The rules should oblige the seller to give the purchaser an operating instrucion of Teledyne 633, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Teledyne 633 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Teledyne 633. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Teledyne 633 should contain:
- informations concerning technical data of Teledyne 633
- name of the manufacturer and a year of construction of the Teledyne 633 item
- rules of operation, control and maintenance of the Teledyne 633 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Teledyne 633 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Teledyne 633, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Teledyne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Teledyne 633.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Teledyne 633 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

      Model 633 Aethalometer ® Black Carbon Monitor User Manual       © TELEDYNE ADVANCED POLL UTION INSTRUMENTATION 9480 CARROLL PARK DRIVE SAN DIEGO, CA 92121-5201 USA Toll-free Phone: 800-324-5190 Phone: 858-657-9800 Fax: 858-657-9816 Email: api-sales@teledyne.com Website: http:// www .teledy ne-api.com/ Copyright 2012-2013[...]

  • Page 2

    [...]

  • Page 3

    07645A DCN6170 i NOTICE OF COPYRIGHT © 2013 Teledyne Advanced Pollution Inst rumentation, user m anual expanded and edited with permission from Aero sol d.o.o./Magee Scientific. All rights reserved. TRADEMARKS The Aethalometer ® is a registered trademark of Magee Scientific an d the instrument is manufactured by Ae rosol d.o.o. in Slovenia. All o[...]

  • Page 4

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation ii 07645A DCN6170 Thispageintentionallyleftblank.  [...]

  • Page 5

    07645A DCN6170 iii TABLE  OF  CONTENTS   1 INTRODUCTION 5 1.1 Description 5 1.1.1 ‘DualSpot™’ Technology 6 1.1.2 Automatic Zero and Span 10 1.1.3 User and Communications Interfaces 11 1.1.4 Modular Construction 12 1.2 Technical Specifications 13 1.3 Functional Description 14 2 SAFETY NOTES and LABELS 21 3. INSTRUMENT INSTALLATION [...]

  • Page 6

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation iv 07645A DCN6170 5.4 Manual flow meter calibration 55 5.5 Manual stability test 61 5.5 Manual clean air test 61 5.6 Cleaning the optical head 62 5.7 Changing the bypass cartridge filter 65 5.8 Calibrating the tape sensor 68 6 TECHNICAL SUPPORT [...]

  • Page 7

    07645A DCN6170 5 1 INTRODUCTION 1.1  Description    Figure  1.  The  Aethalometer®  Model  633.   The Model 633 represents the “Next Generation” versio n of the r eal‐time Aethalometer rack‐ mount instrument to measure Black Carbon (BC) particles i[...]

  • Page 8

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 6 07645A DCN6170 The Model 633 Aethalometer has been developed with input from t he research and monitoring communities, and is d esigned for reliable operation under all condi[...]

  • Page 9

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 7  The ‘spot loading effect’ is a v ariable phenomenon which appear s a s a g r a d u a l r e d u c t i o n o f  instrumental response as the aerosol deposit de[...]

  • Page 10

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 8 07645A DCN6170   Figure  2.  Aethalometer  da ta  sorted  and  averaged  according  to  loading  (attenuation,  ATN)  on  spot  –  roadside  location  in  London,  UK  (top); [...]

  • Page 11

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 9  It is clearthat the effect,when present, is linearwith loadi ng (‘ATN’).  This canbe represented as:  BC(reported)=BC(zeroloa ding)*?[...]

  • Page 12

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 10 07645A DCN6170 2000 3000 4000 0 20000 40000 60000 80000 BC concent rat i on ( ng/ m 3 ) time (sec) IR, 1 second raw BC1 raw BC2 compensated BC  Figure  3.  The  time  ser ies  of  633  raw  and  compensated  B[...]

  • Page 13

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 11 -500 0 500 1000 1500 2000 2500 14:30:00 14: 35:00 14:40:00 14:45: 00 14:50:00 14:55: 00 15:00:00 15:05: 00 15:10:00 1 secon d tim e-base 30 per . M ov . A vg. (1 secon d tim e- base) 131 ng/ m 3 119 ng/ m 3 Po in t-to-p o in t [...]

  • Page 14

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 12 07645A DCN6170 1.1.4 Modular Construction The Model 633 Aethalometer is constructed with a modular design , so that sub‐units may be e a s i l y s e r v i c e d . T h e o n l y i t[...]

  • Page 15

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 13 1.2  Technical  Specifications   Operation:   Supplyvoltage:100‐240V~,50/60Hz  Maxpowerconsumption:90W  Measurementwavelengths:370,470,525,590,660,880[...]

