THOMSON Wireless Business DSL Routers SpeedTouchTM620 manual
- Consulta online o descarga el manual de instrucciones
- 216 páginas
- 3.23 mb
Ir a la página of
manuales de instrucciones parecidos
-
Network Router
THOMSON 570
48 páginas 0.8 mb -
Network Router
THOMSON THG540
36 páginas 1.72 mb -
Network Router
THOMSON 605
208 páginas 3.82 mb -
Network Router
THOMSON 585 v7
66 páginas 2.12 mb -
Network Router
THOMSON Network Router
72 páginas 1.47 mb -
Network Router
THOMSON SpeedTouch 536
104 páginas 2.43 mb -
Network Router
THOMSON 210i
79 páginas 6.28 mb -
Network Router
THOMSON Wireless Business DSL Routers SpeedTouchTM620
216 páginas 3.23 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones THOMSON Wireless Business DSL Routers SpeedTouchTM620. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica THOMSON Wireless Business DSL Routers SpeedTouchTM620 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual THOMSON Wireless Business DSL Routers SpeedTouchTM620 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales THOMSON Wireless Business DSL Routers SpeedTouchTM620, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones THOMSON Wireless Business DSL Routers SpeedTouchTM620 debe contener:
- información acerca de las especificaciones técnicas del dispositivo THOMSON Wireless Business DSL Routers SpeedTouchTM620
- nombre de fabricante y año de fabricación del dispositivo THOMSON Wireless Business DSL Routers SpeedTouchTM620
- condiciones de uso, configuración y mantenimiento del dispositivo THOMSON Wireless Business DSL Routers SpeedTouchTM620
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de THOMSON Wireless Business DSL Routers SpeedTouchTM620 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de THOMSON Wireless Business DSL Routers SpeedTouchTM620 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico THOMSON en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de THOMSON Wireless Business DSL Routers SpeedTouchTM620, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo THOMSON Wireless Business DSL Routers SpeedTouchTM620, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual THOMSON Wireless Business DSL Routers SpeedTouchTM620. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
SpeedT ouch™620 Wireless Business DSL Routers Operator’s Guide Power Ethernet W LA N Plug-in ISD N Internet DSL[...]
-
Página 2
[...]
-
Página 3
SpeedTouch™ 620 Operator’s Guide[...]
-
Página 4
Copyright Copyright ©1999-2006 THOMSON. All rights reserved. Distribution and co pying of this do cument, use and c ommunication of i ts contents is no t permitted without written authorizatio n from THOMSON. The con tent of this document is furnished for informati onal use only , may be subject to chang e without notice, and should not be con str[...]
-
Página 5
Contents E-DOC-CTC-20051 017-0155 v1.0 i Contents 1 Introduction ................. .................................................. 3 2 SpeedTouch™ Command Li ne Interface .................... 5 2.1 About the CLI Interface ....... ............ .......................... ............ ......... 5 2.2 CLI Ac cess via T elnet or Se rial Console . .[...]
-
Página 6
Contents E-DOC-CTC-2005 1017-0155 v1.0 ii 4.4 SpeedTouch™ Service Templates .......... .......... ........... .......... ....... 40 4.5 SpeedTouch™ System Languages Mana gement ........... ........ ....... 41 5 SpeedTouch™ Software Modules ............................. 45 5.1 Software Activation Key Management .. .......... ........... ......[...]
-
Página 7
Contents E-DOC-CTC-20051 017-0155 v1.0 iii 8 SpeedTouch™ Remote Access .......... ........................ 79 8.1 Remote Web Interface Access ... ............. ................. ............... ..... 81 8.2 Secure Rem ote Web Interface Acce ss ......... ............. ............ ....... 84 8.3 Remote Telnet Access.................. .............[...]
-
Página 8
Contents E-DOC-CTC-2005 1017-0155 v1.0 iv 10 SpeedTouch™ Monito ring ................ ...................... 133 10.1 An Introduction to SNMP .... ............ ............. ........... ................... 134 10.1.1 Basic Concepts ........................... ................. ................. ................. ................. ............ .. [...]
-
Página 9
Contents E-DOC-CTC-20051 017-0155 v1.0 v 11.3 Command Line Interface Diagnostics ...... ............. ............ ......... 179 11.3.1 About CLI Diagnostics ............... .............. .............. ................. .............. .............. ......... 180 11.3.2 Lower Layer Dia gnostics ......... ..........................................[...]
-
Página 10
Contents E-DOC-CTC-2005 1017-0155 v1.0 vi[...]
