American Power Conversion PM3 инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 24 страниц
- 1.12 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Power Supply
American Power Conversion 250
36 страниц 0.26 mb -
Power Supply
American Power Conversion 100VAC
27 страниц 0.73 mb -
Power Supply
American Power Conversion VA 1000
16 страниц 0.42 mb -
Power Supply
American Power Conversion 400V
100 страниц 2.13 mb -
Power Supply
American Power Conversion 1000, 1100, 1400
2 страниц 0.18 mb -
Power Supply
American Power Conversion RS 800
2 страниц 0.44 mb -
Power Supply
American Power Conversion 250 VA
16 страниц 0.42 mb -
Power Supply
American Power Conversion MX28B2400
70 страниц 3.39 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации American Power Conversion PM3. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции American Power Conversion PM3 или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции American Power Conversion PM3 можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций American Power Conversion PM3, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции American Power Conversion PM3 должна находится:
- информация относительно технических данных устройства American Power Conversion PM3
- название производителя и год производства оборудования American Power Conversion PM3
- правила обслуживания, настройки и ухода за оборудованием American Power Conversion PM3
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск American Power Conversion PM3 это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок American Power Conversion PM3 и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта American Power Conversion, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания American Power Conversion PM3, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства American Power Conversion PM3, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции American Power Conversion PM3. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
Sur geArrest ® PM Series PM3, PM4, and PM4Y Series Modular Surge Protective Device (SPD) User ’ s Manual American Power Conversion Corporation 132 Fairgrounds Road P .O. Box 278 W est Kingston, Rhode Island 02892 USA APC0212040A www .apc.com[...]
-
Страница 2
[...]
-
Страница 3
INTRODUCTION ......................................................................................................................................... 1 Installation .............................................................................................................................................. 1 T esting ..............................[...]
-
Страница 4
Contents Sur geArrest ® PM Series FIGURES Figure 1 - T ypical Parallel Connections ........................................................................................ ........ 4 Figure 2 - Basic PM3 and PM4 Configuration with Disconnect Switch Option ................................ 5 Figure 3 - Basic PM3 and PM4 Configuration and W iring Dia[...]
-
Страница 5
INTRODUCTION Thank you for choosing the APC SurgeArrest PM3, PM4, or PM4Y Series Sur ge Protective Device. The APC modular Sur ge Protective Device (SPD) is a high quality , high ener gy surge attenuation system that has been designed to protect sensitive equipment from damaging transient voltage surges. Proper installation is imperative to maximiz[...]
-
Страница 6
Unp acking and Preliminary Inspection • Inspect the entire shipping container for damage or signs of mishandling before unpacking the unit. • Remove the cardboard packing and further inspect the unit for any obvious shipping damages. • If damage found is a result of shipping or handling, immediately file a claim with the shipping company and [...]
-
Страница 7
Page 3 Service Clearance In addition to national and local code requirements, 36 inches of service clearance is needed at the front of the SPD. Equipment Performance T o obtain the maximum system performance, the unit must be located as close to the circuit to be protected as possible, minimizing the interconnecting wire length. For every foot of w[...]
-
Страница 8
Figure 1. T ypical Parallel Connections NOTE: Safety Ground required for ALL units. Page 4 T able 2: V oltage Rating and Service T ype (by Model) T erminals T erminals have been provided inside the APC modular SPD units for the line (phase), neutral, and equipment safety ground connections. T erminal wire size for all models is #8 A WG - #1 A WG . [...]
-
Страница 9
Wiring Size & Inst allation T orque W ith a parallel connection, the size of the wiring to the SPD is independent of the ampere rating of the circuit to be protected. The recommended wire size is based on the unit’ s transient surge current capabilities. #6 A WG is the recommended wire size for phase, neutral and ground conductors. Disconnect[...]
-
Страница 10
Page 6 PM SERIES INST ALLA TION INSTRUCTIONS (T ypical Unit - Three Phase WYE, 4 Wire, plus Ground) This section provides basic installation instructions for the PM Series SPD. Per UL 1449 Paragraph 1.4, SPD’ s “are intended for installation on the load side of the main overcurrent protection”. Locate the SPD as close as possible to the circu[...]
