Go to page of
Similar user manuals
-
Battery Charger
Studer Innotec HPC5048
25 pages 0.63 mb -
Battery Charger
Studer Innotec XTH 3000-12
40 pages 1.65 mb -
Battery Charger
Studer Innotec CFC-01
25 pages 1.01 mb -
Battery Charger
Studer Innotec XPC 2200-48
23 pages 0.49 mb -
Battery Charger
Studer Innotec XPC 1112
22 pages 1.09 mb -
Battery Charger
Studer Innotec C3548 COMPACT
23 pages 1.14 mb -
Battery Charger
Studer Innotec XTH 6000-48
36 pages 0.58 mb -
Battery Charger
Studer Innotec C 1600-12
23 pages 0.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Studer Innotec RCC-02, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Studer Innotec RCC-02 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Studer Innotec RCC-02. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Studer Innotec RCC-02 should contain:
- informations concerning technical data of Studer Innotec RCC-02
- name of the manufacturer and a year of construction of the Studer Innotec RCC-02 item
- rules of operation, control and maintenance of the Studer Innotec RCC-02 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Studer Innotec RCC-02 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Studer Innotec RCC-02, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Studer Innotec service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Studer Innotec RCC-02.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Studer Innotec RCC-02 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Studer Innotec Rue des Casernes 57 CH - 1950 Sion Tel: +41 (0)27 205 60 80 Fax: +41 (0)27 205 60 88 E-mail: info@studer-innotec.com We b : www.studer-innotec.com V 2. 1 User Manual Remote control and programming unit RCC-02 and RCC-03 for the Xtender[...]
-
Page 2
Studer Innotec 2 Reference This document applies to ve rsio ns of firmware V1.2.0 or higher of the remote control. Copyright Copyright © Studer Innote c. All rights reserved[...]
-
Page 3
RCC 3 Table of contents Fore word ............................................................................................................................................................... 7 Conve ntio ns ............................................................................................................................................[...]
-
Page 4
Studer Innotec 4 Stop Inv erter o verv oltage ...................................................................................................... ...................... 2 5 Stop Overt empe ratu re ........................................................................................................... ...................... 25 Stop E xcessiv e[...]
-
Page 5
RCC 5 Outp ut v oltage {128 6} .......................................................................................................... ................. 36 Level of battery und er-voltage at no load {1108} ............................................................................ 37 Acoust ic alarm o f the batt ery under -volt ag e {1196 } ...[...]
-
Page 6
Studer Innotec 6 géné ral us e : Inv erte r, Cha rger with grid ...................................................................................... ............. 46 Use of a lim ite d power sourc e .................................................................................................. ................... 4 6 Use t o increase the pow[...]
-
Page 7
RCC 7 FOREWORD This manual contains information rel ating to th e functioning of the RCC- 02 and RCC-03 remote controls. The use of certain functions sometimes requires in creased knowledge in various fields. This manual cann ot pro vid e th is. In c ase o f d oub t, p l ease contact your re seller or installer. C ONVENTIONS This symbol is used to [...]
-
Page 8
Studer Innotec 8 S TUDER I NNOTEC CONTACT DETAILS Studer Innotec Rue des Casernes 5 7 CH – 1950 Sion Tel. +41 ( 0)27 205 60 80 Fax. +41 ( 0) 27 205 60 88 Customer service: info@studer-innotec.com After-sales service: sales@studer-innotec.com Technical support: support@studer-innotec.com Website: www.s tuder-innotec.com Y OUR RESELLER ’ CONTACT [...]
-
Page 9
RCC 9 WARN INGS AN D CAUTIO N W ARRANTY Studer Innotec issues on this product, which they have manufactured and offered for sale, a two year warranty against any material defect or manu factur ing fault from the date of despatch by an agreed Studer Innotec distributor. Any warranty claim will be refused if it is not se nt back to the point of sale,[...]
-
Page 10
Studer Innotec 10 Upd atin g m ust b e do ne in the f ull awa ren ess o f the c aus e a nd i s alw ay s th e re spo nsib ili ty o f th e customer. Par tial updates may cau se ruptures in th e compatibility or in its st ochastic operat ion.[...]
-
Page 11
RCC 11 INTRODUCTION Congratulations! The purchas e of an RCC remote control offers you unlimited access to the various functions of the device s in the Xtend er series. Nu mero us configurations that can now be accessed allow you to o pti mise the o per atio n of the i nsta lla tion. De spi te al l the se o pti ons, the Xtend er w ork s on a simple[...]
