York AFFINITY R-410A manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of York AFFINITY R-410A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York AFFINITY R-410A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of York AFFINITY R-410A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of York AFFINITY R-410A should contain:
- informations concerning technical data of York AFFINITY R-410A
- name of the manufacturer and a year of construction of the York AFFINITY R-410A item
- rules of operation, control and maintenance of the York AFFINITY R-410A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York AFFINITY R-410A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York AFFINITY R-410A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York AFFINITY R-410A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the York AFFINITY R-410A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 333495-YTG-C- 0908 TECHNICAL GUIDE Description These York ® Affinity ™ packaged heat pump s are designed for outdoor installation. Only ut i lity and duct connections are required at the point of installation. Field-installed electric he ater accessories are availabl e to prov[...]

  • Page 2

    333495-YTG-C-0908 2 Johnson Controls Unitary Products Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 3

    333495-YTG-C-0908 Johnson Controls Unitary Products 3 Nomenclature Heat Pump Features and Benefits Standard Features • Operating Efficiency - All heat pump units provide operating efficiencies of 13 to 15 SEER and 7.7 to 8.0 HSPF. All efficiencies exceed legislated minimum levels. • On Site Flexibility - All model sizes share a co mmon, compact[...]

  • Page 4

    333495-YTG-C-0908 4 Johnson Controls Unitary Products • More Attracti ve Appearanc e - A single piece Water Shed top cover containing a top discharge condenser fan arrangement requires less square foo tage on installation and provides a wider variety of installations. The one piece design adds greater water integrity. Rounded corners with water d[...]

  • Page 5

    333495-YTG-C-0908 Johnson Controls Unitary Products 5 2ET07700224 and 2ET04700224 a re used. Standard in all BHX units. • Filter/Fram e Kit (Sin gle Phase Only) - Kit contains the necessary hardware to field install return air filters into the base unit. Pre-cut filter ra cks and appropriate cleanable standard size filters are shipp ed in one kit[...]

  • Page 6

    333495-YTG-C-0908 6 Johnson Controls Unitary Products Refrigerant Components Compressors: a. Shall be fully herme tic type, direct drive, internally protected with in ternal high-pressure reli ef and over temperature protection. The herme tic motor shall be suction gas cooled an d have a voltage range of +/- 10 % of the unit nameplate voltage. b. S[...]

  • Page 7

    333495-YTG-C-0908 Johnson Controls Unitary Products 7 Physical Data BHZ024-060 Physical Data Component Models BHZ024 BHZ030 BHZ036 BHZ042 BHZ048 BHZ060 Nominal Tonnage 2.0 2.5 3.0 3.5 4.0 5.0 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 22.9 29.7 36.0 41.3 47.2 57.5 ARI net capacity (Btu) 22.8 29.2 33.6 40.5 45.5 56.0 EER 11.4 11.25 1[...]

  • Page 8

    333495-YTG-C-0908 8 Johnson Controls Unitary Products BHX024-060 Physical Data Component Models BHX024 BHX036 BHX048 BHX060 Nominal Tonnage 2.0 3.0 4.0 5.0 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 24.9 35.3 49.2 58.8 ARI net capacity (Btu) 24.4 34.4 47.0 57.0 EER 12.0 11.5 11.3 11.0 SEER 16 15 15 14.5 Nominal CFM 800 1200 1600 170[...]

  • Page 9

    333495-YTG-C-0908 Johnson Controls Unitary Products 9 BHZ and BHX Unit Limitations Size (Tons) Model Unit Voltage Unit Limitation s Applied Voltage Outdoor DB Temp Min Max Max (°F) 024 (2.0) BHZ 208/230-1-60 187 252 125 BHX 208/230-1-60 187 252 115 030 (2.5) BHZ 208/230-1-60 187 252 125 208/230-3-60 187 252 125 460-3-60 432 504 125 036 (3.0) BHZ 2[...]

  • Page 10

    333495-YTG-C-0908 10 Johnson Controls Unitary Products Capacity Performance BHZ024-060 Cooling Capa cities BHZ024 (2.0 Ton) Air on Evaporator Coil Temperature of Air on Condenser Coil Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh ) Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh) CFM WB (°F) Return Dry Bulb (°F) Re[...]

