Go to page of
Similar user manuals
-
Ventilation Hood
Zephyr ZSA-M90AS
7 pages 2.02 mb -
Ventilation Hood
Zephyr AHZ-M90ABX
2 pages 0.74 mb -
Ventilation Hood
Zephyr ZVE-E42S
19 pages 0.68 mb -
Ventilation Hood
Zephyr Z1C-01HZ
8 pages 1.38 mb -
Ventilation Hood
Zephyr ZSAM90BS
38 pages 2.47 mb -
Ventilation Hood
Zephyr ZSV-E30AS
7 pages 2.02 mb -
Ventilation Hood
Zephyr Pattern Glass AHG-00BL
12 pages 0.96 mb -
Ventilation Hood
Zephyr ALA - E42AWX
27 pages 1.81 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Zephyr CPA-E48ASX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Zephyr CPA-E48ASX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Zephyr CPA-E48ASX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Zephyr CPA-E48ASX should contain:
- informations concerning technical data of Zephyr CPA-E48ASX
- name of the manufacturer and a year of construction of the Zephyr CPA-E48ASX item
- rules of operation, control and maintenance of the Zephyr CPA-E48ASX item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Zephyr CPA-E48ASX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Zephyr CPA-E48ASX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Zephyr service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Zephyr CPA-E48ASX.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Zephyr CPA-E48ASX item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Use, Care, and Inst allation Guide Model number: Numéro de modèle: ____________________________________ Número de modelo: Serial number: Numéro de série : _____________________________________ Número de serie : Date of Purchase: Date d’achat : _____________________________________ Fecha de compra : Sales Dealer: Détaillant : ______________[...]
-
Page 2
2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST ALLA TION MUST COMPL Y WITH ALL LOCAL CODES. IMPORT ANT : Save these Instructions for the Local Electrical Inspector ’ s use. INST ALLER: Please leave these Instructions with this unit for the owner . OWNER: Please retain these instructions for future reference. Safety W arning: T urn off[...]
-
Page 3
3 www .zephyronline.com T able of Content s Important Safety Notice .................................................................... 5 Electrical & Installation Requirements ............................................ 6 Electrical requirements .............................................................. 6 Before installing the hood .....[...]
-
Page 4
4 Installation - Installing the Duct Covers ......................................... 18 Installation - Hanging the Hood onto the Wall .............................. 19 Installation - Electrical Connection & Final Installation Steps ..... 20 Electrical connection ................................................................ 20 Description of[...]
-
Page 5
5 www .zephyronline.com Import ant Safety Notice CAUTION FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE T O EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR V APORS. W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions,[...]
-
Page 6
6 Electrical & Inst allation Requirement s ELECTRICAL REQUIREMENTS IMPORT ANT Observe all governing codes and ordinances. It is the customer’s responsibility: T o cont act a qualified electrical inst aller . T o assure that the electrical inst allation is adequate and in conformance with National Electrical Code, ANSI/NFP A 70 — latest edit[...]
-
Page 7
7 www .zephyronline.com List of Materials P ARTS SUPPLIED • Hood body , with st ainless steel baf fle filter a nd halogen light bulbs and incandescent lamp already inst alled • T wo telescopic duct covers and support bracket • Hardware Packet: - 24x53 T1T2 "L" Male monkey spanner (1 piece) - 3.5X9.5 screws to fix the internal blower[...]
-
Page 8
8 Dimensions and Clearances Only for version with top discharge feature: * Hood with external motor: Over this measurement a hole may be made on the rear section for the passage of the discharge pipe for connection to the external motor. Consult the template for the passage of pipes under this measurement . ** Ho od with extern al moto r: Ab ove th[...]
-
Page 9
9 www .zephyronline.com Ducting Options and Examples Closely follow the instructions set out in this manual. All responsibility , for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS This range hood is designed to exhaust fumes and vapours towards the outside an[...]
-
Page 10
10 Inst allation - Ductwork Calculation Sheet 3 1/4 ” x 10” Rect., straight 6 ” Round,, straight 7", 8” Round,, straight 3 1/4 ” x 10” Rect.90° elbow 3 1/4 ” x 10” Rect.45° elbow 3 1/4 ” x 10” Rect.90° flat elbow 3 1/4 ” x 10” Rect. wall cap with damper 3 1/4 ” x 10” Rect.to 6 ” round transition 3 1/4 ” x 10?[...]
-
Page 11
11 www .zephyronline.com Inst allation - Preliminary Operations Attention! The installation requires several steps where is asked to temporarily remove some particulars and screws, We recommend to record and keep all of these components in a safe place ready to be used as required. • Remove stainless mesh filters (See relative paragraph on Mainte[...]
