit for: Fan only Air Conditioning onlyDehumidifying only Auto Control 3) Fan Speed Control Select the fan speed for: High Medium Slow 4) T emperature Setting Control Select the desired temperature setting by pressing either / or[...]

  • Page 9

    7 OPERA TION USING CONTROL P ANEL 1) Cooling Operation a) Be sure that the drain tank is properly placed in the unit. b) Install the exhaust duct properly . c) Plug the Power Cord to the power outlet. d) T urn on the unit by pressing the On/Off Button on the control panel. For Manual Mode: Press the Mode Button until the snowflakes and  Cool [...]

  • Page 10

    8 NOTE: Do not use the exhaust duct when the unit is running at dehumidifying model. Y ou must remove the exhaust duct from the unit. When the unit is running at dehumidifying mode, the fan speed cannot be adjusted. Keep the windows and the doors closed to aid the effectiveness of the unit in removing the moisture from the room. 3) Fan Operation a)[...]

  • Page 11

    9 REMOTE CONTROLLER 1) Set Clock a) Press On/Off key to turn on the remote controller b) Press left side (Hour) or right side (Minute) of the T ime Adjustment key until the LCD displays the correct time. c) Press the T ransmit key to set time. 2) Cooling Operation a) Press the On/Off key to turn on the remote controller b) Press the Mode key until [...]

  • Page 12

    10 d) Press the Fan Speed key until the LCD displays the desired fan speed. e) Press the T ransmit key . NOTE: When pressing the Mode Key , the LCD displays “COOL”, “F AN” AND “HEA T”. This KY-32U unit does not have a heating function. 3) Dehumidifying Operation a) Press the On/Off key to turn on the remote controller b) Press Dehumidif[...]

  • Page 13

    11 7) Sleep Mode a) Press the On/Off key to turn on the remote controller . b) Press the Sleep key . “Sleep” will appear on the LCD display . c ) Press either / of / key of the T emperature key until the LCD displays the desired temperature. d) Press the Fan Speed key until the LCD displays the desired fan speed. e) Press T imer and T ime Adj[...]

  • Page 14

    12 mode, condensate water does not go to the internal water tank. Condensate is discharged by gravity through the drainage tubing to either an external tank (not provided) or to a condensate water pump device (Optional Item). When the unit is operating on continuous drainage mode, it can operate con- tinuously without periodic stops to empty the wa[...]

  • Page 15

    13 maintenance activities. 1) Clean or replace filter If the air filter is blocked with a lot of dust, the airflow volume will reduce. It is recommended to clean the filter once every two weeks or as needed. a) Push down the two tabs on the filter cover and pull outwards to remove the entire filter and cover . b) Carefully , take the air filter out[...]

  • Page 16

    14 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE REMEDY Unit does not operate Unit is unplugged Securely plug receptacle into the power outlet Drain tank is full Empty water tank W ater tank not installed correctly Completely insert water tank Air exhaust is clogged Clear exhaust hose T imer is on Cancel the timer and wait for it to run automatically Ther[...]

  • Page 17

    15 TECHNICAL SPECIFICA TIONS NOTE: 1 ) The above cooling capacity is measured at ambient temperature of DB 86 F , WB 78 F . 2 ) Noise level is measured at the point where is 3.28 ft away from the front of the unit, in cooling mode. 3 ) Power consumption is measured when fan runs at the highest speed Specifications above are for reference only . Ple[...]

  • Page 18

    16 ELECTRIC PRINCIPLE DRA WING KY-32U[...]

  • Page 19

    17 W ARRANTY ONE YEAR LIMITED W ARRANTY Soleus International Inc. warrants the accompanying Soleus Air KY-32U Mobile Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada. If t[...]

  • Page 20

    18 LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and[...]