American Power Conversion 5000 VA manual
- Consulta online o descarga el manual de instrucciones
- 23 páginas
- 0.46 mb
Ir a la página of
manuales de instrucciones parecidos
-
Power Supply
American Power Conversion 10-40kW 208/480V
31 páginas 1.1 mb -
Power Supply
American Power Conversion 2200
60 páginas 0.82 mb -
Power Supply
American Power Conversion BH500NET
4 páginas 5.82 mb -
Power Supply
American Power Conversion AP7608
24 páginas 0.58 mb -
Power Supply
American Power Conversion DP300E series
12 páginas 1.27 mb -
Power Supply
American Power Conversion 350/500
2 páginas 0.29 mb -
Power Supply
American Power Conversion SUDP6000I
24 páginas 0.81 mb -
Power Supply
American Power Conversion AP9215
20 páginas 0.29 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones American Power Conversion 5000 VA. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica American Power Conversion 5000 VA o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual American Power Conversion 5000 VA se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales American Power Conversion 5000 VA, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones American Power Conversion 5000 VA debe contener:
- información acerca de las especificaciones técnicas del dispositivo American Power Conversion 5000 VA
- nombre de fabricante y año de fabricación del dispositivo American Power Conversion 5000 VA
- condiciones de uso, configuración y mantenimiento del dispositivo American Power Conversion 5000 VA
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de American Power Conversion 5000 VA no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de American Power Conversion 5000 VA y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico American Power Conversion en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de American Power Conversion 5000 VA, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo American Power Conversion 5000 VA, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual American Power Conversion 5000 VA. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
990-2690 0 2/2006 User Manual English APC Smart-UPS ® RT 3000/500 0 VA 200-240 VAC Tower/Ra ck Mount 3U Uninterrupti ble Power Supply[...]
-
Página 2
[...]
-
Página 3
1 Introduction The APC Sm art-UPS® RT is a h igh-perf ormance, unint erruptible pow er supply (UPS) that prov ides protection for electron ic equipment from utilit y po wer blackou ts, brownouts, sags and surges. The UPS filters small utilit y line fluctuations and isolates electronic equip ment from large disturbances by in ternally disconn ectin[...]
-
Página 4
2 Wiring and Connecting the UPS 5000 VA XLI MO DELS O NLY : H ARDWIRING I NSTRUCTIONS • Wiring must be performe d by a qualif ied electrician. • Install a high magnetic 30/32 A utility circuit br eaker. • Adhere to all national and local electrical codes. • Use #10 A WG gauge (5 mm 2 ) w ir e. 1. Switch the utility circuit breaker OFF. 2. R[...]
-
Página 5
3 C ONNECTING THE B ATTE RY MODULES AND A TTACHING THE F RONT B EZEL [...]
-
Página 6
4 B ASIC C ONNE CTORS serial com The serial connector is to be u sed for interf acing with APC Po w erChute software and terminal emulation software. Use only cables appro ved by APC. Any other interface cable will be incompatible with the UPS connector. normal bypass Manual bypass enables t he user to manually put connected eq uipment into bypass [...]
-
Página 7
5 C ONNECTING E QUIPME NT AND P OWER TO TH E UPS 1. Connect equ ipment to the UPS (cables not included for XLJ/XLT/XLTW m odels). 2. Avoid using exte nsion cords. • 3000 VA XLJ/ XLT/XLI/XL TW and 5000 VA XLJ/ XLT/XLTW models : Using a pow er cord, plug the UPS into a two- pole, thr ee-wire, grounded receptacle only . • 5000 VA XLJ model s: To d[...]
-
Página 8
6 O PERA TION Load S MART -U PS RT F RONT D ISPLAY Battery Charge Indicator Description Online The Online LED il luminates when th e UPS is drawing utility powe r and performing double con version to supply power to con nected equipment. On Battery The UPS is supplying battery po w er to the connected equi pment. Bypass The Bypass LED ill uminates [...]
-
Página 9
7 Feature Function Cold Start When there is no utility po wer and the UPS is off, press and hold the button to power up th e UPS and connected equipment. The UPS will emit two beeps. During the second beep, release the bu tton. Self-Test Automatic: The UPS performs a s elf-test automatically when turned on, and ev ery two weeks thereafter (by defau[...]
-
Página 10
8 U SER C ONFIGU RA BLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OW E R C HUTE SOFTW ARE , OPTIONAL S MA RT S LO T ACCESSO RY CARDS , OR T ER MI NAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRI PTION Automa tic Self-Tes t On start-up a nd eve ry 14 day s, thereafter On start-u p and every 7 days thereafter On s[...]