  • Page 11

    333495-YTG-C-0908 Johnson Controls Unitary Products 11 115°F 125°F 600 77 22.6 2.3 12.1 9.2 6.4 - - - 22.5 2.6 12.4 9.5 6.7 - - - 72 20.6 2.3 16.0 13.1 10.3 7.4 - - 19.7 2.5 15.7 12.8 10.0 7.1 - - 67 18.6 2.3 18.6 17.0 14.1 11.3 8.4 - 16.9 2.5 16.9 16.1 13.3 10 .4 7.6 - 62 17.5 2.3 17.5 17.5 16.0 13.2 10 .3 7.5 15.9 2.5 15.9 15.9 14.7 11.8 9.0 6.[...]

  • Page 12

    333495-YTG-C-0908 12 Johnson Controls Unitary Products BHZ030 (2.5 Ton) Air on Evaporator Coil Temperature of Air on Condenser Coil Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh ) Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh) CFM WB (°F) Return Dry Bulb (°F) Return Dry Bulb (°F) 90 85 80 75 70 65 90 85 80 75 70[...]

  • Page 13

    333495-YTG-C-0908 Johnson Controls Unitary Products 13 115°F 125°F 750 77 29.2 3.1 13.8 10.2 6.7 - - - 26.0 3.3 12.5 8.9 5.3 - - - 72 26.4 3.1 18.6 15.1 11.5 7.9 - - 23.4 3.4 17.5 13.9 10.4 6.8 - - 67 23.7 3.2 23.5 19.9 16.3 12.8 9.2 - 20.8 3.5 20.8 19.0 15.4 11 .8 8.3 - 62 22.1 3.1 22.1 21.7 18.1 14.6 11 .0 7.4 20.5 3.4 20.5 20.2 16.6 13.1 9.5 5[...]

  • Page 14

    333495-YTG-C-0908 14 Johnson Controls Unitary Products BHZ036 (3.0 Ton) Air on Evaporator Coil Temperature of Air on Condense r Coil Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh) Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh ) CFM WB (°F) Return Dry Bulb (°F) Return Dry Bulb (°F) 90 85 80 75 70 65 90 85 80 75 7[...]

  • Page 15

    333495-YTG-C-0908 Johnson Controls Unitary Products 15 115°F 125°F 900 77 34.1 3 .9 18.5 14.2 9 .9 - - - 31.2 4.4 16.9 12.6 8.3 - - - 72 30.5 3 .8 24. 0 19.7 15.4 11 .1 - - 27.3 4. 3 22.4 1 8.1 13.8 9 .6 - - 67 26.8 3.7 26.8 25.2 20.9 16.6 12 .3 - 23.5 4.2 23.5 23.5 19.3 15 .1 10.8 - 62 25.7 3.7 25.7 25.7 23 .1 18.9 14 .6 10.3 22.7 4.1 22.7 22.7 [...]

  • Page 16

    333495-YTG-C-0908 16 Johnson Controls Unitary Products BHZ042 (3.5 Ton) Air on Evaporator Coil Temperature of Air on Condenser Coil Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh ) Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh) CFM WB (°F) Return Dry Bulb (°F) Return Dry Bulb (°F) 90 85 80 75 70 65 90 85 80 75 70[...]

  • Page 17

    333495-YTG-C-0908 Johnson Controls Unitary Products 17 115°F 125°F 1050 77 36.6 4.1 21.7 16.7 11.7 - - - 33.6 4.3 21.1 16.1 11.2 - - - 72 32.6 4.0 28.7 23.7 18.7 13.7 - - 29.0 4.3 27.5 22.6 17.6 12.6 - - 67 28.7 3.9 28.7 28.7 25.7 20.7 15 .7 - 24.4 4.2 24.4 26.0 24.0 19.0 14.0 - 62 27.4 3.9 27.4 27.4 27.4 22. 4 17.5 12.5 24.3 4.1 24.3 24.3 24.3 1[...]