-
Página 11
About this Operator’s Guide E-DOC-CTC-20051 017-0155 v1.0 1 About this Operator’s Guide Used Symbols Terminology Generally , the SpeedT ouch™620 will be referred to as S peedT ouch™ in this Operator’ s G uide. Typographical Conventions When we display intera ctive input and output we’l l show our typed input in a bold font and the compu[...]
-
Página 12
About this Operator’s Guide E-DOC-CTC-2005 1017-0155 v1.0 2[...]
-
Página 13
Chapter 1 Introduction E-DOC-CTC-20051 017-0155 v1.0 3 1I n t r o d u c t i o n Overview Being a key component of your business network, a good operatio n of the SpeedT ouch™ is esse ntial to gain maxim um performance of you r DSL connectivity . Continuous management and diagnosis of the SpeedT ouch™ should be performed to ensure a faultless op[...]
-
Página 14
Chapter 1 Introduction E-DOC-CTC-2005 1017-0155 v1.0 4[...]
-
Página 15
Chapter 2 SpeedTouch™ Command Line Interface E-DOC-CTC-20051 017-0155 v1.0 5 2 SpeedTouch™ Command Line Interface 2.1 About the CLI Interface CLI access Y ou can access the Command Line Interface via: The SpeedT ouch™ CLI W eb Interface A T e lnet session The serial Console interface. CLI web page access requirements T o access th[...]
-
Página 16
Chapter 2 SpeedTouch™ Comma nd Line Interfa ce E-DOC-CTC-2005 1017-0155 v1.0 6 2.2 CLI Access via Telnet or Serial Console Access via a Telnet session or serial console As soon a session to the CLI is opened , a banner pops up, foll owed by the CLI prompt: If the SpeedT ouch™ is protected by a system password, authentication will be required be[...]
-
Página 17
Chapter 2 SpeedTouch™ Command Line Interface E-DOC-CTC-20051 017-0155 v1.0 7 2.3 Basic Navigation Command group navigation From the top level, you can change to a command group by executin g the name of the desired command group (for example ty pe the name of the command group and press ENTER). T o obtain a list of all avail able command groups, [...]
-
Página 18
Chapter 2 SpeedTouch™ Comma nd Line Interfa ce E-DOC-CTC-2005 1017-0155 v1.0 8 Help Y ou can use help or ? from any level to list all available comman ds and co mmand groups for that level . Below an example is provid ed of executing help from the firewall command gro up selection: Entering help followed by a specific comm and, for example :help [...]
-
Página 19
Chapter 2 SpeedTouch™ Command Line Interface E-DOC-CTC-20051 017-0155 v1.0 9 History of Commands The CLI allows you to re-use commands you have used before during a CLI session. T o scroll through the previo usly used CLI commands use UP ARROW and DOWN ARROW . T o execute a re-used command, press ENTER.[...]
-
Página 20
Chapter 2 SpeedTouch™ Comma nd Line Interfa ce E-DOC-CTC-2005 1017-0155 v1.0 10 2.4 Command Line Interface Commands Executing Commands from the Top Level All CLI commands are co mmands that oper ate on, or configure, the SpeedT ouch™ settings. Y ou can use these comman ds from top le vel, preceded by the name of the command group from wh ich th[...]
-
Página 21
Chapter 2 SpeedTouch™ Command Line Interface E-DOC-CTC-20051 017-0155 v1.0 11 Executing Commands from the Command Group Y ou can also enter the command s from the command gr oup itself, using the reduced form of the command (for example list at the firewa ll command group selection): “!” in a command means NOT , for example the [ ! ] paramete[...]
-
Página 22
Chapter 2 SpeedTouch™ Comma nd Line Interfa ce E-DOC-CTC-2005 1017-0155 v1.0 12 Saving the configuration After configuring the SpeedT ouch™ via the CLI, it is advised to save your configuratio n. Y ou can save the complete SpeedT ouch™ configuration to persistent memory by executing the saveall command . The saveall command can be entered fro[...]
-
Página 23
Chapter 2 SpeedTouch™ Command Line Interface E-DOC-CTC-20051 017-0155 v1.0 13 2.5 Menu-driven CLI Navigation Introduction T o improve the user -friendliness of the Sp eedT ouch™ CL I, the CLI features a menu- driven in terface. Entering the CLI menu T o enter the menu-dri ven inter face, simply enter the command menu from the CLI prompt: The se[...]
