Vulcan-Hart ML-103838 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vulcan-Hart ML-103838, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vulcan-Hart ML-103838 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vulcan-Hart ML-103838. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vulcan-Hart ML-103838 should contain:
- informations concerning technical data of Vulcan-Hart ML-103838
- name of the manufacturer and a year of construction of the Vulcan-Hart ML-103838 item
- rules of operation, control and maintenance of the Vulcan-Hart ML-103838 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vulcan-Hart ML-103838 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vulcan-Hart ML-103838, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vulcan-Hart service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vulcan-Hart ML-103838.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vulcan-Hart ML-103838 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    – 1 – 1024,1036,1048 CHEESEMEL TER MODELS 1024C ML-103833 1024W ML-103834 1024P ML-103835 1036C ML-103836 1036W ML-103837 1036P ML-103838 1048C ML-103839 Canadian ML-126600 1048W ML-103840 Canadian ML-126602 1048P ML-103841 Canadian ML-126601 INST ALLA TION & OPERA TION MANU AL Model 1024 In Canada: HOBART FOOD EQUIPMENT GROUP CANADA 190 RA[...]

  • Page 2

    – 2 –[...]

  • Page 3

    – 3 – © VULCAN-HART COMPANY, 1998 T ABLE OF CONTENTS GENERAL ............................................................................................................................................. 4 Specifications ........................................................................................................................... 4[...]

  • Page 4

    – 4 – OPERA TION & INST ALLA TION MODELS 1024,1036,1048 CHEESEMEL TERS PLEASE KEEP THIS MANUAL FOR FUTURE USE GENERAL Vulcan-Hart Cheesemelters are produced with quality workmanship and material. Proper installation, usage, and maintenance of your cheesemelter will result in many years of satisfactory performance. Thoroughly read this entir[...]

  • Page 5

    – 5 – INST ALLA TION UNPACKING This cheesemelter was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage. If the cheesemelter is found to be damaged, save the packaging material and contact [...]

  • Page 6

    – 6 – INSTALLATION CODES AND STANDARDS The cheesemelter must be installed in accordance with: In the United States of America: 1. State and local codes. 2. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. In Canada: 1. Local codes.[...]

  • Page 7

    – 7 –[...]

  • Page 8

    – 8 – HEATER INSTALLATION 1. Push one end of the heater into one socket as far as it will go. 2. Swing the other end of heater up until it lines up with the opposite socket. 3. Release heater and it will snap into place. 4. Grasp the heater and move it back and forth to ensure that it is centered correctly. 5. Rotate the heater clockwise, then [...]

  • Page 9

    – 9 – ELECTRICAL CONNECTIONS WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT. Two 1" (25 mm) knockouts ar[...]

  • Page 10

    – 10 – OPERA TION WARNING: THE CHEESEMELTER AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING, OR SERVICING THE CHEESEMELTER. 1. Push the main switch to ON. • Pilot lights. • Cooling fan runs. 2. Place the product on the front of the rack. The heaters will automatically come on full power. • If the heaters do not come on ful[...]

  • Page 11

    – 11 – TROUBLESHOOTING IF THE CHEESMELTER BLOWS A FUSE OR TRIPS A CIRCUIT BREAKER 1 . Check the capacity of the circuit. 2 . Contact your local Hobart Food Equipment Group office. IF THE HEATERS DO NOT LIGHT 1 . If the pilot light does not come on, and the cooling fan does not run, check for a blown fuse or an open circuit breaker. 2 . If the p[...]

  • Page 12

    – 12 – NOTES[...]

  • Page 13

    – 1 – SALAMANDRES 1024, 1036 ET 1048 MODÈLES 1024C ML-103833 1024W ML-103834 1024P ML-103835 1036C ML-103836 1036W ML-103837 1036P ML-103838 1048C ML-103839 Canada ML-126600 1048W ML-103840 Canada ML-126602 1048P ML-103841 Canada ML-126601 MODE D’EMPLOI Modèle 1024 F33225B (599) IMPRIMÉ AUX É.-U. Au Canada : GROUPE HOBART CANADA ÉQUIPEME[...]

