Thermador VTN420B manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Thermador VTN420B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Thermador VTN420B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Thermador VTN420B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Thermador VTN420B should contain:
- informations concerning technical data of Thermador VTN420B
- name of the manufacturer and a year of construction of the Thermador VTN420B item
- rules of operation, control and maintenance of the Thermador VTN420B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Thermador VTN420B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Thermador VTN420B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Thermador service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Thermador VTN420B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Thermador VTN420B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    READ AND SA VE THESE INSTRUCTIONS INST ALLA TION INSTRUCTIONS HS-HST -HSB W ALL HOODS APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONL Y PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave t[...]

  • Page 2

    Page 2 IMPORTANT SAFETY INSTRUCTIONS CAUTION: FOR GENERAL VENTI- LATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VA- PORS. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the [...]

  • Page 3

    Page 3 IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE. a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b ) Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzet[...]

  • Page 4

    Page 4 ATTENTION: SEULEMENT POUR L’UTILISATION D’AÉRATION. NE PAS L’UTILISER POUR ÉPUISER LA VAPEUR OU LES MATIÈRES EXPLOSIVES OU DANGEREUSES. AVERTISSEMENT - POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE, OU DE LA BLESSURE AUX PERSONNES, OB- SERVER LE SUIVANT: A . Utiliser cet appareil seulement dans la manière destinée par [...]

  • Page 5

    Page 5 LES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES AVERTISSEMENT - POUR RÉDUIRE LE RISQUE D’UN FEU DE GRAISSE DU SOMMET DE LA CUISINIÈRE: 1 . Garder le ventilateur, les filtres et les surfaces chargées de la graisse propres. 2 . Toujours mettre le capot EN MARCHE en cuisinant à la haute chaleur. 3. Utiliser les hauts positionnements du cuisini[...]

  • Page 6

    Page 6 Parts Included with your Hood • Hood Canopy Assembly with Light Bulbs Installed  Care & Use /Installation Instructions  Registration Card  Filters, 2, 3 or 4 depending on model and size  Metal Transition with Back draft dampers installed (On HST Series hoods it is temporarily fixed for shipping inside the hood with two scre[...]

  • Page 7

    Page 7 BEFORE INSTALLING HOOD 1. For the most efficient air flow exhaust, use a straight run or as few elbows as possible. CAUTION: Vent unit to outside of building, only. 2. Almost two people are necessary for installation. 3. The hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if the[...]

  • Page 8

    Page 8 H OO D W I D T H D I M. "A" 30" 12 - 3/16" 36" 15 - 3/16" 42" 18 - 3/16" 48" 21 - 3/16" HOO D DE P TH DIM . " B " 30" 22 - 11/16" 36" 23" 42" 23 - 5/16" 48" 23 - 7/ 8" Note: It is important to select the ventilator to be used before cutting th[...]

  • Page 9

    Page 9 TYPICAL INSTALLATION The hoods are designed for either vertical or horizontal discharge as shown in Figure A and B respectively. The height from the countertop to the bottom of the hood is 30" to 36”.These hoods are not recommended to be used over indoor grills. DUCTING Provide a Round Duct having a diameter of 8 (see Figure A and [...]

  • Page 10

    Page 10 plate fixing point Plate Figure 3 Discharge Direction: The hood is shipped ready for horizontal discharge. To change to vertical discharge move plate to the rear side and ventilator (if supplied) to the top side. The plate and ventilator are held in place by four nuts each, see also Figures 3 and ,at page 9, Figure A and Figure B. Read also[...]

  • Page 11

    Page 11 closed. Wall Mount Installation - HS and HSB series only. (see Figure 5) 1. After the hood installation height has been determined draw a horizontal line at a distance above the cooktop equal to the desired hood installation height plus 7- 1/2” . 2. Find the centerline of the cooktop. Draw a vertical line along this centerline up to the h[...]

  • Page 12

    Page 12 Wall Mount Installation - HST series Hood only (see Figure 6-7-8) 1. Hood Installation Height After the hood installation height has been determined draw a horizontal line at a distance above the cooktop equal to the desired hood installation height plus 16 1/2. This line is the mounting location of the wooden bracket shipped with the ho[...]

  • Page 13

    Page 13 three or four studs as available. Countersink the heads to pre- vent interference with the hood. 8. On the wood bracket mark the locations used to hang the hood according to Figure 7. 9. Drill a 1/8 tap hole through the wooden bracket and drywall. These screws do not need to go into the studs. 10. Screw 2 (4.2mm x 18 mm) screws into the [...]

  • Page 14

    Page 14 Cabinet Installation: (Figure 5) Note: distances on page 10, Table 3. 1. Find the centerline of the cabinet bottom. Draw a line along this centerline from rear to front of the cabinet. 2. Draw two lines, one at a K distance from the wall, the other one at a Z distance from the previous line. Mark 4 points , two along each line at a distance[...]

  • Page 15

    Page 15 From Control Panel Motor connector VTN 420 or VTN 620 Wiring the HOOD with an IntegralVentilator: Warning: Turn off electricity at the service panel before wiring the unit. 1. Connect the Integral Ventilator molex plug connector to the connector present inside the hood as shown in Figure 9 o r Figure 10 . 2. Remove the j-box cover as shown [...]

  • Page 16

    Page 16 REMOTE VENTILATOR INSTALLATION Models VTR600R or VTR1000Q (Only HS and HST Series Hood): The hood is designed to work with Thermadors remote ventilator (see list under paragraph  Parts Not Included with your Hood ). For installation instructions see the instructions supplied with the ventilator unit. Wiring the Hood with a Remote V[...]

  • Page 17

    Page 17 Assembly and Installation of the Duct Covers (HS and HSB Series Hood only): Optional duct covers shown in Fig- ure 14 may be used to fill the space between the hood and ceiling in wall mount installations. 6 and 12 high duct covers are available and may be ordered separately. 1. If multiple duct covers are used, connect the pieces tog[...]