Minuteman UPS Enterprise Plus Series manual
- Consulta online o descarga el manual de instrucciones
- 32 páginas
- 1.79 mb
Ir a la página of
manuales de instrucciones parecidos
-
Power Supply
Minuteman UPS AT800, GS800 (800VA)
14 páginas 0.18 mb -
Power Supply
Minuteman UPS MCP 3000
24 páginas 0.86 mb -
Power Supply
Minuteman UPS PRO-E
24 páginas 0.43 mb -
Power Supply
Minuteman UPS AT2300, GS2300 (2300VA)
14 páginas 0.18 mb -
Power Supply
Minuteman UPS CPE 2000
17 páginas 0.64 mb -
Power Supply
Minuteman UPS MCP 10001
20 páginas 0.22 mb -
Power Supply
Minuteman UPS PN-34000247
2 páginas 0.26 mb -
Power Supply
Minuteman UPS ALLIANCE
15 páginas 0.09 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Minuteman UPS Enterprise Plus Series. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Minuteman UPS Enterprise Plus Series o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Minuteman UPS Enterprise Plus Series se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Minuteman UPS Enterprise Plus Series, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Minuteman UPS Enterprise Plus Series debe contener:
- información acerca de las especificaciones técnicas del dispositivo Minuteman UPS Enterprise Plus Series
- nombre de fabricante y año de fabricación del dispositivo Minuteman UPS Enterprise Plus Series
- condiciones de uso, configuración y mantenimiento del dispositivo Minuteman UPS Enterprise Plus Series
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Minuteman UPS Enterprise Plus Series no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Minuteman UPS Enterprise Plus Series y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Minuteman UPS en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Minuteman UPS Enterprise Plus Series, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Minuteman UPS Enterprise Plus Series, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Minuteman UPS Enterprise Plus Series. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
User's Manual Enterprise Plus Series UPS[...]
-
Página 2
1 © Copyright 2006 1 . Introduction 2 2 . Controls and Indicators 6 3. Installation 9 4. Operation 15 5 . T roubleshooting 18 6 . Replacing the Battery 19 7 . Obtaining Service 22 8 . Specifications 23 9 . Configurable Parameters & Settings 25 10. Limited Product W arranty 26 A 1. Declaration of Conformity 28 English[...]
-
Página 3
2 IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS ! English Thank you for purchasing this power protection product. It has been designed and manufactured to provide many years of trouble free service. Please read this manual before installing your Enterprise Plus Series UPS, models E750RM2U, E1000RM2U, E1500RM2U, E1500RMT2U, E2000RM2U, E300[...]
-
Página 4
3 W ARNING: Risk of Electrical Shock. Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected. CAUTION! T o de-energize the outputs of the UPS: 1. If the UPS is on press and release the On/Off/T est button. NOTE: For the 208V models; turn the input circuit breaker to the off posi- tion.[...]
-
Página 5
4 English After removing your UPS from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored. The packing materials that your UPS was shipped in are carefully designed to minim[...]
-
Página 6
5 English Life Support Policy As a general policy , we do not recommend the use of any of our product s in life support applications where failure or malfunction of the product can be reason- ably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. We do not recommend the use of any of our pr[...]
-
Página 7
6 English The AC normal (green) LED illuminates in a steady state when the UPS is on and operating in the AC normal mode. The AC normal LED will extinguish when operating in the Battery mode. The On-Battery (green) LED illuminates in a steady state when the UPS is operating in the Battery mode. The On-Battery LED will extinguish when operating in t[...]
-
Página 8
7 English The Load Level Bar Graph (AC mode only) operates as follows: LED #10: >10% load (green/red/yellow) LED will be green and illu- minated when there is at least 10% of the rated capacity . LED #30: >30% load (green/yellow) LED will be green and illumi- nated when there is at least 30% of the rated capacity . LED #50: >50% load (gree[...]
