American Power Conversion 620 VA инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 14 страниц
- 0.34 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Power Supply
American Power Conversion AP7902 AP7911
26 страниц 1.07 mb -
Power Supply
American Power Conversion MXA002
16 страниц 0.29 mb -
Power Supply
American Power Conversion 3000
60 страниц 1.37 mb -
Power Supply
American Power Conversion AP7620
32 страниц 0.52 mb -
Power Supply
American Power Conversion 400kW1MW
64 страниц 0.88 mb -
Power Supply
American Power Conversion PD80KF6FK1-M
92 страниц 2.72 mb -
Power Supply
American Power Conversion ES 550
2 страниц 0.28 mb -
Power Supply
American Power Conversion AP9222
43 страниц 0.59 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации American Power Conversion 620 VA. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции American Power Conversion 620 VA или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции American Power Conversion 620 VA можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций American Power Conversion 620 VA, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции American Power Conversion 620 VA должна находится:
- информация относительно технических данных устройства American Power Conversion 620 VA
- название производителя и год производства оборудования American Power Conversion 620 VA
- правила обслуживания, настройки и ухода за оборудованием American Power Conversion 620 VA
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск American Power Conversion 620 VA это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок American Power Conversion 620 VA и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта American Power Conversion, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания American Power Conversion 620 VA, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства American Power Conversion 620 VA, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции American Power Conversion 620 VA. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
990 - 1853 C, 10 /2005 User Manual English APC Smart - UPS ® SC 420/620 VA 110/120/230 Vac Tower Uninterruptible Power Supply[...]
-
Страница 2
[...]
-
Страница 3
1 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brow n outs, sags, and surges from reaching your eq uipment. The uninterruptible power supply (UPS) filters small uti l- ity line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line. The UPS prov[...]
-
Страница 4
2 2: S TART UP Connect the Battery Œ • Connect black wire to battery. (Red wire is already connected.) Note: Small sparks at the poin t of battery conne c tion are normal. Ž • Connect Equipment to the UPS Rear Panels 110/120 V: 230 V: § 230 V models: The top off - white outlet pr o- vides surge protection only. Equipment plugged into this 50[...]
-
Страница 5
3 Connect the UPS to the Network (if Applicable) Network Connectors Serial Port Telephone/Network Surge Suppression Ports Use only interface kits a p proved by APC. Use only the supplied cable to connect to the Serial Port. A standard ser ial interface cable is inco m- patible with the UPS. The UPS features optional telephone/network surge suppress[...]
-
Страница 6
4 3: O PERATION Front Display Panel 110/120 V 230 V I NDICATOR D ESCRIPTION On L ine The UPS is supplying utility power to the connected equipment. On Ba t tery Th e UPS is supplying battery power to the connected equipment. Ove r load The connected loads are drawing more than the UPS power rating. Replace Ba t tery The battery must be replaced. F [...]
-
Страница 7
5 4: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE ADJUSTED THROUGH P OWER C HUTE B USINESS E DITION SOFTWARE F UNCTION F ACTORY D E FAULT U SER S E LECTABLE C HOICES D ESCRIPTION Automatic Self - Test Every 14 days (336 hours) Every 7 days (168 hours), Every 14 days (336 hours), On Startup Only, No Self - Test Set t he inte r val at which the U[...]
-
Страница 8
6 N OTE : S ETTINGS ARE ADJUSTED THROUGH P OWER C HUTE B USINESS E DITION SOFTWARE F UNCTION F ACTORY D E FAULT U SER S E LECTABLE C HOICES D ESCRIPTION Low Battery War n ing 2 minutes PowerChute Business Edition sof t ware provides automatic, una t- tended shutdown when approx i- mately 2 mi n utes of battery ope r- ated runtime r e- mains. 2, 5, [...]
-
Страница 9
7 5: S TORAGE AND M AINTENANCE Sto rage Store the UPS covered in a cool, dry location, with the ba t tery fully charged. At - 15 to +30 ° C (+5 to +86 ° F), charge the UPS ba t tery every six months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS ba t tery every three months. Battery Replacement The UPS battery life differs based on usage [...]
-
Страница 10
8 6: T ROUBLESHOOTING , S HIPPING , AND S ERVICE Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.com with co m plex UPS problems, and f or battery runtime charts. P ROBLEM AND / OR P OSSIBLE C AUSE S OLUTION UPS WILL NOT TURN ON UPS not connected to utility power supply. Check that the power cord from th[...]
-
Страница 11
9 P ROBLEM AND / OR P OSSIBLE C AUSE S OLUTION THE OVERLOAD LED IS ILLUMINATED AND THE UPS EMITS A SU S TAINED ALARM TONE The UPS is overloaded. The connected equipment is dra w- ing more VA than the UPS can sustain. The connected eq uipment exceeds the specified “maximum load.” The alarm remains on until the overload is removed. Disconnect non[...]
-
Страница 12
10 Shipping and Service Prepare the UPS for shipping: Shutdown and disconnect any equipment attach ed to the UPS. Shut down the UPS, and di s connect the UPS from the utility power outlet. Disconnect the battery. If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in Troubleshooting to el[...]
-
Страница 13
11 7: R EGULATORY AND W ARRANTY I NFORMATION 110/120 V models This equipment has been tested and found to comply with the limits for a Class A digital device, pu r- suant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial enviro n ment. [...]
-
Страница 14
12 Limited Warranty American Power Conversio n (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole o p tion, any such defective prod ucts. To obtain service under warranty you mus[...]