Go to page of
Similar user manuals
-
Ventilation Hood
Zephyr ALA - E42AWX
27 pages 1.81 mb -
Ventilation Hood
Zephyr AK088xAS
2 pages 0.16 mb -
Ventilation Hood
Zephyr ZRM-E36BS
40 pages 3.87 mb -
Ventilation Hood
Zephyr ZTO-M795
17 pages 0.26 mb -
Ventilation Hood
Zephyr ZVE-E42S
19 pages 0.68 mb -
Ventilation Hood
Zephyr ATI-M90ABX
22 pages 2.06 mb -
Ventilation Hood
Zephyr APN-M90ABX
20 pages 3.26 mb -
Ventilation Hood
Zephyr ASL-E48ASX
23 pages 2.07 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Zephyr AK7842ASX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Zephyr AK7842ASX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Zephyr AK7842ASX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Zephyr AK7842ASX should contain:
- informations concerning technical data of Zephyr AK7842ASX
- name of the manufacturer and a year of construction of the Zephyr AK7842ASX item
- rules of operation, control and maintenance of the Zephyr AK7842ASX item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Zephyr AK7842ASX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Zephyr AK7842ASX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Zephyr service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Zephyr AK7842ASX.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Zephyr AK7842ASX item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © Zephyr Corporation Cypress AK7836ASX AK7842ASX AK7848ASX READ AND SA VE THESE INSTRUCTIONS INTENDED FOR OUTDOOR COVERED P A TIO OR LANAI AREA.[...]
-
Page 2
www .zephyronline.com[...]
-
Page 3
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options .....................[...]
-
Page 4
Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man[...]
-
Page 5
Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat[...]
-
Page 6
List of Materials 4 www .zephyronline.com MODELS: AK7836ASX, AK7842ASX, AK7848ASX P ARTS SUPPLIED 1 - Hood 3 - Baf fl e fi lters (4 for AK7848ASX) 2 - Halogen light bulbs (3 for AK7548ASX) ( pre-installed ) 1 - 10” round transition adapter ( for dual internal and external blowers ) 1 - External blower wiring ( for external and in-line blower ) [...]
-
Page 7
5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow[...]
-
Page 8
Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef fi ciency for single blower and 10” round duct for dual, in-line, and external blowers. Always use rigid type metal ducts only . Flexible ducts could restrict[...]
-
Page 9
7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certi fi ed Silver T ape or Duct T ape. Some Ducting Options Installation ?[...]
-
Page 10
8 www .zephyronline.com Installation – Speci fi cations 35 15/16 ” (36”) 41 15/16 ” (42”) 47 15/16 ” (48”) 12” *10 ” 27” 4” 18” 1 1/8 ” 8 9/16 ” 13 3/16 ” 2 5/16 ” 6 7/16 ” 2” 2 1/16 ” C L 5 9/16” ext blwr k/o elec k/o 2 11 / 1 6 ” top side front 4 5/16 ” *10” transition used with dual, external and in[...]
-
Page 11
9 ELECTRICAL W ARNING All Electrical work must by performed by quali fi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing[...]
-
Page 12
10 www .zephyronline.com C/L C/L A B 12 3/8 ” min 30” 4” wood board fig. 2 fig. 1 Installation – Mounting the Range Hood 1. Measure distance from range top to hood bottom ( 30” min ) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. ( 12 3/8” from line A ) ( This is the top of the board used to hang th[...]
-
Page 13
11 CBI-600B AND PBI-1 100A BLOWER INST ALLA TION 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws. (blower pictured is a PBI-1 100A) 2. Connect male end of blower wire to female plug in the hood. (plug is located inside the hood behind the control panel) 3. Single Blower – [...]
-
Page 14
12 www .zephyronline.com Installation – Remote Blower Preparation 1. Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct work to 10” round adapter . 2. Install threaded end of external blower wiring through external blower wiring knock out located inside the hood. 3. Place cap over threaded end of [...]
-
Page 15
13 Light On/Off By pressing , the light is switched On and Off. is on, is off. Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Lights On/Off Adjust Blower Level (2 Speeds) 1 1 2 2 Switching the rocker switch to middle will turn off the blower. Features & Controls – Rocker Switch Controls[...]
-
Page 16
14 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser . After cleaning, you m[...]
-
Page 17
15 REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. I[...]
-
Page 18
T roubleshooting 16 www .zephyronline.com TROUBLESHOOTING PROCEDURES FOR CYPRESS Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power co[...]
-
Page 19
17 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baf fl e Filter (each) 50210009 Optional Accessories Single Internal Blower CBI-600B Dual Internal Blower PBI-1 100A External Blower CBE-1000 In-Line Blower PBN-1000A Vinyl Cover (36”) AK0636AB Vinyl Cover (42”) AK0642AB Vinyl Cover (48”) AK0648AB 12” Duct [...]