-
Página 9
8 English REAR P ANEL 1. The RS232 Communications Interface Port is for UPS monitoring and control. 2. The USB Communications Interface Port is for UPS monitoring and control. 3. The RJ1 1 REPO (Remote Emergency Power Of f) Port is for UPS control. 4. The option slot is for option cards. 5. The External Battery Connector is for connecting External [...]
-
Página 10
9 English INST ALLA TION PLACEMENT This UPS series is intended to be install in a temperature controlled environ- ment that is free of conductive contaminants. Select a location which will provide good air circulation for the UPS at all times. A void locations near heat- ing devices, water or excessive humidity , or where the UPS is exposed to dire[...]
-
Página 11
10 English CONNECTING THE BA TTERIES (QUALIFIED SERVICE PERSONNEL ONL Y) Please read all of the W ARNINGS and CAUTIONS before attempting to con- nect the batteries. 1. Remove the UPS from the shipping box and set on the floor or a bench top. 2. Remove the front panel retaining screws. 3. Lay the front panel on top of the UPS. 4. V erify proper pola[...]
-
Página 12
11 English RACKMOUNT CONFIGURA TION This UPS comes with mounting brackets for the standard 19" (46.5cm) rack. The mounting brackets to fit a 23" (59.2cm) standard rack are also available. The screws for mounting the UPS to the rack are not included (screw size varies with rack size). 1. Locate the mounting bracket screw holes on the side [...]
-
Página 13
12 English T OWER CONFIGURA TION The tower configuration allows the user to install the UPS in the up-right position next to the tower computer . The tower brackets are provided with the UPS. W ARN- ING: Use two or more people when installing the UPS. Use CAUTION, the UPS is extremely heavy . 1. Once the location of the UPS has been determined, pla[...]
-
Página 14
13 English W ALLMOUNT CONFIGURA TION The wallmount configuration allows the user to mount the UPS on the wall. There is a wallmount bracket kit available for the UPS. The kit includes two wall mounting brackets, ten ret aining screws, and the wallmount template. W ARNING: Use two or more people when installing the UPS. Use CAUTION, the UPS is extre[...]
-
Página 15
14 English CHARGING THE BA TTER Y The UPS will charge the internal batteries whenever the UPS is connected to an AC source a nd there is an acceptable AC voltage present. NOTE: The input circuit breaker MUST be in the on position for the 208V models. It is recom- mended that the UPS's batteries be charged for a minimum of 4 hours before use. T[...]
-
Página 16
15 English SYSTEM OVERVIEW This Line-Interactive UPS protects computers, internetworking, and telecom- munications equipment from blackouts, brownouts, overvoltages, and surges. The A VR function continuously corrects the voltages, in-between the brownout and overvoltage transfer points (80 - 164V AC/150 - 271V AC), to a safe usable level. When the[...]
-
Página 17
16 English COMMUNICA TIONS PORTS (RS232 and USB) The RS232 communication port is a standard DB9 female with both RS232 and simulated contact closure capability . The UPS will poll the port and activate the port for RS232 or contact closure in accordance with the type of cable it finds connected to the port. T o change the port configuration require[...]
-
Página 18
17 English WEAK/BAD BA TTER Y The UPS automatically tests the battery’s condition and will illuminate the Weak/ Bad Battery LED and sound the alarm. This alarm will be repeated until the batteries pass a self test. If the battery is weak, bad or disconnected, the Weak/Bad Battery LED will illuminate and the alarm will beep three times every five-[...]
-
Página 19
18 English Possible Cause Symptom What T o Do Press and release the On/Off/ T est button to start UPS On/Off/T est button not pushed UPS will not turn on Reset circuit breaker by pressing the plunger back in. If the AC circuit breaker trips after UPS starts up, reduce the load on the UPS UPS operates in battery mode only , even though there is norm[...]
