Go to page of
Similar user manuals
-
Ventilation Hood
Vermont Casting 43LDVT
40 pages 4.63 mb -
Ventilation Hood
Vermont Casting 3976
44 pages 0.89 mb -
Ventilation Hood
Vermont Casting DVRSL
35 pages 0.74 mb -
Ventilation Hood
Vermont Casting 4070
44 pages 0.89 mb -
Ventilation Hood
Vermont Casting DVA4136
1 pages 0.17 mb -
Ventilation Hood
Vermont Casting DVR33
40 pages 0.93 mb -
Ventilation Hood
Vermont Casting SDVR
44 pages 0.89 mb -
Ventilation Hood
Vermont Casting LHERDV20
32 pages 1.94 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vermont Casting LHER20, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vermont Casting LHER20 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vermont Casting LHER20. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vermont Casting LHER20 should contain:
- informations concerning technical data of Vermont Casting LHER20
- name of the manufacturer and a year of construction of the Vermont Casting LHER20 item
- rules of operation, control and maintenance of the Vermont Casting LHER20 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vermont Casting LHER20 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vermont Casting LHER20, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vermont Casting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vermont Casting LHER20.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vermont Casting LHER20 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
10005360 5/06 Rev . 5 Natural V ent Insert Models: LHER20 LHEC20 LHER30 LHEC30 D E S I G N C E R T I F I E D CERTIFIED DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not [...]
-
Page 2
2 10005360 LHE Ser ie s N atur al V ent I nser t T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace insert. IMPORT ANT - Read all instructions and warnings carefully before starting installation. Failure to follow[...]
-
Page 3
3 10005360 LHE Ser ie s N atur al V ent I nser t This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S. Installations follow local codes and/or the current National Fuel Gas Code ANSI Z223.1/NFP A 54. [...]
-
Page 4
4 10005360 LHE Ser ie s N atur al V ent I nser t N O P E M F 5360 LHE ac spces 5/03 U S R Q V T FP1248 Minimum fireplace opening 1/03 Q - Fireplace opening height R - Fireplace opening width S - Depth of insert T - Firebox width at insert depth(S) LHEC20 LHER20 LHEC30 LHER30 A-1 20 ⁷⁄₈ " (530 mm) 20 ⁷⁄₈ " (530 mm) 26 ³[...]
-
Page 5
5 10005360 LHE Ser ie s N atur al V ent I nser t When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes appli- cable to woodburning fireplaces. Consult local authori- ties having jurisdiction for these clearances. For applications requiring th[...]
-
Page 6
6 10005360 LHE Ser ie s N atur al V ent I nser t Natural LP Minimum Inlet Pressure 5.5" W . C . 1 1.0" W . C . Maximum Inlet Pressure 14.0" W . C . 14.0" W . C . Manifold Pressure 3.5" W . C . 10.0" W . C . Gas Inlet & Manifold Pressures Do not use this appliance if any part of it has been under water . Immediately[...]
-
Page 7
7 10005360 LHE Ser ie s N atur al V ent I nser t FP297 INST A VENT FREE R MODEL GAS SUPPL Y 8/24/96 1/2" Gas Supply 1/2" x 3/8" Shut Off V alve 3/8" Nipple 3/8" Union FP297 Fig. 4 T ypical gas supply installation. 3/8" Nip- ple Gas Supply Pressures This heater must be isolated from the gas supply piping system by closi[...]
-
Page 8
8 10005360 LHE Ser ie s N atur al V ent I nser t Installer must attach red warning plate with screws supplied with the gas fireplace insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed. Cutting any sheet metal parts of the fire- place, in which the gas fireplace insert is to be installed, is p[...]
-
Page 9
9 10005360 LHE Ser ie s N atur al V ent I nser t Zero clearance kit minimum clearance to combustibles materials is 1" (25 mm) for B V ent (use of single wall vent is not allowed.) As with any natural drafted appliances, the vent cap must always extend a minimum of 2' (610 mm) above any structure within a 10' (3 m) horizontal plane. ([...]
-
Page 10
10 10005360 LHE Ser ie s N atur al V ent I nser t Ceramic Refractory Installation 1. Remove front glass. 2. Remove logs from unit. 3. Remove refractory from package. Refractory are fragile and must be handled with care. Where at all possible, two hands should be used when handling. 4. T ake center refractory and tilt so bottom edge seats onto the r[...]
-
Page 11
1 1 10005360 LHE Ser ie s N atur al V ent I nser t Operating Instructions General Glass Information Only ceramic glass approved by CFM Cor- poration may be used for replacement on this unit. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. 3. Under no circumstances should this ap[...]
-
Page 12
12 10005360 LHE Ser ie s N atur al V ent I nser t First Firing Upon completing the gas line connec- tion, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge themselves of this air . Once the purging is complete, the pilot and burner will light and operate as indicated in the i[...]
-
Page 13
13 10005360 LHE Ser ie s N atur al V ent I nser t F584-703 Honeywell & PSE pilot flames 3/8" - 1/2" SIT Pilot PSE Pilot F584-703 Fig. 22 Correct pilot flame appearance. L O H I Turn counterclockwise to increase flame height. Turn clockwise to lower flame height. FP390 FLAME ADJUSTMENT KNOB 11/21/96 SIT V alve [...]
