Trane GAT2A0C60S51SA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Trane GAT2A0C60S51SA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane GAT2A0C60S51SA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Trane GAT2A0C60S51SA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Trane GAT2A0C60S51SA should contain:
- informations concerning technical data of Trane GAT2A0C60S51SA
- name of the manufacturer and a year of construction of the Trane GAT2A0C60S51SA item
- rules of operation, control and maintenance of the Trane GAT2A0C60S51SA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane GAT2A0C60S51SA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane GAT2A0C60S51SA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane GAT2A0C60S51SA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane GAT2A0C60S51SA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Modular Multi-position Air Handler s GA T2A0B42S31SA GA T2A0C48S41SA GA T2A0C60S51SA PUB. NO . 22-1857-03[...]

  • Page 2

    2 Pub . No. 22-1857-03 Featur es and Benefits © 2012 T rane • Unique Cabinet Design - Double Wall F oamed and F or med Cabinet System - W ater Proof Cabinet Design - R-4.2 Insulating V alue (A vg. Insulating V alue R-8.2) - Composite F oamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Cabinet Design - Smooth Cl[...]

  • Page 3

    Pub . No . 22-1857-03 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benets 5 General Data 6 GA T2A0B42S31SA 6 GA T2A0C48S41SA 6 GA T2A0C60S51SA 6 P erformance Data 7 Electrical Data 10 Wiring Diagrams 13 Field Wiring 15 Con ver tibility 17 Dimensions 18[...]

  • Page 4

    4 Pub . No. 22-1857-03 Optional Equipment Accessory Number Description Fits Cabinet Size BA YEAA C05BK1A Electric Heater , 5kW , Breaker , 24V Control, 1 Ph A to C BA YEAA C05LG1A Electric Heater , 5kW , Lugs, 24V Control, 1 Ph A to C BA YEAA C08BK1A Electric Heater , 8kW , Breaker , 24V Control, 1 Ph A to C BA YEAA C08LG1A Electric Heater , 8kW , [...]

  • Page 5

    Pub . No . 22-1857-03 5 Unique Cabinet Design Featur es and Benefits 5 Conduit Connections e Integrated Horizontal Drain P ans 6 T ool-less Door Fastener s w Compact 20.8” Depth with Doors Remo ved 1 Unique Cabinet Design 2 Precision Durable Door Seals 0 Thermal Expansion V alve (TXV) 3 Refrigeration Connections 8 All Aluminum Coil r Safety Door[...]

  • Page 6

    6 Pub . No. 22-1857-03 General Data 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI ST ANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for perf ormance data. 2 3/4" Male Plastic Pipe (Ref .: ASTM 1785-76) 3 Constant torque Motor PRODUCT SPECIFICA TIONS MODEL R[...]

  • Page 7

    Pub . No . 22-1857-03 7 General Data AIRFLO W PERFORMANCE GA T2A0B42S31SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 1646 1495 1358 1522 1298 1138 0.1 1599 1464 1335 1489 1285 1137 0.2 1546 1421 1313 1449 1260 1120 0.3 1488 1380 1280 1401 1233 1099 0.4 1425 1329 1233 1348 119[...]

  • Page 8

    8 Pub . No. 22-1857-03 Per for mance Data GA T2A0C48 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GA T2A0C48S41SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 1904 1711 1541 1652 1455 1305 0.1 1881 1687 1529 1640 1450 1288 0.2 1844 1666 1511 1619 1425 1271 0.3 1806 1637 148[...]

  • Page 9

    Pub . No . 22-1857-03 9 Per for mance Data GA T2A0C60 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GA T2A0C60S51SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 5 4 † 3 2 1 5 4 † 3 2 1 0 2169 1956 1874 1739 1633 2165 2033 1871 1736 1629 0.1 2161 1916 1839 1696 1588 2155 1990 1833 1690 1582 0.[...]

  • Page 10

    10 Pub . No . 22-1857-03 Per for mance Data WIRING D A T A GA T2A0B42S31SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 2.7** 3 15 - - 2[...]

  • Page 11

    Pub . No . 22-1857-03 11 Per for mance Data WIRING D A T A GA T2A0C48S41SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 3.1** 4 15 - - 3[...]

  • Page 12

    12 Pub . No . 22-1857-03 Per for mance Data DIST ANCE FROM BELL Y B AND T O SHAFT F A CE OF MO T OR FOR MINIMUM VIBRA TION WHEEL BLO WER HOUSING BELL Y BAND M OTO R A A is determined per char t Wheel is centered in Blower Housing MODEL DIM "A" GA T2A0B42S31SA 3 GA T2A0C48S41SA 2-13/16 GA T2A0C60S51SA 2-1/4 WIRING D A T A GA T2A0C60S51SA H[...]

  • Page 13

    WIRING DIA GRAM FOR GA T2A0B42 AND GA T2A0C48 AIR HANDLERS[...]

  • Page 14

    WIRING DIA GRAM FOR GA T2A0C60 AIR HANDLERS[...]

  • Page 15

    Pub . No . 22-1857-03 15 Field Wiring GA T2 AIR HANDLERS WITH SINGLE SPEED COOLING • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat. Air Handler Hook-up Diagra m Cooling Red Y ellow Green White Blue Y ellow Green White Blue B B - Blue Blue W G Y Y - Y ellow Y ellow R Red O Oran[...]

  • Page 16

    16 Pub . No . 22-1857-03 Field Wiring GA T2 AIR HANDLERS WITH SINGLE SPEED HEA T PUMP • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat Air Handler Hook-up Diagra m HP Red Y ellow Green White Blue Orange Y ellow Green White Blue B B - Blue R - Red W G Y Y - Y ellow R Red O Orang[...]

  • Page 17

    Pub . No . 22-1857-03 17 GA T2 Conver tibility Multi-position Air Handler Airflow Airflow Airflow Upflow Condensate Drains Refrigerant Connections Horizontal Left* V er tical Upflow* (as shipped) Horizontal Right* Horizontal Left Condensate Drains Refrigerant Connections Horizontal Right Condensate Drains Refrigerant Connections * Note: No internal[...]

  • Page 18

    18 Pub . No . 22-1857-03 Dimensions GA T2 AIR HANDLER DIMENSIONAL D A T A D H W Model No . H W D GA T2A0B42 55.7 21.3 21.75 GA T2A0C48 56.9 23.5 21.75 GA T2A0C60 61.7 23.5 21.75 GA T2 AIR HANDLERS ARE ALL TWO PIECE CABINETS.[...]

  • Page 19

    Pub . No . 22-1857-03 19 GA T2 OUTLINE DRA WING MODEL NO . A B C D E F H FLO W CONTROL GAS LINE BRAZE GA T2A0B42 55.7 45.5 18.4 21.3 18.4 9.2 24.8 TXV 7/8 GA T2A0C48 56.9 46.7 20.5 23.5 20.5 10.3 24.2 TXV 7/8 GA T2A0C60 61.7 51.5 20.5 23.5 20.5 10.3 27.0 TXV 7/8[...]

  • Page 20

    T rane 6200 T roup Highway T yler , TX 75707 www .trane .com 03/12 The manuf acturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.[...]