-
Página 20
19 English REPLACING THE BA TTER Y W ARNING! This Uninterruptible Power Supply contains potentially hazardous voltages. Do not attempt to disassemble the UPS beyond the battery replacement procedure. This UPS contains no user serviceable parts. Repairs and Battery replacement must be performed by QUALIFIED SERVICE PERSONNEL ONL Y . Do not open or m[...]
-
Página 21
20 English BA TTER Y REPLACEMENT PROCEDURE PLEASE READ THE CAUTIONS AND W ARNINGS BEFORE A TTEMPTING TO REPLACE THE BA TTERIES Hot-swappable batteries mean that the batteries can be replaced without powering down the whole UPS system. NOTE: If there is a power interruption while replacing the hot-swappable batter- ies, with the UPS on, the load wil[...]
-
Página 22
21 English 8. Remove the two retaining screws for the battery ret aining bracket. (FIG . 3) 9. Remove the battery retaining bracket. (FIG . 3) 10. Disconnect the Battery connectors (red and black). (FIG . 4) 1 1. Grasp the battery pull tab and gently pull the battery module out of the UPS and set on the floor . (FIG . 4) NOTE: Use Caution, the batt[...]
-
Página 23
22 English IF THE UPS REQUIRES SERVICE 1. Use the TROUBLESHOOTING section to eliminate obvious causes. 2. V erify there are no circuit breakers tripped. A tripped circuit breaker is the most common problem. 3. Call your dealer for assistance. If you cannot reach your dealer , or if they cannot resolve the problem call or fax the T echnical Support [...]
-
Página 24
23 English Default: 120V AC (208V AC), User selectable: 127V AC (240V AC) 750V A 600W 1500V A 1200W 1000V A 800W Protection W aveform T ype Over-Current, Short-Circuit Protected and Latching Shutdown Sine Wave Frequency 50/60Hz, +/-0.1Hz (unless synchronized to utility) Nominal V oltage Maximum Power Capacity 2-6 ms T ypical >93% (Full Load) Res[...]
-
Página 25
24 English BA TTERY SYSTEM T ypical Recharge T ime T ypical Battery Life Battery: Quantity/Rating 3-5 years, depending on discharge cycles and ambient temp 3-12V7.2Ah 3-12V8.5Ah 8-hours from total discharge 6-12V7.2Ah Battery T ype Sealed, Non-S pillable, Maintenance Free, V alue Regulated Lead Acid System V olt age 36VDC 36VDC 72VDC Runtime: Full [...]
-
Página 26
25 English (These items may require optional software or hardware) Function Factory Default Description User Choices Set inverter output voltage Shut- down T ype Set audible alarm state Enable/ Disable auto restart Battery life in days Battery install date UPS ID Enterprise Plus Series Date of manufacture 1826 Enabled Enabled Entire UPS 120V AC (20[...]
-
Página 27
26 English Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of three years from the date of purchase. For equip- ment sites within the United S tates and Canada, this warranty covers repair or replacement of defective equipm[...]
-
Página 28
27 English EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL P ARA SYSTEMS BE LIABLE FOR DIRECT , INDIRECT , SPECIAL, INCIDENT AL, OR CONSEQUEN- TIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT , EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. S pecifically , Para Sys- tems is not liable for any costs, such as lost profits or revenue, loss of equip-[...]
-
Página 29
28 English A1. DECLARA TION OF CONFORMITY Application of Council Directive(s): 89/336/EEC, 73/23/EEC S tandard(s) to which Conformity is declared: Manufacturer’s Name: Para Systems, Inc. (MINUTEMAN UPS) Manufacturer ’s Address: 1455 LeMay Drive Carrollton, T exas 75007 USA T ype of Equipment: Uninterruptible Power Supplies (UPS) Model No: E750R[...]
-
Página 30
29 Notes: English[...]
-
Página 31
30 English Notes:[...]
-
Página 32
Para Systems, Inc. 1455 Lemay Dr . Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-901 1 Internet: minutemanups.com UPS Sizing: sizemyups.com PN - 34000271[...]