-
Página 24
Chapter 2 SpeedTouch™ Comma nd Line Interfa ce E-DOC-CTC-2005 1017-0155 v1.0 14[...]
-
Página 25
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-20051 017-0155 v1.0 15 3 SpeedTouch™ System Software 3.1 About the System Software Upgrade system software For new system software pa ckages, you can visit the SpeedT ouch™ support pages at: http://www .speedtouch.com System software packages and security All SpeedT ouch™ system software packa[...]
-
Página 26
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-2005 1017-0155 v1.0 16 3.2 System Software Management via FTP FTP access For more information on the SpeedT ouc h™ file system and how to access it via F TP , see “7 The SpeedT ouch™ File System” on page 75 . SpeedTouch™ system software locations The SpeedT ouch™ file system consists of [...]
-
Página 27
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-20051 017-0155 v1.0 17 3.2.1 Backup System Software via FTP Introduction For backup reasons, yo u can transfer system software files from both SpeedT ouch™’ s ‘/active’ and ‘/dl’ su bdirectories to your local disk. Backup procedure T o transfer system software files from the SpeedT ouch?[...]
-
Página 28
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-2005 1017-0155 v1.0 18 As a result the system software file will be stored on the location from where you started the F TP session. 4 T o identify the system so ftware file name, use the quote site software version command: ftp> quote site software version 200- Flash image : 5.4.0.10.0 200- Activ[...]
-
Página 29
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-20051 017-0155 v1.0 19 3.2.2 Upgrade or Restore System Software via FTP Upgrade/Restore procedure The procedure to upgrade or restore the SpeedT ouch™ system software consists of three main steps: Step Action 1 T ransfer system softwa re to the SpeedT ouch™ 2 Mark system software file as Passive[...]
-
Página 30
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-2005 1017-0155 v1.0 20 Transfer system software to the SpeedTouch™ T o transfer a system software file stored on your local disk to the SpeedT ouch™, proceed as follo ws: Step Action 1 Open an F TP session to the SpeedT o uch™. At the user name prompt, enter a user name. At the password prompt[...]
-
Página 31
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-20051 017-0155 v1.0 21 As a result the system sof tware file is stored on the ‘/ dl’ subdirectory of the SpeedT ouch™. In addition, the SpeedT ou ch™ will automatically clean its file system. 6 Put the upgrade system software to the SpeedT ouch™ ‘/dl’ subdirectory: ftp> put ZZUIAA5.[...]
-
Página 32
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-2005 1017-0155 v1.0 22 Mark system software file as Passive Software Version Y ou must identify the system software you transferred to th e SpeedT ouch™ ‘/dl’ subdirectory as passive softwa re version to allow the Spee dT ouch™ to mark the file as system software. Proceeding from the same F [...]
-
Página 33
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-20051 017-0155 v1.0 23 3.2.3 Manual System Software Management via BOOTP/TFTP server System software management The SpeedT ouch™ system software can al so be updated based on BOOTP , a standard mechanism used fo r booting diskless stations. The SpeedT ouch™ is able to be placed in BOOTP mode, al[...]
-
Página 34
Chapter 3 SpeedTouch™ System Software E-DOC-CTC-2005 1017-0155 v1.0 24 Procedure T o upgrade/restore the Sp eedT ouch™ system software: Step Action 1 Make sure that your S peedT ouch™ is powered off and that a BOOTP/ TF TP server is readil y installed on the computer from which you intend to perform the system software upgrade 2 Configure the[...]
-
Página 35
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 25 4 SpeedTouch™ Configuration Management Saving the configuration Whenever the configuration of the SpeedT ou ch™ has been altered in any way , with the intention to keep this conf iguration, you should save it. Y ou can save the configurat ion manu ally in two way[...]
-
Página 36
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 26 4.1 Configuration Management via the SpeedTouch™ Web Interface Basic and expert mod e The SpeedT ouch™ features two ways of managing its configuration via the W eb Interfac e: Via the basic W eb Interface Via the expert W eb Interface Backing up configura[...]
-
Página 37
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 27 Restoring configurations via the basic Web Interface Proceed as follo ws: Step Action 1 Open a web browser and g o to the SpeedT ouch™ W eb Interface. 2 Go to Home > Sp eedT ouch > Co nfiguration. 3 Click Save or Restore Co nfiguration: 4 Click on Browse and [...]
-
Página 38
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 28 Backing up saved configurations via the expert Web Interface Proceed as follo ws: Step Action 1 Open a web browser and g o to the SpeedT ouch™ W eb Interface. 2 Go to expert mode . 3 Click Save All to save the current configuration. 4 Open the Update page via H ome[...]