-
Page 12
Studer Innotec 12 CONNECTION The RCC-02 remo te con trol must be fir mly fasten ed using 3 screws on a flat support. The remote c o nt ro l RC C - 03 is m ea n t t o b e i nt eg r at ed . I t m u s t b e m o un t e d b y m ea n s of 4 s c re w s ( n o t s up p l ie d) on a flat place withou t any mechanical constrai n ts to the front p late. Once t[...]
-
Page 13
RCC 13 DIMEN SIONS RCC-02 RCC-03[...]
-
Page 14
Studer Innotec 14 QUICK ST ART GUID E The remote control RCC gives you access to a many settings pos sibil ities. H oweve r, in most case s the setting of two parameters is required fo r the perfect running of your installation. A DJUSTMENT OF THE LANGUAGE To begin, set your remote control RCC for a display of the information in English. The basic [...]
-
Page 15
RCC 15 You can now adapt your installatio n to the source which it is connected to. Max. current of the AC sour ce ( power-sharing) {1107}. In case of using the Xtender on a publ ic grid, it is actually the value of the circuit breaker on the source si d e (fuse or breaker). In a building, this value lies generally between 8 and 16A. In the case of[...]
-
Page 16
Studer Innotec 16 A CTIVATION OF THE FUNCTIO N S MART -B OOST I f y o u r A C - I n s o u r c e i s l i m i t e d i n p o w e r , t h e Xtender can work as a support and add the missing power for your loads. First of all, check that you hav e adapted the Xtender t o your source (see previous chapt er: Ada p tation to t h e sourc e { 110 7} ) The ba[...]
-
Page 17
RCC 17 BASI C DISPLAYS W h e n t h e r e m o t e c o n t r o l i s c o n n e c t e d t o a n X t e n d e r , i t i s p o s s i b l e t o a c c e s s d i f f e r e n t d i s p l a y menus divided into dist inct categories. Real time information displ ays on the operating mode of the installa ti on The history of events occu rring in the installation[...]
-
Page 18
Studer Innotec 18 ACTIVATING AND DEACTIVA TING THE COMBI XTENDER W h e n o n e o f t h e d i s p l a y s i s v i s i b l e , i t i s p o s s i b l e t o a c t i v a t e o r d e a c t i v a t e t h e X t e n d e r . T o d o t h i s , simply press the key ES C. The key request on the screen indicates w hether you are going to activate or deactivate t[...]
-
Page 19
RCC 19 ADJUSTMENT OF THE RCC REMOTE C ONTROL This screen gives you access to the remote control basic settings. From one of the basic menu i tems, use the keys UP a nd D OW N until r ea chi ng th e item “Ad jus tme nt o f th e remote control”, then co nfirm using the key SET. When the item to be modified appears on the screen, press t he key SE[...]
-
Page 20
Studer Innotec 20 Duration of the back-lighting {5009} This configuration allows you t o determine after ho w muc h tim e of ina cti vity th e bac k-l igh ting wi ll switch off. Red back-lighting if the Xtender is OFF and if there is a fault {5026} If the Xtender is stopped by a fault (battery underv o ltage, overload, etc.) t he back-lighting flas[...]
-
Page 21
RCC 21 programs. The file is writt en in a directory called STATS and in a subdirectory which indicates the date of backup . Backup of remote control configurations {5015} This function writes useful configurat ions for the operation of the remote control on to the SD card. Y o u c a n u s e t h i s f u n c t i o n t o d o a b a c k u p o f t h e r[...]
-
Page 22
Studer Innotec 22 INFORM ATION O N TH E OPERAT IN G MOD E OF T H E INSTALL AT ION There are two different v iews for displa ying information on the syst em : A simplified and a configurable display. When one of these two displays is visible, it is possible to acti vate or dea cti vate th e sy st em. For fur the r information, please re fer to the p[...]
-
Page 23
RCC 23 The following information is avail able: With regard to the grid input • AC In input voltage • AC In input current • AC In input power • Input frequency • Energy from AC-In of the previous day • Energy from AC-In of the current day With regard to the grid output • Output voltage • Output current • Output power • Output fr[...]