  • Page 16

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 14 07645A DCN6170 1.3  Functional  Description  The Model 633 features modular design and is composed of severa l s u b s y s t e m s w h i c h a r e s o  interconnected that m ost s[...]

  • Page 17

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 15  ENCLOSURE  The Model 633 enclosure is v ery robust and made from sheet meta l . T h e e n c l o s u r e  mechanically protects the delicate i nner measurement p[...]

  • Page 18

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 16 07645A DCN6170  ETHERNET  CONNECTOR  The Ethernet connector allows the  connection of the Model 633 m easurement system to Ethernetbasedcommunicationnetworks.   COM1,  COM2, ?[...]

  • Page 19

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 17 FLOWMETERS  Two flow meters measure the airflow in different points in the system. One of them is used alsointheairflowregulationloop.  SOLENOID  [...]

  • Page 20

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 18 07645A DCN6170  LIGHT  SOURCE  The light source integrates groups of LEDs of different light w avelengths. It i s one of the main partsofthesystem.  DETECTOR  The?[...]

  • Page 21

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 19 ON/OFF  SWITCH  The secondary ON/OFF switch is located behind the front door. I t is electrically connected in series withthe primary ON/OFFswitch, which i[...]

  • Page 22

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 20 07645A DCN6170 Thispageintentionallyleftblank.[...]

  • Page 23

    07645A DCN6170 21 2 SAFETY NOTES and LABELS CAUTION!  READ  THIS  CHAPTER  VERY  CAREFULLY  BEFORE  OPERATING  THE  INSTRUMENT.   Instrument  operation  R e a d t h i s U s e r ’ s m a n u a l B E F O R E o p e r a t i n g t h e i n s t r u m e n t . I N C O R R ECT instrument?[...]

  • Page 24

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 22 07645A DCN6170 Fire  and  explosion  NEVER install the instrument in explosion‐risk areas and never use the equipmentnearflammablesubstances.    Instrument  overheating ?[...]

  • Page 25

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 23 Instrument  service  and  repair  U N A U T H O R I S E D i n s t r u m e n t s e r v i c e a n d r e p a i r p r o c e d u r e s a r e N O T A LLOWED. T h e i n s t r u m e n t c[...]

  • Page 26

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 24 07645A DCN6170 Moving  parts  During AUTOMATIC tape advance procedure, the measurement chambe r is lifted b y a m o t o r i z e d c h a m b e r l i f t  m e c h a n i s m . T o p r e[...]

  • Page 27

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 25 3. INSTRUMENT INSTALLATION 3.1  Unpacking  the  system  Taketheinstrumentoutoftheb oxandplaceitonanevensurf ace.Keepthebackofthe instrumentaccessible[...]

  • Page 28

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 26 07645A DCN6170 e x h a u s t f r o m t h e H V A C u n i t – t h i s c a n l e a d t o c o n d e n s a t i o n i n s i d e t h e s a m p l e l i n e t u b i n g a n d  candamagethe[...]

  • Page 29

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 27 in v er ted so ra i nc a n no t en ter . A fu nne l o nt h e sa m pl ing e nd of t he in ver te d sa mp lel in e tu b in g withtheopeni ngcoveredbyam esh?[...]

  • Page 30

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 28 07645A DCN6170 indicatedbygreencheckboxesforeachstep.Theins trumentwi llautomaticallybegin measurementsasquicklyasiniti alizationisco mplete,ifthet ouchscreendisplayre[...]

  • Page 31

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 29 3.4  Filter  tape  installation  Inthe“Operation/General”menu (Section4providesinformati onabouttheuserinterface) press“Stop”tostopmeasurement s.(If?[...]

  • Page 32

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 30 07645A DCN6170 Thefirst“TapeChange Procedure”screenis displayedwhilethe chamberlifts,thenthe second“Tapechange Procedure”screenis displayedwithapromptto change[...]

  • Page 33

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 31 Slidetapefrombeneath theopticalchamberand removetheusedtape. Keeptheemptyrollfor usewithnew,replacement tape.  Usingtransparenttape, attachend?[...]

  • Page 34

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 32 07645A DCN6170        Tapedirectionisfrom bottom,lefttoright.   [...]

  • Page 35

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 33 Insertthenewtaperollon theleftsideofthe chamberandrunthetape undertheleftguide‐arm.        Slidethetapeunderthe opticalhead,?[...]

  • Page 36

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 34 07645A DCN6170 Ensurethetapeistaut betweenthetwosides.  Replacethetransparent taperetentiondisks.   Closethedoorandpress OKonthedisplayscreen. [...]

