Stanley Black & Decker SM50 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Stanley Black & Decker SM50, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Stanley Black & Decker SM50 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Stanley Black & Decker SM50. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Stanley Black & Decker SM50 should contain:
- informations concerning technical data of Stanley Black & Decker SM50
- name of the manufacturer and a year of construction of the Stanley Black & Decker SM50 item
- rules of operation, control and maintenance of the Stanley Black & Decker SM50 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Stanley Black & Decker SM50 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Stanley Black & Decker SM50, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Stanley Black & Decker service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Stanley Black & Decker SM50.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Stanley Black & Decker SM50 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    © 2014 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 52724 2/2015 V er . 6 USER MANUAL Safety , Operation and Maintenance SM50 HYDRAULIC SUMP PUMP[...]

  • Page 2

    2 ► SM50 User Manual DECLARA TION OF CONFORMITY DECLARATION OF CONF ORM ITY ÜBEREINSTIMM UNGS - ERKLARUNG DECLARATION DE CONF ORMITE CEE DECLARACION DE CONFO RMIDAD DICHIARAZIONE DI CONFO RMITA Hydraulic Tools _______ _________ ___________ ___________ _________ ___________ _________ ___ I, the undersigned: Ich, der Unterzeichnende: Je soussi gn?[...]

  • Page 3

    SM50 User Manual ◄ 3 DECLARA TION OF CONFORMITY .......................................................................................................................... 2 SAFETY SYMBOLS .................................................................................................................................................. 4 SAFETY PREC[...]

  • Page 4

    4 ► SM50 User Manual Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel. Safety symbols and signal words, as shown below , are used to emphas[...]

  • Page 5

    SM50 User Manual ◄ 5 T ool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hose. These safety precautions are given for your safety . Re- view them carefully before operating the tool and before performing general maintenance or repairs. [...]

  • Page 6

    6 ► SM50 User Manual 52728 SM50 Combined Decal C AU TI O N SAFETY T AG P/N 15875 (Shown smaller then actual size) DANGER DANGER READ OPERA TION MANUAL AND SAFETY INSTRUCTIONS FOR THIS TOOL BEFORE USING IT . USE ONL Y P ARTS AND REP AIR PROCEDURES APPROVED BY ST ANLEY AND DESCRIBED IN THE OPERA TION MANUAL. T AG TO BE REMOVED ONL Y BY TOOL OPERA T[...]

  • Page 7

    SM50 User Manual ◄ 7 The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools. They are: Certied non-conductive — constructed of thermoplastic [...]

  • Page 8

    8 ► SM50 User Manual Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose - Fiber Braid - for Utility Bucket T rucks 4-9 15-34 up to 10 up to 3 3/8 10 Both 2250 155 Conductive Hose - Wire Braid or Fiber Braid -DO NOT USE NEAR ELECTRICAL CONDUCT ORS 4-6 1[...]

  • Page 9

    SM50 User Manual ◄ 9 Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max. uid viscosity of: (at min. operating temperature) T emperature: Sufcient heat rejection capacity to limit max. uid tempe[...]

  • Page 10

    10 ► SM50 User Manual PREOPERA TION PROCEDURES CHECK POWER SOURCE 1. Using a calibrated ow meter and pres sure gauge, make sure the hydraulic power source develops a ow of 7–12 gpm/26–45 Ipm at 1000–2000 psi/70– 140 bar . 2. Make certain that the power source is equipped with a relief valve set to open at 2100 psi/145 bar maxi- mum.[...]

  • Page 11

    SM50 User Manual ◄ 1 1 CLEANING THE PUMPING CHAMBER Debris such as weeds, sand and other solids may be- come trapped in the water hose and pumping chamber . This can reduce pump performance. It is important that the pumping chamber be kept clean at all times. The chamber can be cleaned as follows: 1. Remove motor and impeller by removing the two [...]

  • Page 12

    12 ► SM50 User Manual • Make sure all couplers are wiped clean before con- nection. • The hydraulic circuit control valve must be in the “OFF” position when coupling or uncoupling hydrau- lic tools. Failure to do so may result in damage to the quick couples and cause overheating of the hy- draulic system. • Always store the tool in a cl[...]

  • Page 13

    SM50 User Manual ◄ 13 If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem. When diagnosing faults in operation, always make sure the hydraulic power source is supplying the correct hydrau- lic ow and pressure as listed in the table. Use a owmeter know to be accurate. Check the ow wit[...]

  • Page 14

    14 ► SM50 User Manual Capacity......................................................................................................................................... 500 gpm/1890 lpm Weight ..................................................................................................................................................... 21 lbs[...]

  • Page 15

    SM50 User Manual ◄ 15 65132 MOTOR ASSEM- BL Y USED ON SUMP PUMPS WITH SERIAL NUMBERS 600 AND ABOVE, THIS MOTOR CAN ONL Y BE PUR- CHASED AS AN ASSEM- BL Y . INDIVIDUAL P ARTS ARE NOT A V AILABLE. SM50 P ARTS ILLUSTRA TION[...]

  • Page 16

    16 ► SM50 User Manual ITEM NO. P ART NO. QTY DESCRIPTION 1 52669 1 VOLUTE 2 52720 1 CAMLOCK COUPLING 3 IN. 3 13815 1 HSHCS 5/16 – 18 × 3/4 4 56763 1 WASHER 5 00635 1 KEY 6 52671 1 IMPELLER 7 31032 1* SHIM .020 (* NOTE QTY WHEN DISASSEMBLING TOOL) 8 31033 1* SHIM .010 (* NOTE QTY WHEN DISASSEMBLING TOOL) 9 31034 1* SHIM .005 (* NOTE QTY WHEN DI[...]

  • Page 17

    SM50 User Manual ◄ 17 For underwater hydraulic tools the applications are broken down into four quadrants depending on type of tool and method of operation. The types of tools are percussive and rotational, each with different characteristics allowing for dif- ferent depth operation. With percussive tools, the nitrogen accumulator PSI must counte[...]

  • Page 18

    Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulics.com[...]