-
Página 39
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 29 Restoring a configuration via the expert pages Proceed as follo ws: Step Action 1 Open a web browser and g o to the SpeedT ouch™ W eb Interface. 2 Go to expert mode . 3 Open the Upg rade page vi a Home > SpeedT ouch > System Update : 4 Click Browse to locate [...]
-
Página 40
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 30 4.2 Configuration Management via Telnet FTP access For more info rmation on the file s ystem of the SpeedT ouch™ and how to access it via F TP , see “7 The SpeedT ouch™ File System” on page 75 . SpeedTouch™ configuration files The SpeedT ouch™’ s last s[...]
-
Página 41
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 31 4.3 The :Config CLI Command Group Introduction The config CLI command g roup allows the manag ement of SpeedT ouch™ configurations. Following CLI co mmands are available in th e config CLI command g roup: :config CLI commands Below the CLI commands available for Sp[...]
-
Página 42
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 32 Applying a configuration stored on the SpeedTouch™ T o activate a configuration file, stored on the SpeedT ouch™ ‘/dl’ subdirectory , the CLI command :config load is used. Following CLI commands are available in the config load C LI command group: Following p[...]
-
Página 43
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 33 4.3.1 Back up Configurations via FTP Introduction For backup reasons, yo u can transfer configuration files from both the SpeedT ouch™ ‘/active’ and ‘/dl’ subd irectories to your local disk. Backup procedure T o backup the current SpeedT ouch™ configurati[...]
-
Página 44
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 34 As a result th e configuratio n file, cont aining a saved SpeedT o u ch™ configuratio n will be stored on the location fr om where you started the F TP session. 6 Optionally , you can make a listing of the subdirectory’ s contents: ftp> dir 200 Connected to 19[...]
-
Página 45
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 35 4.3.2 Store Configurations via FTP Introduction Via the procedure described below you can: Restore a configuration file you pr eviously backed up via the procedure described in “4.3.1 Back up Configurations via F TP” on pa ge 33 . Apply a new conf igurati[...]
-
Página 46
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 36 Transfer the configuration file to the SpeedTouch™ T o transfer a SpeedT ouch™ configuration file stored on your local disk to the SpeedT ouch™, pr oceed as follows: Step Action 1 Open an F TP session to the SpeedT o uch™. At the user nam e prompt, enter a us[...]
-
Página 47
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 37 8 Put the configurat ion file to the SpeedT ouch™ ‘/dl’ subdirectory: ftp> put config.ini 200 Connected to 192.168.1.254 port 1657 150 Opening data connection for config.ini ## 226 File written successfully ftp: 4472 bytes sent in 0.02Seconds 223.60Kbytes/se[...]
-
Página 48
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 38 Applying a configuration stored on the SpeedTouch™ T o activate a configuration file, stored on the SpeedT ouch™ ‘/dl’ subdirectory , the CLI command :config load is used. Below the syntax of the con fig load CLI command is pro vided: Proceeding fr om the sam[...]
-
Página 49
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 39 In case the file name of the configuration file is different from user .ini, you should specify the file nam e. This allows you to store multiple con figuration files on the SpeedT ouch™ file system, a nd load them when needed: ftp> dir 200 Connected to 192.168.[...]
-
Página 50
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 40 4.4 SpeedTouch™ Service Templates Introduction T emplate files are ASCII text files consisting of a set of SpeedT ouch™ (embedded) Easy Setup wiza rd specific commands and CLI commands. Used by the SpeedT ouch™ (embed ded) Ea sy Setup wizard, template files all[...]
-
Página 51
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 41 4.5 SpeedTouch™ System Languages Management Introduction The following three acti ons are possible regard ing the system languages. Upload a new s ystem language file, which can be found on the SpeedT ouch™ Setup CD, to the SpeedT ouch™. Switch between [...]
-
Página 52
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 42 Switch between system languages T o switch between system la nguages, select the desired syste m language in the system language bar . The system language bar can be foun d on the top right side of the SpeedT ouch ™ W eb Interface: By default, the SpeedT ouch™ is[...]
-
Página 53
Chapter 4 SpeedTouch™ Configuration Managemen t E-DOC-CTC-20051 017-0155 v1.0 43 Delete a system language Proceed as follo ws: Step Action 1 Open a web browser and go to the Spe edT ouch™ Web Interface. 2 Go to the Expert Mode . 3 Open the langua ge page via Home > SpeedT ouch > System Update . 4 Click on the Language Packs tab: 5 Select [...]