  • Page 37

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 35 Thenext“TapeChange Procedure”screen promptsyoutowaitfor thechambertoreturnto homeposition.  Thenextscreenprovides noticewhenthetape changep[...]

  • Page 38

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 36 07645A DCN6170 3.4  Manually  lifting/lowering  chamber  optical  head  Incasetheinstrumentisturned off,thechambercanbelifted manually,asfollows: (Stopmeasurementsfirst: [...]

  • Page 39

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 37  4 USER INTERFACE, SETTINGS and OPERATION 4.1  User  interface  and  settings  Therearefour1 st levelmenutabsinthetouch‐sc reenuserinterface: HOME,OPER ATION, DATA,?[...]

  • Page 40

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 38 07645A DCN6170 should  you  want  the  flow  to  be  reported  at  0  C,  or  25  C  for  example.  Optionally,  you  can  chose  volumet ric  flow  at  ambient  conditio[...]

  • Page 41

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 39 4.2  Instrument  Status  Theinstrument’scurrentstatus c onditionisdisplayedi ndecim alformatonthefrontpanel HOMEscreenandintheStatusco lumnofthe[...]

  • Page 42

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 40 07645A DCN6170 Single Status Condition IfthevaluedisplayedmatchesavalueintheStatusCondition column,itindicatesonlyone parameteranditsdescription. Examples: ‐ Status [...]

  • Page 43

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 41 Gotothe“Data/Export”menuand press“ExporttoUSB”.The datawillbestoredinatextfile withaheader.The filenameis:   AE33_S ss ‐ [...]

  • Page 44

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 42 07645A DCN6170 Data field description:  Date (yyyy/MM/dd) :date.  Time (hh:mm:ss) :time. ‐ Timebase :timebase–unitsinseco nds.  Ref1,  Sen1Ch1,  Sen2Ch1 …: aretheraw?[...]

  • Page 45

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 43  K1;  K2;  K3;  K4;  K5;  K6;  K7 :K_iare thecompensationpar ametersfor wavelengthsi=1…7  TapeAdvCount :TapeAdvCount–tapeadvancessinces tart ‐?[...]

  • Page 46

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 44 07645A DCN6170 Establishcommunicationsusingthefollowingvalues:  .BaudRate=115200 .DataBits=8 .StopBits=IO.Ports.StopBits.One?[...]

  • Page 47

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 45 Example2:IfyouareusingHyper Terminaljustwritefollowing command$AE33:D1and pressenter(thisshouldaddCRc haracteratendofcommand).  Example3:$AE33:[...]

  • Page 48

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 46 07645A DCN6170 Thispageintentionallyleftblank.  [...]

  • Page 49

    07645A DCN6170 47 5 MAINTENANCE and SERVICE TheAethalometerneedstobemaintainedregularly.Werecommend thefollowingschedule forregularmaintainance.  Item  Frequency  Sampleinletflow Monthly Inspectthesamplelinetubing Monthly Inspectandcleanthesizeselec t[...]

  • Page 50

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 48 07645A DCN6170 5.1  Cleaning  the  cyclone  Removethecycloneanddisassemb le(showninthefollowinginstructions),cleaning the variouspartsthoroughly.There commendedcleaningmethod?[...]

  • Page 51

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 49 3.Loosenthethreesetscre wsthatholdtheinlet bodyinplace. 4.Removeinletbody. 5.Removedustcup. 6.Illustrationshowsinletcover,inletbodyand dust?[...]

  • Page 52

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 50 07645A DCN6170 7.Removeallencapscrewsfromcyclonetop. 8.Cleanallpartsandthoroughlydry;then reassembleinre verseorder.   5.2  Leak  test  Alwaysconductaleakt[...]

  • Page 53

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 51 3. Disconnectflowmeterfromtheinp ut. 4. Connecttheflowmetertotheoutputoftheinstrumentbyalon gtube(10m)toreduce theoscillations,whichcaninfluence?[...]

  • Page 54

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 52 07645A DCN6170 Automatic  flow  calibration  procedure:  1.Stopmeasurementsinthe OPERATION>GENERALmenu(press Stopbutton).  2.IntheOPERATION>ADVANCEDmenu pressFLOWCAL. [...]

  • Page 55

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 53 Automatic  flow  calibration  procedure:  4.Waitforthemeasurementchamberto movetotheupposition.  5.Oncechamberislifted,removetapeand inserttheflow[...]

  • Page 56

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 54 07645A DCN6170 Automatic  flow  calibration  procedure:  7.Connecttheflowme tertotheinletof theAethalometer,no tetheorientation! Connectthedatacab letotheserial connec[...]