  • Page 18

    333495-YTG-C-0908 18 Johnson Controls Unitary Products BHZ048 (4.0 Ton) Air on Evaporator Coil Temperature of Air on Condenser Coil Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh ) Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh) CFM WB (°F) Return Dry Bulb (°F) Return Dry Bulb (°F) 90 85 80 75 70 65 90 85 80 75 70[...]

  • Page 19

    333495-YTG-C-0908 Johnson Controls Unitary Products 19 115°F 125°F 1200 77 47.0 4.1 27.1 21.4 15.7 - - - 42.2 4.5 26.3 20.6 14.9 - - - 72 41.5 4.0 34.9 29.2 23.5 17.8 - - 36.5 4.3 34.1 28.4 22.7 17.0 - - 67 36.0 4.0 36.0 36.0 31.4 25.7 20 .0 - 30.9 4.0 30.9 30.9 30.6 24.9 19.2 - 62 35.4 3.9 35.4 35.4 35.0 29.2 23 .5 17.8 31.2 4.0 31.2 31.2 31.2 2[...]

  • Page 20

    333495-YTG-C-0908 20 Johnson Controls Unitary Products BHZ060 (5.0 Ton) Air on Evaporator Coil Temperature of Air on Condenser Coil Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh ) Net Capacity 1 (MBh) Total Input (kW) 2 Sensible Capacity (MBh) CFM WB (°F) Return Dry Bulb (°F) Return Dry Bulb (°F) 90 85 80 75 70 65 90 85 80 75 70[...]

  • Page 21

    333495-YTG-C-0908 Johnson Controls Unitary Products 21 115°F 125°F 1500 77 52.2 6.2 27.9 20.8 13.7 - - - 46.7 6.6 26.3 19.2 12.1 - - - 72 47.9 6.1 36.8 29.7 22.6 15.5 - - 42.0 6.5 33.6 26.5 19.4 12.2 - - 67 43.5 5.9 43.5 38.6 31.5 24.3 17 .2 - 37.2 6.4 37.2 33.8 26.7 19.5 12.4 - 62 40.2 5.8 40.2 40.2 39.4 32.3 25 .1 18.0 34.7 6.2 34.7 34.7 34.7 2[...]

  • Page 22

    333495-YTG-C-0908 22 Johnson Controls Unitary Products BHX024-060 Cooling Capacities BHX024 (2.0 Ton) Air on Evaporator Coil Temperature of Air on Condense r Coil Net Capacity 1 (MBh) 1. These capacities are Net Capacities. Total Input (kW) 2 2. These ratings include the compressor, co ndenser fan and supply air blower motors. Sensible Capacity (MB[...]

  • Page 23

    333495-YTG-C-0908 Johnson Controls Unitary Products 23 BHX036 (3.0 Ton) Air on Evaporator Coil Temperature of Air on Condense r Coil Net Capacity 1 (MBh) 1. These capacities are Net Capacities. Total Input (kW) 2 2. These ratings include the compressor, co ndenser fan and supply air blower motors. Sensible Capacity (MBh) Net Capacity 1 (MBh) Total [...]

  • Page 24

    333495-YTG-C-0908 24 Johnson Controls Unitary Products BHX048 (4.0 Ton) Air on Evaporator Coil Temperature of Air on Condenser Coil Net Capacity 1 (MBh) 1. These capacities are Net Capacities. Total Input (kW) 2 2. These ratings include the compressor, co ndenser fan and supply air blower motors. Sensible Capacity (MBh ) Net Capacity 1 (MBh) Total [...]

  • Page 25

    333495-YTG-C-0908 Johnson Controls Unitary Products 25 BHX060 (5.0 Ton) Air on Evaporator Coil Temperature of Air on Condense r Coil Net Capacity 1 (MBh) 1. These capacities are Net Capacities. Total Input (kW) 2 2. These ratings include the compressor, co ndenser fan and supply air blower motors. Sensible Capacity (MBh) Net Capacity 1 (MBh) Total [...]

  • Page 26

    333495-YTG-C-0908 26 Johnson Controls Unitary Products Heating Capacities BHZ024-060 Size (Tons) Air Over Evaporator Coil Capacity 1 & kW 2 Outdoor Temperature (°F @ 72% RH) CFM DB (°F ) -10 0 10 20 30 40 50 60 024 (2.0) 600 55 MBH 4.86 6.37 8.30 10.78 13 .98 18.11 23.43 30.30 KW 1.29 1.37 1.45 1.52 1.60 1.67 1.75 1.82 70 MBH 2.79 4.28 6.21 8[...]