-
Page 14
14 10005360 LHE Ser ie s N atur al V ent I nser t 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to " OFF ". Do not force. 5. Close control access panel. 1. ST OP! Read the safety information above. 2. T urn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on to [...]
-
Page 15
15 10005360 LHE Ser ie s N atur al V ent I nser t W ARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off electrode at pilot. pilot and push the red button again. If pilot will n[...]
-
Page 16
16 10005360 LHE Ser ie s N atur al V ent I nser t Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Depressing Piezo — 1/8" Gap To Pilot Hood Needed. All Wiring Connections Replace Piezo Ignitor For Air In The Lines Thermopile Needs A Minimum 32[...]
-
Page 17
17 10005360 LHE Ser ie s N atur al V ent I nser t Instructions for RF C om fo rt C on tr o l Va lv e The Comfort Control V alve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal. Operation 1. If the manual switch is in remote position, switch it to LOCAL. (Fig. 25) 2.[...]
-
Page 18
18 10005360 LHE Ser ie s N atur al V ent I nser t Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. T o change the timer level, press the time key followed by an arrow key . Pushing the key once will change the timer by 10 minutes. Auto Mode In the AUTO mode, the room temperature, set tem- perature, ?[...]
-
Page 19
19 10005360 LHE Ser ie s N atur al V ent I nser t LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 T urn fan ON NOTE: Some keys are not active. 2. Slide the Remote/Local switch to REMOTE and teach the valve a tr[...]
-
Page 20
20 10005360 LHE Ser ie s N atur al V ent I nser t Light pilot burner Set manual switch to local or remote Release pilotstat knob T urn pilotstat knob from PILOT to ON If manual switch is set to LOCAL, did main burner light? T ransmitter con- trols fan T urn pilotstat knob to PILOT to turn off main burner T urn pilotstat knob to OFF to turn valve co[...]
-
Page 21
21 10005360 LHE Ser ie s N atur al V ent I nser t Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this[...]
-
Page 22
22 10005360 LHE Ser ie s N atur al V ent I nser t LHER20/LHEC20 1a 1d 1b 1e LHER30/LHEC30 1a 1d 1c 1e 1b 3 2 4 5 6a/b 7a/b 9 a/b 8a/b 19 14 16 18 10a/b 18 17 1 1a/b 12a/b 13a/b 15 20 23 a/b 21 22a/b LOCAL REMOTE ON • PILOT OFF • LED 24a/b 25 26 27 28/29 30 31 32 33 35 34[...]
-
Page 23
23 10005360 LHE Ser ie s N atur al V ent I nser t LHE Series (continued) Ref. Description LHER20 LHEC20 LHER30 LHEC30 1. Log Set Complete 10005332 10005332 10004866 10004866 1a. Log Rear Left 10005333 (JR7) 10005333 (JR7) 10004874 (KR22) 10004874 (KR22) 1b. Log Rear Right 10005334 (JR8) 10005334 (JR8) 10004875 (KR23) 10004875 (KR23) 1c. Log Rear Ce[...]
-
Page 24
24 10005360 LHE Ser ie s N atur al V ent I nser t Ref. Description LHER20 LHEC20 LHER30 LHEC30 LHE Series (continued) 37. Remote Switch (for RN or RP Units) 53606 53606 53606 53606 38. Remote Wire Harness w/T erminals (for RN or RP Units) 10002582 10002582 10002582 10002582 39. Ceramic Fiber Brick FP (Optional) JT1TR0 JT1TC0 KT1TR0 KT1TC0 40. Brack[...]
-
Page 25
25 10005360 LHE Ser ie s N atur al V ent I nser t Optional Accessories Remote Controls Optional remote control units are available to control different functions of the appliance. Model Function(s) Controlled RC1 ON/OFF RC2 ON/OFF and T emperature MRC3 ON/OFF and T emperature control with a digital and a programmable 24 hour clock IMT W all mounted[...]
-
Page 26
26 10005360 LHE Ser ie s N atur al V ent I nser t Modification Instructions of EP28-5 Series Fireplace Upgrading to LHEC20 or LHER20 Natural V ent Insert W ARNING: Y ou must turn off gas supply to fireplace. 1. Remove the upper and lower trims. 2. Remove the doors and mesh firescreen, if installed. 3. Remove the bottom door rail. (Fig. 28) 4. Di[...]
-
Page 27
27 10005360 LHE Ser ie s N atur al V ent I nser t BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and [...]
-
Page 28
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) LHEC20RN 51.2 71 75 60 LHEC20RP 51.2 72 76 60 LHEC20RFN 51.2 71 75 60 LHEC20RFP 51.2 72 76 60 LHER20RN 51.0 69 N/A 59 LHER20RP 51.0 70 N/A 59 LHEC30RN 48.5 69 72 64 LHEC30RP 48.5 70 73 64 LHEC30RFN 48.5 69 72 64 LHEC30RFP 48.5 70 73 [...]