Go to page of
Similar user manuals
-
Thermostat
Trane XL950
32 pages 8.36 mb -
Air Conditioner
Trane Unit Control Module (UCM) 4.2 Retrofit Model VAV
8 pages 0.23 mb -
Heat Pump
Trane WCY036G1
20 pages 1.17 mb -
Air Conditioner
Trane FTXS15DVJU
30 pages 1.73 mb -
Heat Pump
Trane WC-IOM-7
60 pages 0.99 mb -
Refrigerator
Trane CVGF
24 pages 0.39 mb -
Furnace
Trane UX1B060A9361A
40 pages 1.37 mb -
Gas Heater
Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace
16 pages 0.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Trane RTHD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane RTHD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Trane RTHD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Trane RTHD should contain:
- informations concerning technical data of Trane RTHD
- name of the manufacturer and a year of construction of the Trane RTHD item
- rules of operation, control and maintenance of the Trane RTHD item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane RTHD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane RTHD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane RTHD.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane RTHD item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Ser ies R ™ Helical Rotary Liquid Chillers Model RTHD 1 75-450 T ons (60 Hz) 125-450 T ons (50 Hz) Built f or Industr ial and Commer cial Applications RLC-PRC020-EN June 2006[...]
-
Page 2
RLC-PRC020-EN © 2004 American Standard Inc. All rights reserved. Intr oduction T o meet a wide range of applications in the medium-tonnage, water -cooled market, T rane is proud to introduce the model R THD helical rotary liquid c hiller . The introduction of this next-generation c hiller an exciting step forward in application versatility, ease o[...]
-
Page 3
3 RLC-PRC020-EN Contents Intr oduction F eatur es and Benefits Options Contr ols Application Considerations Selection Pr ocedur e Model Nomenclat ur e Gener al Data Electr ical D ata and Connections Dimensions and W eights Mechanical Specifications Con version T able 2 4 6 8 10 12 14 16 19 22 29 30[...]
-
Page 4
RLC-PRC020-EN 4 F eatures and Benef its Applications in this catalog specifically excluded from the ARI certification program are: • Low temperature applications, including ice storage • Glycol • 50Hz units below 200 nominal tons Application V ersatility and High Performance • Screw compressor tec hnology and the electronic expansion valve [...]
-
Page 5
5 RLC-PRC020-EN F eatures and Benef its State-of-the-Art, Precision Control • Microprocessor -based CH530 controls monitor and maintain optimal operation of the c hiller and its associated sensor s, actuator s, relays, and switc hes, all of whic h are factory-assembled and extensively tested. • Easy interface with computers hosting T racer Summ[...]
-
Page 6
RLC-PRC020-EN 6 Options Insulation All low temperature surfaces are covered with factory installed 3/4 inc h (1 9.05 mm) Armaflex II or equal (k=0.28) insulation, including the evaporator and water boxes, suction line, and motor housing. 3/8" foam insulation is used on the liquid level sensor and gas pump assembly , including piping. Low -T em[...]
-
Page 7
7 RLC-PRC020-EN Control Options: T racer Summit Communications Link to factory-installed, tested communication board, via single twisted- pair wiring, adds T racer Summit communications to the system. LonT alk LCI-C Interf ace LonT alk (LCI-C) communications capabilities are available, with communication link via single twisted-pair wiring to facto[...]
-
Page 8
RLC-PRC020-EN 8 LCD T ouc h-Screen Displa y with Multi-Language Support The standard DynaView display provided with the CH530 control panel features an LCD touc h-screen, allowing access to all operational inputs and outputs. This display supports eleven languages: English, Chinese, Dutc h, Frenc h, German, Italian, Japanese, Korean, Portugese, Spa[...]
-
Page 9
9 RLC-PRC020-EN Contr ols T rane Chiller Plant A utomation T rane’ s depth of experience in c hillers and controls makes us a well-qualified choice for automation of c hiller plants using air - cooled S eries R ® c hiller s ® . The chiller plant control capabilities of the T rane T racer Summit ® building automation system are unequaled in the[...]
-
Page 10
RLC-PRC020-EN 10 Condenser W ater T emperatur es Reduced sensitivity to condenser water startup temperatures is one major enhancement in the newest-generation water -cooled Series R c hiller . With the model RTHD c hiller , a condenser water control method is necessary only if the unit starts with entering water temperatures below 55°F (12.8°C), [...]
