Teledyne GFC7000EU manual

1
2
3
4
5
6
7
8
9

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Teledyne GFC7000EU, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Teledyne GFC7000EU one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Teledyne GFC7000EU. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Teledyne GFC7000EU should contain:
- informations concerning technical data of Teledyne GFC7000EU
- name of the manufacturer and a year of construction of the Teledyne GFC7000EU item
- rules of operation, control and maintenance of the Teledyne GFC7000EU item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Teledyne GFC7000EU alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Teledyne GFC7000EU, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Teledyne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Teledyne GFC7000EU.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Teledyne GFC7000EU item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 1 MODEL GFC7000EU CO 2 ANALYZER (Addendum to GFC7000E Manual PN 04584) Teledyne Analytical Instruments 16830 Chestnut St. City of Industry, Ca. 91748 TEL: 626-961-9221 FAX: 626-961-2538 TEL: 626-934-1500 E-MAIL: ai-customerservice@teledyne.com WEB SIT[...]

  • Page 2

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 2 OVERVIEW The model GFC7000EU is a close derivative of the Model GFC7000E CO Analyzer. The optical bench is longer (14 m), making the instrument more sensitive at low CO 2 levels. The instrument has a user selectable full scale range of 0-100 PPB to [...]

  • Page 3

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 3 Humidity Range 0-95% RH, Non-Condensing Temp Coefficient < 0.05 % of reading per ° C (5 ppb/ ° C minimum) (6) Voltage Coefficient < 0.05 % of reading per V Dimensions (HxWxD) 7" x 17" x 23.5" (178 mm x 432 mm x 597 mm) Weight [...]

  • Page 4

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 4 There are 4 relay alarm outputs (AL1-AL4) on the rear panel. AL1 is for system okay, AL2 is for concentration limit 1 exceeded and AL3 is for concentration limit 2 exceeded. The relay alarm output AL1 is enabled all the time, whereas the AL2 and AL3[...]

  • Page 5

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 5 SAMPLE WHEEL TEMP WARNING CO = XX.XX TEST CAL MSG CLR SETUP Make SURE warning messages are NOT due to LEGITIMATE PROBLEMS. . Press CLR to clear the message currently being Displayed. If more than one warning is active the next message will take its [...]

  • Page 6

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 6 Warning Message Fault Condition Possible Causes FRONT PANEL WARN The CPU is unable to Communicate with the Front Panel Display /Keyboard WARNING only appears on Serial I/O COM Port(s) Front Panel Display will be frozen, blank or will not respond. ?[...]

  • Page 7

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 7 Warning Message Fault Condition Possible Causes on wheel rotation.  Failed Sync/Demod Board If Status LED’s on the Sync/Demod Board ARE flashing the cause is most likely an a problem with the analyzer’s main power:  Intermittent loss of th[...]

  • Page 8

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 8 #N05ATI 009690000 Filter, TFE, 47 mm 5 um, Qty 100 009690100 Filter, TFE, 47 mm 5 um, Qty 25 009820200 Assy, Motor, Synchronous, 115V/60HZ, "E" 010790000 Input Mirror 010800000 Output Mirror 016290000 Window, Sample Filter, 47 mm 016910000[...]

  • Page 9

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) 05134 Rev - 9 OR0000001 O-Ring, Flow Control OR0000058 O-Ring, Sample Filter, 47 mm, 2-228V OR0000034 O-Ring, Input/Output Mirror/Detector OR0000039 O-Ring, Window OR0000041 O-Ring, Field and Objective Mirror 043590100 Pump, 115V 50/60 Hz PU0000022 Pump Rebuild K[...]