-
Page 24
Studer Innotec 24 EVENT HISTORY This screen allows you to vi ew th e vari ous even ts tha t have occurred in t he installat ion. The events that occur in your inst allation are di splayed on the remote control screen. The events are classified within two categories: • The events tha t may have seri ous consequenc es are display ed up to the mo me[...]
-
Page 25
RCC 25 E RROR I NCORRECT INPUT FREQUENCY The voltage at AC IN d oes not have a frequency includ ed in the admi ssible range for th e Xtender. Solution: When opera ting on a generator, check i ts speed. If you are n ot equiped to measure the gen erator fr equency, meas ure its voltage with no load. Indee d, if the voltage is correct , the frequency [...]
-
Page 26
Studer Innotec 26 The voltage ripple on the batteries may be caused by thei r ageing. In this case, lower the charge current. M ESSAGE P OWER SHARING EXCE E DED ; TRANSFER PROHIBITED The power output of the consumers exceeds the one specified for the source, and the t ransfer relay can not be a c tivated . The Xten der ope rates in inv erte r mode.[...]
-
Page 27
RCC 27 ADJUSTMENT OF THE COMBI XTENDE R G ENERAL The Xtender inverter/c harger has been designed to ensure that all basic fun ctions of an energy management system work completely independe ntly. In its original version, no adju stment is usua lly required. Neverthel ess, in certain inst allation condit ions, it may be ne cessary to adjust some ope[...]
-
Page 28
Studer Innotec 28 According to the user level selected, it is possible t o access several hundred config urations. For this reason, each configuration has a unique ID displ ayed top right. I n the e ve nt o f qu esti ons on the sub jec t of a co nfi gur ati on, ensure that you have this number at hand. When you modify a configurat ion, a star is di[...]
-
Page 29
RCC 29 Not e, that if the s mart b oos t f unc tio n is acti vated, it is po ssible to d is cha rge th e battery even if the inve rter function is locked. Authorised charger {1125} The battery charger f unction is ei ther activated or not. If this function is not authorised, it is necessary to charge the ba tteries using a source of energy not conn[...]
-
Page 30
Studer Innotec 30 Number of critical battery under-vol tages before final stop {1305} and Leadtime to counting the critical battery under -voltages allowed before final stop {1405} The critical battery under- voltages can also be automatically acknowledged in case of undervoltage disap pearance. Like for the und er-voltages (see pr evious paragraph[...]
-
Page 31
RCC 31 The bulk charge and f loating phases canno t be deactivated. If the conditions for starting a new battery charge cycle have co me together, th e bulk charge phase starts immediately. The battery cycle fi ts a large number of batteries by default, irrespectiv e of whether they are gel batteries or not.[...]
-
Page 32
Studer Innotec 32[...]
-
Page 33
RCC 33 Charge current {1138} Use this value in order t o adapt the charge current to the battery . With this configura tion, the maximum current to be used for ch arging y our battery is ad justed. The curren t appropriate for the battery can be fou nd in its technical da ta. The valu e set by this configuration is used during the whole bulk charge[...]
-
Page 34
Studer Innotec 34 Absorption phase {1451} During this phase, the battery accumu lates the fi nal percentages of the energy it is s toring. This phase is carried out with a constant volt age. Authorised absorption {1155} This configuration determines whet her or not th e absorpti on phase is used. If this phase is deactivated , the charger goes dire[...]
-
Page 35
RCC 35 Equalization before absorption phase {1291} This configuration determines in the cha rge c ycle, in which equa liza tion will b e ac tivated, if the equalization is carried out after or before the absorption phase. The equalization phas e is carried out b ef o re the a bs o rp tio n ph ase by def aul t. A. Equalization B. Absorption C. Float[...]
-
Page 36
Studer Innotec 36 End of equalization activated by the current {1168} The equalization phase can be interrupted if th e charge current of t he battery goe s under a cert ain thresh old. This can be use d to limit th e operating period of a genset while keeping an acceptable battery charge. During the equaliza tion phase, the char ge current decreas[...]
-
Page 37
RCC 37 Level of battery under-voltage at no load {1108} Allows adj ustment of the batt ery’s low voltage level at which the inverter and smart boo st f unc tions ar e d eac tiv ate d. Thi s adjustment is ap plied in the case of a zero charge and is automatically adapted wi th regard to the power required f rom the batteries. This configuration is[...]