  • Page 27

    333495-YTG-C-0908 Johnson Controls Unitary Products 27 036 (3.0) 900 55 MBH 11.61 13.92 16.68 19.98 23.94 28.67 34.32 41.0 9 KW 1.98 2.15 2.32 2.49 2.65 2.82 2.99 3.16 70 MBH 10.65 12.96 15.72 19.02 22.98 27.71 33.37 40.1 4 KW 2.34 2.51 2.68 2.85 3.02 3.19 3.36 3.53 80 MBH 9.30 11.61 14.37 17.67 21.63 26.36 32.02 38.79 KW 2.62 2.79 2.95 3.12 3.29 3[...]

  • Page 28

    333495-YTG-C-0908 28 Johnson Controls Unitary Products 048 (4.0) 1200 55 MBH 17.36 20.44 24.07 28.36 33.44 39.45 46.55 54.9 5 KW 2.47 2.63 2.78 2.93 3.08 3.23 3.39 3.54 70 MBH 15.59 18.66 22.29 26.58 31.66 37.67 44.78 53.1 8 KW 2.93 3.09 3.24 3.39 3.54 3.69 3.85 4.00 80 MBH 14.50 17.57 21.21 25.50 30.58 36.59 43.69 52.0 9 KW 3.29 3.44 3.59 3.75 3.9[...]

  • Page 29

    333495-YTG-C-0908 Johnson Controls Unitary Products 29 BHX024-060 (5.0 Ton) Size (Tons) Air Over Evaporator Coil Capacity 1 & kW 2 1. These Capacities are net capacities - the indoor motor heat has been added. 2. These power inputs are total power inputs - the indoor motor watts have been added. Outdoor Temperature (°F @ 72% RH) CFM DB (°F ) [...]

  • Page 30

    333495-YTG-C-0908 30 Johnson Controls Unitary Products Airflow Performanc e Side Duct Application BHX024-060 Size (Tons) Model Mod e Thermostat Input Speed Tap CFM External Static Pr essure (Inch Water Gauge) 0 . 20 . 30 . 40 . 50 . 60 . 70 . 80 . 91 . 0 Watts Watts Watts Watts Watts Watts Watts Watts Watts 024 (2.0) BHX Cool Low Y1 COOL-A 600 58 7[...]

  • Page 31

    333495-YTG-C-0908 Johnson Controls Unitary Products 31 048 (4.0) BHX Cool Low Y1 COOL-A 1050 184 216 248 280 313 346 380 414 448 Y1 COOL-B 918 138 166 194 224 254 286 31 8 351 385 Y1 COOL-C 984 160 190 220 251 282 315 348 38 1 416 Y1 COOL-D 1115 210 243 277 311 345 3 79 414 449 484 High Y1+Y2 COOL-A 1600 448 500 551 600 647 693 736 779 819 Y1+Y2 CO[...]

  • Page 32

    333495-YTG-C-0908 32 Johnson Controls Unitary Products BHZ024-060 Size (Tons) Model Unit Speed External Static Pressure (Inch Water Gauge) 0.2 0.4 0.6 0.8 1.0 SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM 024 (2.0) BHZ L o w ( 1 ) 7 2 1 8 2 6 0 0 6 1 1 9 7 7 0 5 --------- L o w / M e d i u m ( 2 ) 7 6 9 9 3 6 2 8 6 9 4 1 1 2 7 3 0 6 1 0 1 [...]

  • Page 33

    333495-YTG-C-0908 Johnson Controls Unitary Products 33 Bottom Duct Application BHX024-060 Size (Tons) Model Mod e Thermostat Input Speed Tap CFM External Static Pr essure (Inch Water Gauge) 0 . 20 . 30 . 40 . 50 . 60 . 70 . 80 . 91 . 0 Watts Watts Watts Watts Watts Watts Watts Watts Watts 024 (2.0) BHX Cool Low Y1 COOL-A 600 58 74 91 108 126 143 16[...]