-
Страница 11
Page 7 Figur e 3: Basic PM3 and PM4 Configuration and Wiring Diagram (3-Phase WYE, 4-W ire, plus Ground)[...]
-
Страница 12
Page 8 5/16” Mounting Hole (4 places) Phase A Phase B Connectors Phase C Connector Ground Conductor Not to exact scale. Door removed for clarity Fuse (9 places) Mounting Flange (4 places) Surge Module with LED (9 places) Disconnect Figur e 4. Basic PM4Y Configuration and W iring Diagram (3-Phase WYE, 4-W ire, plus Gr ound) Neutral Conductor[...]
-
Страница 13
Operation and Features SPD’ s do not require a great deal of operator intervention after installation. NOTE: The PM Series has a green LED for each phase which extinguishes when the module is no longer providing protec- tion (fault condition). All of the PM Series of SPDs contain a diagnostic circuit which monitors the suppressor status continuou[...]
-
Страница 14
Page 10 Surge Counter Option In units so equipped, the surge counter option provides a means to total the number of transient voltage sur ges encountered since the counter was last reset. The sur ge counter circuitry includes a “supercap”. This will provide power up to four days to retain memory should a power outage occur . NOTE: There is a 10[...]
-
Страница 15
Periodic Inspection and Cleaning Inspection of the SPD should be performed periodically to maintain reliable system performance and continued transient voltage sur ge protection. While it is difficult to establish a preventive maintenance schedule because conditions vary from location to location, inspections for trouble utilizing the on-line diagn[...]
-
Страница 16
Figure 6: T roubleshooting Flowchart Page 12[...]
-
Страница 17
• MAINTENANCE OF THIS SURGE PROTECTIVE DEVICE SHOULD BE PERFORMED BY QUALIFIED ELECTRICAL PERSONNEL ONL Y . • DURING NORMAL OPERA TION, HAZARDOUS VOL T AGES ARE PRESENT INSIDE THE UNIT . • WHEN SERVICING THIS UNIT , BE SURE T O FOLLOW ALL ELECTRICAL SAFETY PRECAUTIONS. • ALL POWER SOURCES T O THIS UNIT SHOULD BE LOCKED OFF BEFORE SERVICING [...]
-
Страница 18
Diagnostic Board Removal & Replacement Instructions T o remove the Diagnostic Board, refer to Figure 8 and proceed as follows: 1. Disconnect power to the SPD. 2 . Remove the board from the standof fs. 3. Remove the connectors one at a time from the existing board and insert them into the appropriate connector on the replacement board. 4. Instal[...]
-
Страница 19
Surge Module Removal & Replacement Instructions Sur ge modules within the SPD may become damaged and require replacement. T o remove and replace a surge module, refer to Figure 9 and proceed as follows: 1. Disconnect power to the SPD. 2. Open the door on the unit by loosening the two screws that secure the door latches in place. Slide the top l[...]
-
Страница 20
T able 4: Replacement Parts List Replacement Part s Listing APC offers the items listed in T able 4 as field replaceable items. Page 16 l e d o M C P A r e b m u N m e t s y S e g a t l o Vn o i t p i r c s e D: h t i W s k r o W t r a P 4 M E Y W e s a h P - 3 , V 0 2 1 / 8 0 2 e s a h P t i l p S , V 0 2 1 / 0 4 2 e l u d o M e s a h P A k 0 6 1s[...]
-
Страница 21
Page 17 LIMITED W ARRANTY APC warrants it’ s AC Panel protection products against defective workmanship and materials for 5 years from the date of original purchase. The panel protection device must be installed by a qualified and licensed electrician in order to qualify fo r warranty protection. Liability is limited to the replacement of the def[...]
-
Страница 22
[...]
-
Страница 23
[...]
-
Страница 24
American Power Conversion Corporation 132 Fairgrounds Road P .O. Box 278 W est Kingston, Rhode Island 02892 USA www .apc.com[...]