-
Page 38
Studer Innotec 38 Delay before passing to inverter {1198} When the in put voltage is below th e transfer v oltage to th e inverter, the transfer relay d oes not open immediately . Wi th this configuration, the period during whic h the transfer r emains drawn ca n be specified. After this durat ion, the transfer relay is opened and the inv erter fun[...]
-
Page 39
RCC 39 The auxiliary con tacts respond to vario us signal ty pes presen t ed graphica lly below. The f ol lowi ng typ es o f b asi c ev en ts ma y ac tiv ate the con ta cts: • Simple event • Scheduled event • Level In the followi ng descripti on, each pa rameter ha s two refere nce numb ers. The ref erence on the left relates to au xiliary co[...]
-
Page 40
Studer Innotec 40 Limit the time of activation {1512} {1513} Maximum duration of ac tivation {1 514 } {1515} When the conditions ar e met, ei ther one or two relays are ac tivated perman ently. If you wish tha t the a cti vat io n dur ati on i s lim ited in ti me, even if the conditions are met , you can activate this func tion. O nce th e re lay i[...]
-
Page 41
RCC 41 Inverter or smart boost overload {1228} {1336} Activates the contact in the event of an error due to exc essive power in the inverter or the Smart Boost function. In the event tha t the inver ter disconnec ts due to excess power and it is atte mpting to r e sta rt, the con tac t is n ot a cti va t ed u nti l th e en d of the a tt e mp ts. Ov[...]
-
Page 42
Studer Innotec 42 The auxiliary contact will only be activated afte r the batte ry exceeds agai n a certain voltage value and also after a duration, both indepe nd ently o f the ac tiv ati on p ara me ters . This voltage and this duration are programmable too. • Dynamic compensation of th e thresholds { 1288} {1354} • Voltage 1 a ctive { 1246} [...]
-
Page 43
RCC 43 o Time of end of activa tion {1273} {1382} • Program 2 {1274} {1383} o Days of the week { 1275} { 1384} o Time of start of acti va tion {1276} {1385} o Time of end of activa tion {1277} {1386} • Program 3 {1278} {1387} o Days of the week { 1279} { 1388} o Time of start of acti va tion {1280} {1389} o Time of end of activa tion {1281} {13[...]
-
Page 44
Studer Innotec 44 INFORM ATION O N THE S YSTE M The system inf o rmation allows y o u to check th e versions of the various elemen ts of your instal la tion. R EMOTE CONTROLS You will receive information on the hardware and software versions for each remote control. Furthermore, you have a ccess to its unique ID n umber. This uni que num ber is mar[...]
-
Page 45
RCC 45 UPDATE S The RCC remo te control program as well as the code in the i nverters/ch argers of the X tender series can be updated in order t o integrate new features. For the RCC remote control it is also possibl e to implement new display languages (up to a maximum of 4 on each RCC remo te control). You ma y obt ain information about the avail[...]
-
Page 46
Studer Innotec 46 APPLICATION EXAMPLES The examples b elow illustrate some imp lementation op tions for current install ations. Useful configurations for these situations are also given. These are common a nd non-obligatory configurations. For more details on each configuration shown, please refer to the complete description given above in this man[...]
-
Page 47
RCC 47 U SE TO INCREASE THE POWER ON AN EXISTING INSTALLATION Description: The availability of an inv ert e r or a inverter/charge r allows its power to be extended with an Xtender connected in cascade. The m aximum power of the firs t inverter is li mited by the maximu m curren t from the transfer relay of the Xtender. Associated current configura[...]
-
Page 48
Studer Innotec 48 ANNEXES A NNEXE 1 : L IST OF CONFIGURATION INTERDEPE NDENCIES N° Configuration N° Minimum li mit by N° Maximum limit by 1108 Underv oltage of the empty batt ery 1109 Under volt age of the charged battery 111 0 Rea cti vatio n volt ag e after battery undervol tage 1109 Underv oltage of the charged battery 1108 Under volt age of [...]
-
Page 49
RCC 49 1308 Temperatu re at which the charge current begins to reduce 1115 Maximum operating temperatur e 1140 Battery maintenance voltage (floating) 1156 Battery absorption voltage 1152 Startup voltage of the timer before alarm 1156 Battery absorption voltage 1156 Battery absorption voltage 1140 Battery maintenance voltage (floating) 1164 Battery [...]
-