  • Page 34

    333495-YTG-C-0908 34 Johnson Controls Unitary Products 048 (4.0) BHX Cool Low Y1 COOL-A 1050 184 216 248 280 313 346 380 414 448 Y1 COOL-B 918 138 166 194 224 254 286 31 8 351 385 Y1 COOL-C 984 160 190 220 251 282 315 348 38 1 416 Y1 COOL-D 1115 210 243 277 311 345 3 79 414 449 484 High Y1+Y2 COOL-A 1600 448 500 551 600 647 693 736 779 819 Y1+Y2 CO[...]

  • Page 35

    333495-YTG-C-0908 Johnson Controls Unitary Products 35 BHZ024-060 Size (Tons) Model Unit Speed External Static Pressure (Inch Water Gauge) 0.2 0.4 0.6 0.8 1.0 SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM 024 (2.0) BHZ L o w ( 1 ) 7 2 1 8 2 6 0 0 6 1 1 9 7 7 0 5 --------- L o w / M e d i u m ( 2 ) 7 6 9 9 3 6 2 8 6 9 4 1 1 2 7 3 0 6 1 0 1 [...]

  • Page 36

    333495-YTG-C-0908 36 Johnson Controls Unitary Products Additional Static Resistance Size (Tons) Model C FM Wet Indoor Coil Econom izer 1 1. The pressure drop through the economizer is greater for 100 % out door air than for 100% retu rn air. If the resistance of the r eturn air duct is less than 0.25 IWG, the unit will deliv er less CFM during full[...]

  • Page 37

    333495-YTG-C-0908 Johnson Controls Unitary Products 37 Sound Performance Electric Heat Minimum Supply Air Size (Tons) Model Voltage Minimum Supply Air (CFM) Heater kW 5.0 7.5 10.0 15 .0 20.0 25.0 024 (2.0) BHZ BHX 208/230-1-60 630 630 800 - - - 030 (2.5) BHZ 208/230-1-60 630 630 800 80 0 - - 208/230-3-60 630 630 800 80 0 - - 460-3-60 630 630 800 80[...]

  • Page 38

    333495-YTG-C-0908 38 Johnson Controls Unitary Products Electrical Data BHZ024-060 Heat Pump With/Without Electric Heat Size (Tons) Volt Compressors (each) OD Fan Motors (each) Supply Blower Motor Electr i c H e at O pt ion MCA 1 (Amps) 1. Minimum Circuit Ampacity. Max Fuse 2 / Breaker 3 Size (Amps) 2. Maximum Over Current Protection per standard UL[...]

  • Page 39

    333495-YTG-C-0908 Johnson Controls Unitary Products 39 BHX024-060 Heat Pu mp With/Without Electric Heat Size (Tons) Volt Compressors (each) OD Fan Motors (each) Supply Blower Motor Electric Heat Option MCA 1 (Amps) 1. Minimum Circuit Ampacity. Max Fuse 2 / Breaker 3 Size (Amps) 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HAC[...]

  • Page 40

    333495-YTG-C-0908 40 Johnson Controls Unitary Products Typical BHX/BHZ024-060 Wiring Diag rams Typical BHX024, 048 and 060 Heat Pump 20 8/230-1-60 volt Wiring Diagram[...]

  • Page 41

    333495-YTG-C-0908 Johnson Controls Unitary Products 41 Typical BHX036 Heat Pump 208/ 230-1-60 vo lt Wiring Diagram[...]

  • Page 42

    333495-YTG-C-0908 42 Johnson Controls Unitary Products Typical BHZ024-060 Heat Pump 208 /230-1-60 volt Wiring Diagram[...]

  • Page 43

    333495-YTG-C-0908 Johnson Controls Unitary Products 43 Typical BHX048 and 060 Heat Pump 230-3-60 volt Wiring Dia gram[...]

  • Page 44

    333495-YTG-C-0908 44 Johnson Controls Unitary Products Typical BHX036 Heat Pump 2 30-3-60 volt W iring Diagram[...]