  • Page 57

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 55 5.4  Manual  flow  meter  calibration  First,ensurethataleaktestiscompleted(Section5.1)prior torunningthiscalibration procedure.Forthemanualcalibrationa[...]

  • Page 58

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 56 07645A DCN6170 Manual  flow  calibration  procedure:  4. Waitforthemeasurement chambertomovetotheup position.  5. Removetapeandinsertthe flowcalibrationpad(note [...]

  • Page 59

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 57 Manual  flow  calibration  procedure:   7. Waitforthepumptorun forseveralsecondsto achieveastableflow. [...]

  • Page 60

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 58 07645A DCN6170 Manual  flow  calibration  procedure:  8. Inthedisplay’sblank FLOWfieldentertheflow valuefromyourflowmeter measuredinorconverted tomilliliters(thiswil[...]

  • Page 61

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 59 Manual  flow  calibration  procedure:  10. Inthedisplay’sblank FLOWfieldentertheflow valuefromyourflow‐meter measuredinorconverted tomilliliters(thiswi[...]

  • Page 62

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 60 07645A DCN6170 Manual  flow  calibration  procedure:  13. Thescreendisplaysa message,“Waitfor calibrationtofinish”,and thendisplaysnoticewhen thecalibrationisfinish ed a[...]

  • Page 63

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 61 5.5  Manual  stability  test  Stabilitytestisconductedwith outflowtodeterminetheperfo rmanceofthelight source– detectorpair.IntheOp eration/Generaltab[...]

  • Page 64

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 62 07645A DCN6170 5.6  Cleaning  the  optical  head  Optical  head  cleaning  procedure:  1. STOPmeasurementsinthe OPERATION>GENERALmenu.  2. Manuallyliftthechamber (pressingdo[...]

  • Page 65

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 63 Optical  head  cleaning  procedure:  4. Whilepressingtherelease buttonupward,graspoptical headandturntoloosenand remove. 5. Usecompressedair(AVOID spraying[...]

  • Page 66

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 64 07645A DCN6170 Optical  head  cleaning  procedure:  6. Alternatively,useacottonswab. Ensuretocleanbothtopand bottomofopticalhead. Optical head bottom . 7. Returntheopticalhead:[...]

  • Page 67

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 65 Optical  head  cleaning  procedure:   5.7  Changing  the  bypass  cartridge  filter  Bypassfilterchangingprocedure: 1.Openinstrumentdoortoaccess bypasscartridge?[...]

  • Page 68

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 66 07645A DCN6170 Bypassfilterchangingprocedure: 3.Repeatonotherside.  4.Removecartridge.  5.Gentlywedgesmall,flattool betweenfittingandcartridge.  6.Carefullypry?[...]

  • Page 69

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 67 Bypassfilterchangingprocedure: 8.Securelyslidefittingsontoendsof newcartridge.  9.Placenewcartridgeonchamber opticalhead,ensuringthatthe arrowprinted[...]

  • Page 70

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 68 07645A DCN6170  5.8  Calibrating  the  tape  sensor  Tapesensorcalibrationisperform edatthefactoryandshould onlybeconductedwhen removingtheMeasurementchamber from/toth[...]

  • Page 71

    Teledyne Advanced Polluti on Instru mentation Model 633 Aethalometer ® Black Carbon Monitor User Manual 07645A DCN6170 69  Tapesensorcalibrationprocedure: 3.TheTapeSensors Adjustmentscreen promptstoplacethe smalltapeholder [cylinder]onleftand largeonright,then pressOK.?[...]

  • Page 72

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 70 07645A DCN6170 Thispageintentionallyleftblank.[...]

  • Page 73

    07645A DCN6170 71 6 TECHNICAL SUPPORT a nd CONTACT INFORMATI ON Ifthismanualanditstroubleshooting&servicesectiondonot solveyourproblems,technical assistancemaybeobtainedfrom:  Teledyne API, Technical Support 9480 Carroll Park Drive San Diego, California 92121-5201USA Toll-free Phone: 8[...]

  • Page 74

    Model 633 Aethalometer ® Bla ck Carbon Monitor User Manual Teledyne Advanced Polluti on Instrumentation 72 07645A DCN6170 Thispageintentionallyleftblank.[...]

  • Page 75

    07645A DCN6170 73 7 SPARE PARTS LIST Following is a list of spare parts availabl e for order through the Sales Department: DU0000146 Filter Tape for 633 DU0000196 Flow calibration pad TU0000034 Static dissipativ e inlet tubing (8-ft) DU0000148 PM2.5 inlet at 5-lpm KIT0000400 Inlet mounting kit WR0000008 Power Cord WR0000101 RS-232 Cable (6-ft) WR00[...]