A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vinotemp WINE-MATE VINO1500HZD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vinotemp WINE-MATE VINO1500HZD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vinotemp WINE-MATE VINO1500HZD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vinotemp WINE-MATE VINO1500HZD should contain:
- informations concerning technical data of Vinotemp WINE-MATE VINO1500HZD
- name of the manufacturer and a year of construction of the Vinotemp WINE-MATE VINO1500HZD item
- rules of operation, control and maintenance of the Vinotemp WINE-MATE VINO1500HZD item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vinotemp WINE-MATE VINO1500HZD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vinotemp WINE-MATE VINO1500HZD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vinotemp service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vinotemp WINE-MATE VINO1500HZD.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vinotemp WINE-MATE VINO1500HZD item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
WINE-MATE Cooling Unit Use & Care Manual VINO1500HZD VINO2500HZD VINO3500HZD VINO4500HZD VINO6500HZD VINO8500HZD V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p . . w w w w w w . . v v i i n n o o t t e e m m p p . . c c o o m m w w w w w w . . w w i i n n e e m m a a t t e e . . c c o o m m[...]
-
Page 2
- 1 - Important Safety Information • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 20 OR 30 AMPCIRCUIT IS REQUIRED (1500-4500HZD OR 6500-8500HZD).[...]
-
Page 3
- 2 - TABLE OF CONTENTS Features & Specifications.…………………….……………..3 Installation Instruction………………………………………..5 Temperature Control & Humidity Adjustment...………..13 Care Guide…………………………………………………… .16 Troubleshooting………………………[...]
-
Page 4
- 3 - Features and Specifications • HZD cooling unit is designed and us ed to provide a stable temperature between 50~65 ° F for suitable space at a normal environment. • The refrigerated space will mainta in humidity of 50~70% RH even when the environment becomes dry and humid. • These temperatures and humilities ar e optimized for long ter[...]
-
Page 5
- 4 - Fig. 1.2 DIMENSIONS The dimension and capacity are specified as follows: MODEL CFM CAPACITY cu ft (55 ° F/75 ° F) DIMENSIONS W”XD”XH” ELECTRICAL WEIGHT (lb) VINO-1500HZD 120 90 14.25X16X13.25 115V/60HZ/4A 50 VINO-2500HZD 180 200 14.25X16X13. 25 115V/60HZ/5A 55 VINO-3500HZD 250 650 14.25X21. 25 X19.75 115V/60Hz/6A 75 VINO-4500HZD 250 1[...]
-
Page 6
- 5 - Installation Instruction Select a place to mount the unit where t he exhaust airflow is unobstructed for a minimum of 6 inch. The area into which t he unit exhausts must be well ventilated. If it is not, heat exhaust ed by the unit will build up and the unit will not operate properly. The ambient temperatur es shall not be higher than 78 ° F[...]
-
Page 7
- 6 - • If top exhaust, place another gaskets al ong the top exhaust at the top of the cooling unit (see Fig.2.3). • Move the cooling unit towards the m ounting sides and push to press the gaskets (see Fig 2.5). • Fasten the 2 brackets and use 7/16” wrench to tighten t he two ¼” screws (see Fig 2.6). • Attach the exhaust and fresh air [...]
-
Page 8
- 7 - Fig. 2.2 GASKET Fig. 2.3 TOP EXHAUST GASKET[...]
-
Page 9
- 8 - Fig. 2.4 THREAD INSERT Fig. 2.5 COOLING UNIT[...]
-
Page 10
- 9 - Fig. 2.6 FASTENING BRACKET & SCREW[...]
-
Page 11
- 10 - Fig. 2.7 CABINET GRILLE 2. VINO3500-8500HZD THROUGH WALL INSTALLATION • Cut a rectangular opening at the win e room wall as illustrated. The dimensions of the opening shall be 1/4” larger than the width and height of the unit. • If top exhaust, cut another rectangular ope ning at the top of the cabinet to the length and width of the to[...]
-
Page 12
- 11 - • Attach the molding to the wall not the unit. • Plug the unit into a properly gr ounded and dedicated outlet of adequate capacity. Fig. 2.8 THROUGH WALL INSTALLATION Fig. 2.9 TOP EXHAUST GASKET[...]
-
Page 13
- 12 - 3. Cellar Construction This is only a guide and shall be c onsidered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier s hall be installed on the warm side of the insula[...]
-
Page 14
- 13 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantit y of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize th[...]
-
Page 15
- 14 - 2.1 LED Functions LED MODE FUNCTION ON Compressor enabled Flashing Anti-short cycle enabled ON Defrost cycle enabled ON Fan enabled Flashing Fan delay after defrost enabled ON Alarm occurring ON Temperature measuring unit Flashing Programming mode 3) Alarm Signals 3.1 Code Description MESSAGE CAUSE FUNCTION P1 Temperature probe faulty Compre[...]
-
Page 16
- 15 - 5) Parameter Programming 1. Press the SET + keys for 3 sec until the “ °C” or “°F” LED starts blinking, then release the keys. 2. Press again the SET + keys for more th an 7sec until the Pr2 label will be displayed, then release the keys. The first parameter Hy will be displayed. 3. Press up/down keys / to select the required param[...]
-
Page 17
- 16 - Care Guide 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Coil is on the ambient air intake side of the cooling unit. • Unplug the unit or disconnect power. • Use a condenser brush or a vacuum cleaner with an extend ed attachment to clean the coil when it is dusty or dirt[...]
-
Page 18
- 17 - Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration servic e person, not is it comprehensive Complaint Possible Causes Response 1. Unit not running a. Power cord unplugged b. No power to unit c. Setting higher than ambient temperature d. Differential too high e. Incorre[...]
-
Page 19
- 18 - l. Failed components l. Check comp ressor windings, sta rt relay and overload protector 5. Unit running too long a. Improper room insulation & seal b. Exhaust restricted c. Room too large d. Ambient temperature higher > 90 ° F e. Dir ty C ondenser a. Check for insulation, gasket and door opening b. Leave minimum 3 feet clearance for [...]
-
Page 20
- 19 - 11. Evaporator freezing up a. Evaporator air flow restricti on b. Not stopping due to air leak, high ambient temperature or low setting c. Low ambient temperature d. Bad thermostat or sensor e. Moisture in the system f. Refrigerant low or le aking g. Capillary tube blockage a. Check for fans & CFM b. Check for seal, door opening, ambient[...]
-
Page 21
- 20 - Wiring Diagram Fig. 6.1 VINO1500-2500H ZD Wiring Diagram Fig. 6.3 VINO3500-8500H ZD Wiring Diagram[...]
-
Page 22
- 21 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com[...]
-
Page 23
- 22 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and se rial numbers in the space provided: Model____________________ ____________________ _________________ Serial No._________________ ____________________ _________________ Attach your purchase receipt to this owner’s manual. 1. Limited Warranty VINO[...]
-
Page 24
- 23 - is determined to be faulty and is within the twelve month warranty period VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation o[...]