-
Page 11
11 RLC-PRC020-EN Ser ies Chiller Ar rangements Another energy-saving strategy is to design the system around c hillers ar ranged in series, on the evaporator , condenser , or both. The actual savings possible with suc h strategies depends on the application dynamics and should be researc hed by consulting your T rane Systems Solutions Representativ[...]
-
Page 12
RLC-PRC020-EN 12 S election P r ocedure T rane Series R c hiller performance is rated in accordance with the ARI Standard 550/590-2003 Certification Program. Chiller selection assistance and performance information can be obtained by using the Series R c hiller selection program, available through local T rane sales offices. Performance The compute[...]
-
Page 13
13 RLC-PRC020-EN Electr ical Data T ables Compressor motor electrical data is provided in the data section for eac h compressor size. Rated load amperes (RLA), loc k ed rotor wye amperes (LRA) and expected inrush for the Wye-delta and Solid State Starter configurations are shown. Although the terms “LRA ” and “ expected inrush” are of ten u[...]
-
Page 14
RLC-PRC020-EN 14 Model Nomenclature RTH D U D 2 F 0 A0 U A G 3 A 4 L A L G 3 F 2 L A L 1 , 2 , 3 4 5 6 7 8 9 1 0 , 1 1 1 21 3 1 41 5 1 6 1 7 1 81 9 2 02 1 2 22 32 4 2 52 6 2 7 Digits 0 1, 02, 03 – Ser ies R ™ RTH = Series R Digit 04 – Dev Sequence D = 4th Major Development Digit 05 – Design Control U = WCBU Digit 06 – Compressor Frame B =[...]
-
Page 15
15 RLC-PRC020-EN Model Nomenclature A V X Q X E X A A B D Y 444 D A X A 4 X X X R X V X 2 8 2 9 3 0 3 1 3 2 33 3 4 3 5 3 6 37 3 8 3 9 40,41,42 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 0 51 5 2 5 3 5 4 Digit 28 – Condenser Leaving Water T emperature A = Standard Digit 29 – Refrigerant Specialties X = No Refrigerant Isolation V alves V = With Refrigerant Is[...]
-
Page 16
RLC-PRC020-EN 16 Nominal Data Nominal Compressor B1 B2 C1 C2 D 1 D 2 D 3 E 3 T onnage (60 Hz) 175-200 200-225 225-275 275-325 325-400 375-450 N/ A N/A T onnage (50 Hz) 125-150 150-175 175-225 225-275 275-325 300-350 325-375 375-450 Notes: 1 . Chiller selections can be optimized through the use of the ARI-Certified Series R selection program and by [...]
-
Page 17
17 RLC-PRC020-EN General Data Minimum/Maximum Evaporator Flow Rates (Gallons/Minute ) T wo P a s s Three Pass Four Pass Evaporator Nominal Nominal Nominal Code Min Ma x Conn Size (In.) M i n M a x Conn Size (In.) M i n M a x Conn Size (In.) B 1 253 1 10 4 8 168 736 6 —- — - — - B2 28 8 1266 8 1 92 84 4 6 —- —- —- C1 32 0 1412 8 21 3 94 [...]
-
Page 18
RLC-PRC020-EN 18 Minimum/Maximum Evaporator Flow Rates (GPM) T wo P a s s Three Pass Four Pass Evaporator Nominal Nominal Nominal Code Min Max Conn Size (In.) M i n M a x Conn Size (In.) M i n M a x Conn Size (In.) B 1 303 1 10 4 8 200 736 6 —- — - — - B2 34 6 1266 8 2 33 84 4 6 —- —- —- C1 34 6 1412 8 2 54 94 1 6 —- —- —- C2 37 5[...]
-
Page 19
19 RLC-PRC020-EN Electrical Data and Connections Compressor Motor Electrical Data (60 Hertz) Nominal V oltage 20 0 2 30 3 80 4 60 57 5 Compressor V oltage 18 0/ 208/ 342/ 414/ 516/ Code Utilization Range 2 20 2 54 4 1 8 50 6 63 3 Max kW 1 74 1 74 1 7 4 1 7 4 17 4 B1, B2 RLA @ Max kW 5 57 4 84 2 91 2 41 1 93 LRA Y 970 818 488 400 329 LRAD 3103 2617 [...]