-
Page 12
12 Inst allation - Internal Blower Note: for External blower installation disregard the instruction in this page and step ahead on page 14. TOP DISCHARGE (V ertical discharge) The hood is ready to be used for vertical discharge, proceed to install the internal blower (See next page). REAR DISCHARGE (Horizontal discharge) • Remove the internal blo[...]
-
Page 13
13 www .zephyronline.com INTERNAL BLOWER INST ALLA TION • Fit the blower inside the hood. • Install the blower to the support with 4 screws (Provided), check that the rectangular outlet of the blower matches with the rectangular slot of the support. Note: The 4 fixing screws must be screwed in from the outside of the hood (See photo below). •[...]
-
Page 14
14 • Install the supplied round transition collar to the previously installed cover/round transition support plate from inside the hood. Align and att ach with 2 screws securely . Horizontal discharge • From the inside of the hood, remove (rear side) the cover/rectangular transition support unscrewing the 4 screws that fix it to the body of the[...]
-
Page 15
15 www .zephyronline.com • Install the supplied round transition collar to the previously installed cover/round transition support plate. Align and att ach with 2 screws securely . EXTERNAL BLOWER ELECTRICAL CONNECTION - PRELIMINAR Y OPERA TIONS Installing the external blower junction box • Remove the electrical knock out on the upper panel. Se[...]
-
Page 16
16 • T o att ach front p anel to hood body , align the 8 threaded studs through the front bodies corresponding holes. Use 8 wing nuts to attach and secure. See diagrams below 2 3 1 4 6 5 8 7 1 2 3 4 5 6 7 8 3 4 Inst allation - Front Panel NOTE: The front p anel is not supplied with the range hood and must be purchased sep arately . x 8[...]
-
Page 17
17 www .zephyronline.com Inst allation INST ALLING THE HOOD ONT O THE W ALL 1. Disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Use a thick, protective covering over countertop, cooktop or range to protect from damage and debris. Select a flat surface for assembling the unit. Cover that [...]
-
Page 18
18 13. Optional duct cover installation: a. Remove the support bracket from the Duct Cover assembly and attach it to the ceiling with 2 drywall anchors and screws Note: The printed index on the bracket must match the center line previously drawn (See installation step 2 ). Conduit Duct Position reference Position reference CenterLine Duct cover sup[...]
-
Page 19
19 www .zephyronline.com Inst allation - Hanging the Hood onto the W all 14. For internal blower inst allation ONL Y : a. Horizontal (Rear) discharge: Install from the outside the 3 1/4 ” x 10” Rect. transition on the outlet hole of the blower with 3 screws. b. V ertical (Upper) discharge: Install from the outside the 8" plastic round tran[...]
-
Page 20
20 Inst allation - Electrical Connection & Final Inst allation S tep s 18. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service p anel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WIT[...]
-
Page 21
21 www .zephyronline.com Description of the Hood 1 Controls 2 Baffle filter 3 Halogen lamp 4 Incandescent ambient lamp 5 Hood body 6 Duct cover 6 2 2 3 3 4 1 5[...]
-
Page 22
22 Features & Controls - T ouch Controls & Features Use the high suction speed in cases of concentrated kitchen vapors. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes after terminating cooking. Note: Hood retains last speed sett[...]
-
Page 23
23 www .zephyronline.com Filter Clean Reminder (Standard Baffle Filters fitted): A set of baf fle filters are fitted by the factory . These Baf fle Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the microprocessor will aut[...]
-
Page 24
24 Maintenance BAFFLE FIL TER This must be cleaned once a month using non abrasi- ve detergent s, either by hand or in the dish-washer , which must be set to a low temperature and a short cycle. When washed in a dish-washer , the baf fle filter may discolor slightly , but this does not af fect it s filtering cap acity . T o remove the baf fle filte[...]
-
Page 25
25 www .zephyronline.com Maintenance REPLACING THE MOOD LIGHTING BULB: T o replace mood lighting bulb, remove baf fle filter from hood. T o access lamp area, remove the two threaded knobs that fix the cover . Unscrew mood lighting bulb counter-clockwise and replace with a st andard max. 40W , type T10, 125V -130V medium base bulb.[...]
-
Page 26
26 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal filter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable locking connector is not connecting prop[...]
-
Page 27
27 www .zephyronline.com List of Part s and Accessories Part Description Part# Internal Blower 600 CFM External Blower 1000 CFM Halogen Bulb, 120V 50 W Filter Baffle Z0B0020S EBI-600B CBE-1000 Front Panel 42" SS CPC-0012 Front Panel 42" Brass CPC-01 12 Front Panel 48" SS CPC-0018 Front Panel 48" Brass CPC-01 18 Front Panel 54&qu[...]