  • Page 14

    – 2 –[...]

  • Page 15

    – 3 – © VULCAN-HART COMPANY, 1998 T ABLE DES MA TIÈRES GÉNÉRALITÉS .................................................................................................................................... 4 Caractéristiques ....................................................................................................................... 4[...]

  • Page 16

    – 4 – CARACTÉRISTIQUES MODÈLE 1024C 1024W 1024P 1036C 1036W 1036P 1048C 1048W 1048P DIMENSIONS Largeur 686 686 686 927 927 927 1270 1270 1270 mm (po) (27) (27) (27) (36 1/2) (36 1/2) (36 1/2) (50) (50) (50) Profondeur 438 438 406 438 438 406 438 438 406 mm (po) (17 1/4) (17 1/4) (16) (17 1/4) (17 1/4) (16) (17 1/4) (17 1/4) (16) Hauteur 489 3[...]

  • Page 17

    – 5 – INST ALLA TION DÉBALLAGE Cet appareil a été inspecté avant de quitter l’usine. En acceptant de livrer cette marchandise, le transporteur en assume l’entière responsabilité jusqu’à la livraison. Immédiatement après avoir déballé l’appareil, vérifier s’il n’a pas été endommagé lors du transport. En cas de dommages[...]

  • Page 18

    – 6 – CODES D’INSTALLATION ET NORMES L’installation de ces salamandres doit se faire selon les codes suivants : Aux États-Unis : 1. Codes locaux. 2. Norme ANSI/NFPA n° 70 (dernière édition) du National Electrical Code disponible auprès de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Au Canada : 1. Codes[...]

  • Page 19

    – 7 – APPAREIL ISOLANT PANNEAU ARRIÈRE TIRE-FONDS VIS DE RETENUE DU PANNEAU ARRIÈRE[...]

  • Page 20

    – 8 – INSTALLATION DES ÉLÉMENTS CHAUFFANTS 1. Enfoncer une des extrémités de l’élément chauffant aussi loin que possible dans une douille. 2. Aligner l’autre extrémité avec la douille opposée. 3. Relâcher l’élément chauffant et il s’enclenche en place. 4. Saisir l’élément et lui imprégner un mouvement de va-et-vient pou[...]

  • Page 21

    – 9 – RACCORDEMENT ÉLECTRIQUE AVERTISSEMENT : LE RACCORDEMENT ÉLECTRIQUE ET LA MISE À LA TERRE DOIVENT ÊTRE CONFORMES AUX NORMES CONCERNÉES DU CODE CANADIEN DE L’ÉLECTRICITÉ OU DE TOUT AUTRE CODE D’ÉLECTRICITÉ EN VIGUEUR. AVERTISSEMENT : COUPER L’ALIMENTATION ÉLECTRIQUE DE L’APPAREIL ET APPOSER UNE ÉTIQUETTE AU DISJONCTEUR PO[...]

  • Page 22

    – 10 – FONCTIONNEMENT AVERTISSEMENT : LA SALAMANDRE ET SES COMPOSANTS SONT CHAUDS. EXERCER UNE EXTRÊME PRUDENCE LORS DE SON UTILISATION, NETTOYAGE ET ENTRETIEN. 1. Mettre l’interrupteur général sous tension. • Le voyant s’allume. • Le ventilateur se met en marche. 2. Déposer le produit sur la partie avant de la grille. Les élément[...]

  • Page 23

    – 11 – DÉP ANNA GE FUSIBLE GRILLÉ OU DISJONCTEUR DÉCLENCHÉ 1. Vérifier la capacité du circuit. 2. Communiquer avec le service de l’entretien Hobart le plus près. LES ÉLÉMENTS CHAUFFANTS REFUSENT DE S’ALLUMER 1. Si le voyant refuse de s’allumer et que le ventilateur ne fonctionne pas, s’assurer qu’aucun fusible n’est grillé[...]

  • Page 24

    – 12 – NO T A[...]