Go to page of
Similar user manuals
-
Switch
Symbol Technologies 5000
20 pages 2.71 mb -
Brush Cutter
Symbol Technologies T350
24 pages 2.64 mb -
Network Router
Symbol Technologies AP-4131
250 pages 3.62 mb -
Brush Cutter
Symbol Technologies B450
24 pages 2.64 mb -
Scanner
Symbol Technologies DS 3408
2 pages 1.61 mb -
Network Card
Symbol Technologies LA-5030
106 pages 0.6 mb -
PDAs & Smartphones
Symbol Technologies S P T 1 7 0 0
30 pages 0.58 mb -
Switch
Symbol Technologies WS 2000
150 pages 3.63 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Symbol Technologies PL460, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Symbol Technologies PL460 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Symbol Technologies PL460. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Symbol Technologies PL460 should contain:
- informations concerning technical data of Symbol Technologies PL460
- name of the manufacturer and a year of construction of the Symbol Technologies PL460 item
- rules of operation, control and maintenance of the Symbol Technologies PL460 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Symbol Technologies PL460 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Symbol Technologies PL460, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Symbol Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Symbol Technologies PL460.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Symbol Technologies PL460 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PL360/460 Cradle Quick Reference Guide[...]
-
Page 2
2 PL360/460 Cradle © 2001 - 2006 SYMBOL TECHNOLOGIES, INC. All rig hts reserved. Symbol reserves the right to make cha nges to any product to improve reliability , function, or design. Symbol does not assume any product liability arising out of, or in conne ction with, the application or use of any product, ci rcuit, or application described h ere[...]
-
Page 3
Quick Reference Guide 3 Introduction The PhaserLink 360/460 cradle acts as a stand, host communication interface, and charger for the Phaser scanner. For convenience, the cradle can sit on a desktop or be mounted on a wall. The cradle receives data from the scanner via connectors in the bottom of the scanner and the top of the cradle. It then trans[...]
-
Page 4
4 PL360/460 Cradle Parts Scanner Suppo rt T ab Charging/C ommu ni cation Contacts Charging LED Indicator COM 1 COM 2 Power Port W all-moun ting Socket 1 Wall-mounting Socket 2[...]
-
Page 5
Quick Reference Guide 5 Connecting to the Host There are three ports on the bottom of the cradle. COM 1 connects to the host computer; CO M 2 is used for daisy-chaining multiple cradles together; and, the Power Port supplies powe r to the cradle. Daisy-Chaining T o daisy-chain two or more cradles together , connect COM 1 of th e first cradle to the[...]
-
Page 6
6 PL360/460 Cradle Wall Mounting Before wall-mounting the cradle, the scann er support tab must be changed from the desk-mount position to the wall-mount position. Desk Mount W all Mount 1. Lift the scanner support tab out of the top part of the cradle and replace it in the wall-mount position as shown. 2. Seat the cables from the bottom of the cra[...]
-
Page 7
Quick Reference Guide 7 Inserting Phaser in the Cradle Place the Phaser scanner in the cradle so th at the top of the scanner sits in the larger part of the cradle and the metal contacts on the bottom of the scanner touch the contacts on the cradle. Sending Data to the Host Computer T o set up the PhaserLink cradle fo r communication between a Phas[...]
-
Page 8
8 PL360/460 Cradle T roubleshooting If the cradle does not work after following the operating instructions in this guide: • check the system power . • check for loose cable connections. • ensure the scanner is sitting properly in the cradle. Cleaning Wipe the cradle periodically with a lens tissue or other mater ial suitable for cleaning opti[...]
-
Page 9
Quick Reference Guide 9 - Reduce or eliminate vibration. - Reduce or elimin ate direct pressu re. - Provide adjustable workst ations. - Provide adequate clearance. - Provide a suitable working en vir onment. - Improve work procedures. V ehicle or Forklift Installation Position your device withi n easy reach. Be ab le to access your devic e without [...]
-
Page 10
10 PL360/460 Cradle In accordance with Clause 5, IEC 825 and EN6082 5, the fo llowing information is provided to the user: ENGLISH HEB REW CLASS 1 CLASS 1 LASER PRODUCT CLASS 2 LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT DANISH / DANSK IT ALIAN / ITALIANO KLASSE 1 KLASSE 1 LASERPRODUKT CLASSE 1 PRODOTTO AL LASER DI CLASSE 1 KLASSE 2 LA[...]
-
Page 11
Quick Reference Guide 11 indicate t he recycling mark s on the batt e ries used in sa les, giveawa y or promotion . Contact a qualif ie d T aiwanese recycler for proper batt ery disposal . Symbol Rechargeable Batteries Symbol rechargeable battery p acks are designed and constru c ted to the highest sta ndards within the industry . However , there a[...]
-
Page 12
12 PL360/460 Cradle Marking and Eur opean Economic Area (EEA) Statement of Compliance Symbol T echnologies, Inc., hereby , declares th at this device is in compliance with the essentia l requir ements and other rel evant pro vis ions of Directive 1999/5/EC. A Declaration of Conformity may be o btained f rom http://www2.sym bol.com/doc/ . Waste Elec[...]
-
Page 13
Quick Reference Guide 13 Magyar: Az EU-ban vásá rlóknak: Minden tönkreme nt terméket a Symbol vállalathoz kell eljuttatni újrahasznosítás céljából. A termék visszajuttatás ának módjával kapcsolatos tudnivalókért látogasson el a ht tp://www .symbol.com/environmental_ compliance weboldalra. Nederlands: V o or klanten in de EU: all[...]
-
Page 14
14 PL360/460 Cradle Wall Mounting T emplate Center Line of Cradle Wal l Mounting Socket 2 Wa l l Mounting Socket 1 1 5/16” 11 / 1 6 ” Use 1/8” drill bit for the screw holes. 3 1/2”[...]
-
Page 15
Quick Reference Guide 15 This page is intentionally blank.[...]
-
Page 16
Before you use the unit, it must be confi gured to operate in your f acility’s network and run your applications. If you have a problem running your unit or using your equ ipment, contact your facility’s T echnical or Sy stems Support. If there is a problem with the equipment, they will contact the Symbol Support Center: For the latest vers io [...]