  • Page 45

    333495-YTG-C-0908 Johnson Controls Unitary Products 45 Typical BHZ030-060 Heat Pump 230-3-60 vo lt Wiring Diagram[...]

  • Page 46

    333495-YTG-C-0908 46 Johnson Controls Unitary Products Typical BHX048 and 060 Heat Pump 460-3-60 volt Wiring Dia gram[...]

  • Page 47

    333495-YTG-C-0908 Johnson Controls Unitary Products 47 Typical BHX036 Heat Pump 4 60-3-60 volt W iring Diagram[...]

  • Page 48

    333495-YTG-C-0908 48 Johnson Controls Unitary Products Typical BHZ030-060 Heat Pump 460-3-60 vo lt Wiring Diagram[...]

  • Page 49

    333495-YTG-C-0908 Johnson Controls Unitary Products 49 Weights and Dimensions BHX AND BHZ Unit Weights Unit 4 Point Load Weig ht Size (Tons) Model Weight (lbs.) Center of Gravity 4 Point Load Locatio n (lbs.) Shipping Operating X Y A B C D 024 (2.0) BHZ 360 355 22.25 25 96 84 81 93 BHX 385 380 22.25 25 103 90 87 100 030 (2.5) BHZ 355 350 22.25 25 9[...]

  • Page 50

    333495-YTG-C-0908 50 Johnson Controls Unitary Products Heat Pump Unit Dimensions Note: For units applied with a roof curb, the minimu m clear ance may be reduced from 1 inch to 1/2 in ch between combustible roof curb material a nd this supply air duct. Heat Pump Unit Dimensions Unit Size Dimensio ns “A” 024, 036 33-1/2 042 1 , 048, 060 1. BHZ M[...]

  • Page 51

    333495-YTG-C-0908 Johnson Controls Unitary Products 51 Unit Dimensions Front and Bottom Unit Dimensions Back and Bottom 6 19-1/4 1 1-7/8 8-7/8 FRONT GAS SUPPL Y 1-5/8" DIA. KNOCKOUT (1/2" NPTI CONNECTION) LOW VOL T AGE CONN. 7/8" DIA. KNOCKOUT 4-5/8 26-3/4 CONDENSA TE DRAIN 3/4" NPTF HIGH VOL T AGE CONN. 1-3/32" DIA. KNOCKO[...]

  • Page 52

    333495-YTG-C-0908 52 Johnson Controls Unitary Products Unit Typical Duct Applications Unit Typical Slab on Ground Installation ROOF CURB INST ALLA TION REAR DUCT ROOF CURB INST ALLA TION BOTTOM DUCT SLAB ON GROUND INST ALLA TION TO POWER SUPPL Y SUPPL Y AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCA TED TO REAR OF UNIT CONTROL WIRIN[...]

  • Page 53

    333495-YTG-C-0908 Johnson Controls Unitary Products 53 Unit Typical Roof Curb Installation Unit Accessory Dimensions Roof Curb 1 1. 8” Roof Curb also available. SUPPL Y AIR DUCT RETURN AIR DUCT CONTROL WIRING TO INDOOR THERMOST A T TO POWER SUPPL Y FIELD SUPPLIED DISCONNECT SWITCH MOUNTED ON UNIT 1 RECOMMENDED DUCT SIZE 17-1/8" x 21-1/2"[...]

  • Page 54

    333495-YTG-C-0908 54 Johnson Controls Unitary Products Roof Curb Cross Section 1" UNIT BASE RAIL COUNTERFLASHING CANT STRIP INSULA TION AND ROOFING MA TERIAL ROOF DECK AND ROOFING MA TERIAL INSULA TION CURB FRAME 14" 8" MIN. ABOVE FINISHED ROOF WOOD NAILER UNIT BASE 3/4" x 1" WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPO[...]

  • Page 55

    333495-YTG-C-0908 Johnson Controls Unitary Products 55[...]

  • Page 56

    Subject to change without notice. Print ed in U. S.A. 333495-YTG-C-0908 Copyright © 2008 by Johnson Controls, In c. All rights reserved. Supersedes: 333495- YTG-B-0807 Johnson Cont rols Unitary Pr od ucts 5005 York Drive Norman, OK 73069[...]