Go to page of
Similar user manuals
-
Power Supply
Tripp Lite INTERNET550U
1 pages 0.12 mb -
Power Supply
Tripp Lite UPS System AVRX550U
2 pages 0.32 mb -
Power Supply
Tripp Lite SUPDM56HW
2 pages 0.11 mb -
Power Supply
Tripp Lite AGSM4878
13 pages 0.42 mb -
Power Supply
Tripp Lite SmartPro SMART2200CRMXL
6 pages 0.13 mb -
Power Supply
Tripp Lite 200803016 95-2924
8 pages 3.03 mb -
Power Supply
Tripp Lite MRV2012UL
4 pages 0.14 mb -
Power Supply
Tripp Lite 3-Phase 10kVA
76 pages 2.47 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Tripp Lite 200703028, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Tripp Lite 200703028 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Tripp Lite 200703028. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Tripp Lite 200703028 should contain:
- informations concerning technical data of Tripp Lite 200703028
- name of the manufacturer and a year of construction of the Tripp Lite 200703028 item
- rules of operation, control and maintenance of the Tripp Lite 200703028 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Tripp Lite 200703028 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Tripp Lite 200703028, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Tripp Lite service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Tripp Lite 200703028.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Tripp Lite 200703028 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Owner’ s Man ual 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 • www .tripplite.com Impor tant Safety Instructions 2 Installation 3 Basic Operation 7 Battery Replacement 13 Storage and Service 14 Smar tOnline ™ Rack/T ower Mount On-Line UPS Systems Pure Sine Wa ve Output • 220/230/240V Input/Output Español Fran[...]
-
Page 2
UPS Location W arnings • Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight. • For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C). • Leave adequate space around all sides of the UPS for proper ventilation. • Do not mount unit with its fro[...]
-
Page 3
Mount your equipment in either a 4-post or 2-post rack or rack enclosure (see next page for 2- post mounting). The user must determine the fitness of hardware and procedures before mounting. If hardware and procedures are not suitable for your application, contact the manufacturer of your rack or rack enclosure. The procedures described in this man[...]
-
Page 4
INPUT BREAKER INPUT BREAKER ACC. SLOT LOAD 1 IN PHONE / DAT A PROTECTION OUT EPO LOAD 2 OUT P RS-232 USB CAUTION Risk of electric s h See top of unit fo cautionary marki n Y our model may diff er. 1 2a Y our model may diff er. 4 Installation (continued) 2-P ost (T elecom) Mounting If you mount 2U UPS models in 2-post racks, they require the additio[...]
-
Page 5
5 Impor tant Safety Instructions Connection and Start-Up (continued) T urn the UPS ON: • Press the ON/TEST Switch and hold it for several seconds until you hear a beep • Release the ON/TEST Switch. The ON LINE LED will illuminate, and your UPS will begin providing power to its AC outlets Note: After initial installation of the UPS or after prol[...]
-
Page 6
6 Optional Connections (continued) USB and RS-232 Serial Communications Use the included USB cable (see ) and/or DB9 serial cable (see ) to connect the communication port of your computer to the communication port of your UPS. Install on your computer the T ripp Lite PowerAlert Software appropriate to your computer's operating system. Y our UP[...]
-
Page 7
7 Front P anel Switches “ON/TEST” Button: This switch controls four separate UPS functions: UPS Power ON T o turn the UPS on, press this button, hold it for several seconds until you hear a beep, then release it. The “ON LINE” LED will illuminate. UPS Self-T est During normal on-line operation, press this button and hold it until you hear a[...]
-
Page 8
8 Front P anel Indicator Lights continued “BYP ASS” LED: This yellow light will flash to indicate that the UPS’ s DC/AC inverter is deactivated and the UPS is in the “Bypass” mode. During normal operation this LED will light briefly when the unit is plugged in, but if an internal fault or overload occurs this light will flash constantly t[...]
-
Page 9
9 Rear Panel “REPLACE BA TT” LED: This red light will illuminate constantly an d the UPS alarm will beep every 2 seconds if your UPS’ s microprocessor detects a battery fault or if your UPS fails the automatic self-test (after you turn your UPS ON) and the UPS battery is less than fully charged. Let the UPS system char ge for at least 12 hour[...]
-
Page 10
Rear Panel continued Input Cord Connection: This IEC320-C20 or IEC320-C14 inlet enables the UPS to be connected to an AC power source via a user-supplied cord with country-specific plug. See "Connection and Start-Up". AC Receptacles (V aried by Model): These receptacles provide your connected equipment with pure sine-wave AC output from t[...]
-
Page 11
11 The UPS’ s control panel lights will turn on in the sequences below to signal that the UPS is having operational difficulties. Lights (On/Flashing) and Condition Solution On: REPLA CE B A TT Let the UPS system charge f or at least Condition: Replace Battery 12 hours and perf orm a self test using the "ON/T est Switch" as described on[...]
-
Page 12
12 T r oubleshooting (continued) Lights (On/Flashing) and Condition Solution On: BYP ASS, LINE Check the UPS to be sure that there is Flashing: F A UL T adequate space f or air to circulate near Condition: On Bypass due to High the vents and that the f an is working Internal T emperature properly . Restar t the UPS. Flashing: LINE This indicates th[...]
-
Page 13
13 Battery Replacement Under normal conditions, the original batteries in your UPS will last many years. See "Important Safety Instructions" before replacing ba tteries. The batteries are designed for hot- swap replacement (i.e. leaving the UPS in ON mode), but some qualified service personnel may wish to put the UPS in the OFF mode and d[...]
-
Page 14
Regulatory Compliance Identification Numbers: For the purpose of regulatory compliance certifications and identification, your T ripp Lite product has been assigned a unique series number . The series number can be found on the product nameplate label, along wit h all required approval markings and information. When requesting compliance informatio[...]
-
Page 15
1111 W . 35th Street, Chicago, IL 60609 USA 773.869.1234 (USA) • 773.869.1212 (International) www .tripplite.com 200703028 93-2486_EN[...]