Go to page of
Similar user manuals
-
Network Card
Star Micronics TCP100 Series
13 pages 0.12 mb -
Network Card
Star Micronics D6-IN
71 pages 0.46 mb -
Network Card
Star Micronics TCP2000 Series
13 pages 0.12 mb -
Network Card
Star Micronics Power Unit PS60A-24A
2 pages 0.11 mb -
Network Card
Star Micronics IS-NP192
20 pages 0.45 mb -
Network card
Star Micronics WIFI Power Pack
2 pages -
Network Card
Star Micronics TCP400 Series
60 pages 1.57 mb -
Network Card
Star Micronics IP-NPC
16 pages 0.35 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Star Micronics IS-NP192, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Star Micronics IS-NP192 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Star Micronics IS-NP192. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Star Micronics IS-NP192 should contain:
- informations concerning technical data of Star Micronics IS-NP192
- name of the manufacturer and a year of construction of the Star Micronics IS-NP192 item
- rules of operation, control and maintenance of the Star Micronics IS-NP192 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Star Micronics IS-NP192 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Star Micronics IS-NP192, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Star Micronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Star Micronics IS-NP192.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Star Micronics IS-NP192 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
USER’S MANUAL Р УК ОВ О ДСТВО ПОЛЬ ЗОВА ТЕЛЯ SERIAL INTERF ACE UNIT МО ДУ ЛЬ ПОС ЛЕД ОВА ТЕ ЛЬНОГ О ИНТЕР ФЕЙСА IS-NP192 PBA10 SIF 80825940[...]
-
Page 2
Notice • All rights reserved. Reproduction of any part of this manual in any form whatsoever , without ST AR’s express permission is forbidden. • The contents of this manual are subject to change without notice. • All ef forts have been made to ensure the accuracy of the contents of this manual at the time of going to press. However , shoul[...]
-
Page 3
English CONTENTS Chapter 1: Serial Interface Unit .............................................................. 2 Unpacking .......................................................................................... 2 Chapter 2: Installation .............................................................................. 2 Installing the serial inter[...]
-
Page 4
2 Serial Interface Unit This serial interface unit makes it possible for your printer to communicate with your computer using serial data. This manual describes the operational procedures for using the serial interface unit. Unpacking • After removing the contents from the packaging, check to make sure you have all seven items. If anything is mis[...]
-
Page 5
3 English Installing the serial interface unit • First remove the printer cover by pushing in the tabs located on both sides of the lower rear of the printer with a screwdriver as illustrated below . • Set the DIP switches on the serial interface unit to the settings that you want. See “Setting the serial interface unit’s DIP switches” on[...]
-
Page 6
4 And secure interface unit in place with the two small screws. Finally , install the printer cover. Connecting a serial cable • Unplug the printer from its AC power outlet. Plug one end of a serial cable into the printer’s serial port and secure it in place with the two screws on the cable. • Plug the other end of the serial cable into one o[...]
-
Page 7
5 English NOTE: The printer is equipped with a serial interface for connecting the op- tional serial interface unit. This makes it possible to connect two separate computers for serial data communication. Setting the printer ’s Electronic DIP switches (EDS) Y ou should set the printer ’ s Electronic DIP switches so they match the set- tings you[...]
-
Page 8
6 Switch 2: Parity Check This switch specifies whether or not a parity check should be performed on the data. Parity Check SW2 DOS Setting Disabled ON Disabled Enabled OFF Enabled Switch 3: Parity This switch specifies the parity as non, odd, or even. Parity SW3 DOS Setting Odd ON O Even OFF E Switch 4: Protocol Protocol, which is sometimes referre[...]
-
Page 9
7 English Baud Rate SW1 SW2 SW3 DOS Setting 300 OFF OFF OFF 300 600 ON OFF OFF 600 1200 OFF ON OFF 1200 2400 ON ON OFF 2400 4800 OFF OFF ON 4800 9600 ON OFF ON 9600 19200 OFF ON ON 19200 9600 ON ON ON 9600 Switches 4, 5, 6: Not used Software Settings This section describes how to set up the software of your computer for print- ing over a serial int[...]
-
Page 10
8 T echnical Specifications (Input) Interface: RS-232C-level Synchronization: Asynchronous Baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200 BPS (selectable) W ord length Start bit:2 1 Data bits: 7 or 8 (selectable) Parity bit: Odd, even, none (selectable) Stop bits: More than one bit Signal polarity Mark: Logical 1 (–3V to –15V) Space: Logica[...]
-
Page 11
Ру сский СОДЕРЖАНИЕ Г лав а 1: М одуль последо в ат ельного интерфейса ................................ 10 Распак овка ........................................................................................... 10 Г лав а 2: Инсталляция ................................[...]
-
Page 12
10 Модуль последовательног о интерфейса Данный мо д у ль по сл едова тельного инт ерфейса позв о лит Вашему принтер у в з аим од ейс твовать с Вашим к омпьютеро м с испо льзование м посл ед овате [...]
-
Page 13
11 Ру сский Инсталляция модуля последовательног о интерфейса • Прежд е вс ег о снимите крышк у принтера; для э т ого нажмите отверткой на ушки, распол ож енные с обеих сторон нижней з адней част[...]
-
Page 14
12 Зате м з акрепите мо д уль интерфейса в э том по л о ж ении с помощью дв у х малых винтов. И нак онец установите на мест о крышку принт ера. Подсоединение последовательного кабеля • Отсое динит[...]
-
Page 15
13 Ру сский ПРИМЕЧАНИЕ: Принтер имеет после дова тельный интерфейс для по дсоединения опционального мо дуля после довательного интерфейса. Это позволяет по дключиться к двум разным к омпьюте?[...]
-
Page 16
14 Переключатель 2: Проверка четности Эт о т переклю чат е ль пок азывает, проводит ся или нет проверка четно сти данных. Проверка четнос ти SW2 Выставка DOS За прещена ON За прещ ена Разрешена OFF Раз?[...]
-
Page 17
15 Ру сский Ск орос ть в бодах SW1 SW2 SW3 Выс тавка D OS 300 OFF OFF OFF 300 600 ON OFF OFF 600 1200 OFF ON OFF 1200 2400 ON ON OFF 2400 4800 OFF OFF ON 4800 9600 ON OFF ON 9600 19200 OFF ON ON 19200 9600 ON ON ON 9600 Переключатели 4, 5, 6: Не используются Выставки программн[...]
-
Page 18
16 Т ехнические у словия (Вх од) Интерфейс: RS-232C-leve l Синхронизация: А синхронная Ск орость в бодах: 300, 600, 1200, 2400, 4800, 9600, 19200 бито в в секунд у (с возмо жностью выб ора) Длина слова 1 С тар тбит: 2 Биты да[...]
-
Page 19
[...]
-
Page 20
ST AR MICRONICS ASIA LTD. Rm 1802-6, 18/F ., T ower 2, Enterprise Square 9 Sheung Y uet Road, Kowloon Bay Hong Kong T el: 852-2796-2727 Fax: 852-2799-9344 KEI • INTERNA TIONAL CORPORA TION Matsuya Bldg. 4F 3-2-12 Nihonbashi Ningyocho, Chuo-ku, T okyo 103, Japan T el: 81-3-3249-1531 Fax: 81-3-3249-1532 T elex: 27324 KEIKO[...]