-
Page 20
RLC-PRC020-EN 20 Electrical Data and Connections[...]
-
Page 21
21 RLC-PRC020-EN Electrical Data and Connections[...]
-
Page 22
RLC-PRC020-EN 22 Shipping and Operating W eights Compressor Evaporato r Condenser Operating W eight Shipping W eight Code Code Code ( l b s ) (kg) (lbs) (kg) B1 B1 B1 9,867 4,476 9,292 4,215 B1 C1 D 1 10,554 4,787 9,837 4,462 B2 B2 B2 1 0 ,0 19 4,545 9,402 4,265 B2 C2 D 2 10,653 4,832 9,953 4,515 C1 D 6 E 5 13,397 6,077 12,780 5,797 C1 D 5 E 4 13,6[...]
-
Page 23
23 RLC-PRC020-EN Dimensions and W eights BBB Configuration Recommended Clearances Front 36" (914 mm) Back 36" (914 mm) Either End 36" (914 mm) Other End* 108" (2743 mm) T o p 36" (914 mm) * Clearance for tube removal Note: 1 . Dimensions are based on 3 Pass Evap / 2 P ass Cond and LH/LH water connections. Refer to submittal[...]
-
Page 24
RLC-PRC020-EN 24 Dimensions and W eights BCD Configuration Recommended Clearances Front 36" (914 mm) Back 36" (914 mm) Either End 36" (914 mm) Other End* 126" (3200 mm) T o p 36" (914 mm) * Clearance for tube removal Note: 1 . Dimensions are based on 3 Pass Evap / 2 Pass Cond and LH/LH water connections. Refer to submittals[...]
-
Page 25
25 RLC-PRC020-EN Dimensions and W eights CDE, DDE, EDE Configuration Recommended Clearances Front 36" (914 mm) Back 36" (914 mm) Either End 36" (914 mm) Other End* 108" (2743 mm) T o p 36" (914 mm) * Clearance for tube removal Note: 1 . Dimensions are based on 3 Pass Evap / 2 P ass Cond and LH/LH water connections. Refer to[...]
-
Page 26
RLC-PRC020-EN 26 Dimensions and W eights CEF Configuration Recommended Clearances Front 36" (914 mm) Back 36" (914 mm) Either End 36" (914 mm) Other End* 126" (3200 mm) T o p 36" (914 mm) * Clearance for tube removal Note: 1 . Dimensions are based on 3 Pass Evap / 2 Pass Cond and LH/LH water connections. Refer to submittals[...]
-
Page 27
27 RLC-PRC020-EN Dimensions and W eights CFF , DFF , EFF Configur ation Recommended Clearances Front 36" (914 mm) Back 36" (914 mm) Either End 36" (914 mm) Other End* 126" (3200 mm) T o p 36" (914 mm) * Clearance for tube removal Note: 1 . Dimensions are based on 3 Pass Evap / 2 P ass Cond and LH/LH water connections. Refer[...]
-
Page 28
RLC-PRC020-EN 28 Dimensions and W eights DGG, EGG Configuration Recommended Clearances Front 36" (914 mm) Back 36" (914 mm) Either End 36" (914 mm) Other End* 126" (3200 mm) T o p 36" (914 mm) * Clearance for tube removal Note: 1 . Dimensions are based on 3 Pass Evap / 2 Pass Cond and LH/LH water connections. Refer to submi[...]
-
Page 29
29 RLC-PRC020-EN Mec hanical Specif ications General Exposed metal surfaces are painted with air -dry beige, direct-to-metal, single- component paint. Eac h unit ships with full operating c harges of refrigerant and oil. Molded neoprene isolation pads are supplied for placement under all support points. Startup and operator instruction by factory-t[...]
-
Page 30
RLC-PRC020-EN 30 Con v er sion T able[...]
-
Page 31
31 RLC-PRC020-EN[...]
-
Page 32
T rane has a policy of continuous product and product data impro vement and reserves the right to change design and specifications without notice. Literature Order Number File Number Supersedes Stocking Location T rane A business of American Standar d Companies www .tr ane.com For more information, contact your local sales office or e-mail us at co[...]