The rules should oblige the seller to give the purchaser an operating instrucion of Trane XV 90, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane XV 90 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Trane XV 90. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Trane XV 90 should contain:
- informations concerning technical data of Trane XV 90
- name of the manufacturer and a year of construction of the Trane XV 90 item
- rules of operation, control and maintenance of the Trane XV 90 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane XV 90 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane XV 90, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane XV 90.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane XV 90 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Upflo w/Horizontal T w o-sta ge Condensing Gas-Fired Furnace XV 90 TUY060,080,100,120R9V V ariable Speed Blo wer V ariable Speed Inducer PUB. NO . 22-1682-05-0802 (EN) TDD-D-1[...]

  • Page 2

    2 Pub. No. 22-1682-05-0802 (EN) General Features © 2002 American Standard Inc. All Rights Reserved NA TURAL GAS MODELS Central heating furnace designs are cer tified b y the Inter national Approv al Services (IAS) for both natural and L.P . gas . Limit setting and rating data were established and appro ved under standard rating conditions using Am[...]

  • Page 3

    3 Pub. No. 22-1682-05-0802 (EN) Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V P erformance Data Electrical Data Field Wiring Dimensions 2 4 6 7 11 12 15[...]

  • Page 4

    4 Pub. No. 22-1682-05-0802 (EN) XV 90 ST AND ARD EQUIPMENT Features and Benefits • Variable speed indoor blower • Silicon Nitride Igniter with adaptive heat up • Variable speed induced draft blower • Direct/Non-Direct vent option • Fused 24 volt control circuit • Manual reset burner safety switches • Power supply 115/1/60 • Converti[...]

  • Page 5

    5 Pub. No. 22-1682-05-0802 (EN) Features and Benefits OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... T A YS T A T241 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................[...]

  • Page 6

    6 Pub. No. 22-1682-05-0802 (EN) TUY-R9V PRODUCT SPECIFICA TIONS 1 MODEL RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE (ICS) T emp. Rise (Min.-Max.) °F . BLO WER DRIVE Dia.-Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts/Ph/Hz COMBUSTION F AN -[...]

  • Page 7

    7 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data *UY060 R9V3V FUR NA CE COOLING AIRFL O W (CFM) AND PO WE R (W A TT S) VS. EX TERNAL ST A TIC PRESSUR E WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFL OW SETTI NG DIP SWITC H SETTING EXTERN AL ST A TIC PR ESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0. 7 0.9 1.5 LOW (350 CFM/T ON ) ON ON OFF ON CFM WA T TS [...]

  • Page 8

    8 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY080 R9V3V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0 .5 0.7 0.9 2.0 LO W (350 CFM/T ON) ON ON OFF ON C[...]

  • Page 9

    9 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY100 R9V4V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0 .5 0.7 0.9 3.0 LO W (350 CFM/T ON) ON ON OFF ON C[...]

  • Page 10

    10 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY120 R9V5V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0 .5 0.7 0.9 3.5 LO W (350 CFM/T ON) OF F ON OFF O[...]

  • Page 11

    11 Pub. No. 22-1682-05-0802 (EN) SCHEMA TIC DIAGRAMS FOR GAS FURNA CES TUY060,080,100,120R9V -V LEGEND Electrical Data From Dwg. 21D341111 P03[...]

  • Page 12

    12 Pub. No. 22-1682-05-0802 (EN) TO 115 V 1 PH., 60 HZ., POWER SUPPL Y PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING F rom Dwg. 21B341127 Rev . 0 F rom Dwg. 21B341126 Rev . 0 FIELD WIRING DIA GRAM FOR 2 ST A GE HEA TING THERMOST A T TO 115 V 1 PH., 60 HZ., POWER SUPPL Y PER LOCAL CODES [...]

  • Page 13

    13 Pub. No. 22-1682-05-0802 (EN) Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg. 21B341125 Rev . 1 F rom Dwg. 21B341124 Rev . 1 FIELD WIRING DIA GRAM FOR 2 ST A GE HEA TING SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER)[...]

  • Page 14

    14 Pub. No. 22-1682-05-0802 (EN) Field Wiring FIELD WIRING DIA GRAM FOR 2 ST A GE HEA TING TWO ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg. 21B341128 Rev . 0 TO 115 V 1 PH., 60 HZ., POWER SUPPL Y PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5[...]

  • Page 15

    15 Pub. No. 22-1682-05-0802 (EN) Dimensions TUY-R9V -V OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES)[...]

  • Page 16