-
Página 11
9 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OW E R C HUTE SOFTW ARE , OPTIONAL S MA RT S LO T ACCESSO RY CARDS , OR T ER MI NAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRI PTION Low Bypass Point 160 VA C Output Volta ge Settin g 200 VAC: 160 - 185 VA C 208 VAC: 160 - 190 VA C 220 VAC: 160 - 195 VA C 230 VAC : 160 - 20[...]
-
Página 12
10 C ONNECTING THE EPO (E MERGENCY P OWER O FF ) O PTION The output pow er can be disabled in an emergen cy b y clos ing a switch connected to the EPO. Adhere to National and local electrical codes wh en wiring the EPO. The EPO switch is intern ally po wered by t he UPS for us e with non-po w ered switch circuit breakers. The EPO circuit is conside[...]
-
Página 13
11 T ERMI NAL M OD E TO C ONFIGURE UPS P ARAMETE RS 3000 VA m odels: Terminal Mode is a menu driven interface that enables configuration of the UPS by users not wi shing to use P o werChut e ® soft ware or an o ptio nal Ne twork M ana geme nt Car d. Connect the serial cable to th e serial co m con nector on the back of the UPS. If Pow erChute sof [...]
-
Página 14
12 5000 VA m odels: Terminal Mode is a menu driven interface that enables configuration of the UPS by users not using Pow erChute ® software or the ins talled Network Manageme nt Card interf aces. Connect the serial cable to the serial port on the back of th e UP S. If Pow erChute sof tware is not in stalled do not perform steps 1 and 5. 1. For W [...]
-
Página 15
13 • Press 2 and ENTE R to change the Battery Settings. • Type in the number of external battery packs (four batt ery modules per pack ), and press E NTE R. (Num ber of packs: 1 = 1 S URT192XLBP, 2 = 2 SURT192XL BP etc.) • Press 3 and ENTER to accept the changes. • Press ESC multiple times (5) to return to the main menu. • Press 4 an d EN[...]
-
Página 16
14 M AIN TE N AN C E AN D T RA NSPOR T Replacing the Battery Module This UPS has an easy to replace, h ot-swappable battery module. Replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and connected equipm ent on during the procedure. See y our dealer or contact APC at th e Web site, www.apc.com for infor m atio [...]
-
Página 17
15 R EPLACING B ATTERY MODULES X Y Z [ ] ^ _ Disconnecting the Battery for Transport Alway s DISCONNECT THE B ATTERY(s) befo re ship ping in compliance with U.S. Departm ent of Transportation (DOT) and I ATA regulations. The battery(s) m ay remain in the UPS. 1. Shut down an d disconnect any equipment attach ed to the UPS. 2. Shut down and di[...]
-
Página 18
16 T ROUBLESHOOTING , S ER VICE , AN D W A RRA NTY I N FORMA T ION Use the table below to solve minor installation and op eration problems. Refer to the AP C Web site, www.apc.com for assistan ce with complex UPS problems. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batt ery not conn ected p rop erly. Check t hat the b atter y con[...]
-
Página 19
17 P ROBLEM AND P OSSI BLE C AUSE S OLUTION BYPASS LED ILLUM INA TES The bypass swi tch ha s been turne d on m anually or throu gh an acce ssory . If bypa ss is t he chosen mode of oper ation, ignore t he illum inated L ED. If bypa ss is not the chos en mode of op era tion move t he bypas s swit ch on the back o f the UPS , to th e normal posit ion[...]
-
Página 20
18 Service If the UPS requires service do not return it to the dealer. Follow these s teps: 1. Revi e w the problems discussed in th e Troubleshoot ing section of this manual to eliminate common problem s. 2. If th e problem persis ts, contact APC Customer Support t hrough the APC Web site, www.apc.com . • Note the m odel number of the UPS, the s[...]
-
Página 21
19 R EGULA TOR Y Regulatory Agenc y Approvals a nd Radio F reque ncy Warnings 200, 208, 22 0, 230, 240 V MODELS This e quipm ent has bee n teste d and f ound to com ply with the limits f or a Class A digi tal de vice, p ursua nt to part 15 of t he FCC Ru les. Th ese limi ts are des igned t o provid e reason able p rotect ion a gainst ha rmfu l inte[...]
-
Página 22
20 Declaration of Conformity[...]
-
Página 23
21 A PC Worldwi de C ustomer Support Custom er support for th is or any other APC produ ct is available at n o charge in any of the following wa ys: • Refer to th e APC Web site to access documents in the APC Knowledg e Base and to submit customer su pport requests . • www.apc.com (Corporate H eadquarters) Connect to localized A PC Web sites fo[...]