-
Página 54
Chapter 4 SpeedTouch™ Configuration Managem ent E-DOC-CTC-2005 1017-0155 v1.0 44[...]
-
Página 55
Chapter 5 SpeedTouch™ So ftware Modules E-DOC-CTC-20051 017-0155 v1.0 45 5 SpeedTouch™ Software Modules SpeedTouch™ software module functionality The SpeedT ouch™ comes by default with an extended set of features to provid e end-to-end connectivi ty over the DSL line, IP Rout ing, RIP , Hyper-NA T , SNMP , Syslog, DHCP , DNS, Remote Assista[...]
-
Página 56
Chapter 5 SpeedTouch™ Softwar e Modules E-DOC-CTC-2005 1017-0155 v1.0 46 5.1 Software Activation Key Management The SpeedTouch™ Software Modules web page Via the SpeedT ouch™ web interface you can easily overview the SpeedT ouch™ available software ac tivation keys and their current status: The Software Module Status Display shows the avail[...]
-
Página 57
Chapter 5 SpeedTouch™ So ftware Modules E-DOC-CTC-20051 017-0155 v1.0 47 Software activation key management via the CLI Y ou can ove rview the softw are modules an d their status and li nk information via the SpeedT ouch™ Command Line Interface (CLI). See “2 SpeedT ouch ™ Command Lin e Interface” on pa ge 5 for more information on how to [...]
-
Página 58
Chapter 5 SpeedTouch™ Softwar e Modules E-DOC-CTC-2005 1017-0155 v1.0 48 How to Install a Software Key After applying for a software key , your ISP should provide you with a software key user name and password. Proceed as follow s to install and acti vate the software key via the GUI: The user name and password remain acti ve. If for some reason,[...]
-
Página 59
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 49 6 SpeedTouch™ System Services Overview This chapter covers th e following services: Service See Dynamic DNS 6.1 Simple Network T ime Protocol (SNTP) 6.2 W ebsite Filtering 6.3 Intrusion Detection 6.4 Remote Assistance 6.5[...]
-
Página 60
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 50 6.1 SpeedTouch™ Dynamic DNS Introduction Dynamic DNS is a mechanism, off ered by several dynamic DNS servi ce providers (available through the In ternet) that allows the m apping of a worldwide resolvable static DNS host name to a dynamically (and temporarily) assigned publi[...]
-
Página 61
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 51 The SpeedTouch™ CLI dyndns commands The SpeedT ouch™ all ows configuration of i ts dynamic DNS client functio nality via the :dyndns CLI com mand group: In this command group al l commands are available for ad ding/ deleting and configuring a dy namic DNS client. It contai[...]
-
Página 62
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 52 Example dynamic DNS subscription For this example, follo wing dynamic DNS subscription is assumed at DynDNS ( www .dyndns.org ): Adding a dynamic DNS host name In a first step you must specify for wh ich hostname(s) you wa nt to enable the dynamic DNS service fo r . According [...]
-
Página 63
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 53 Modifying the dynamic DNS client Now the dynamic DNS client must be co nfigured according your dynami c DNS subscription. Acco rding the Example dynam ic DNS subscription information, following conf iguration must be do ne: => :dyndns modify name = MyDynDNS [intf] = PPPoE_1[...]
-
Página 64
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 54 Refining the dynamic DNS service settings If needed or required by the dynamic DN S service provider , yo u can change some details of the dy namic DNS service. The Example dynamic DNS subscription at DynDNS requires no changes in the service settings, as the pre-config ured s[...]
-
Página 65
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 55 Enabling the Dynamic DNS Service In a final step you must enable the dynamic DNS client: Checking dynamic DNS client Resolving Y ou can easily check whethe r the dynamic DNS client is successfully updating the SpeedT ouch™ public IP address toward s the dynami c DNS service [...]
-
Página 66
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 56 6.2 The SpeedTouch™ SNTP Client Introduction The SpeedT ouch™ Simple Network T ime Protocol (SNTP) client allows you to configure the SpeedT ouch™ in ternal real-time clock (R TC ), used for time-critical operations, for example for online certif icates enrolment (IPSec [...]
-
Página 67
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 57 The Manual tab Select Manual to: Set a date manually . (format dd/mm/yyyy) Set a time manually . (format HH:mm:ss) Select a geographical timezone. (from GMT -12:00 to GMT+ 12:00) Enable or disable sum mertime. ! The Manual T A B, if selected, disa bles the Spee[...]
-
Página 68
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 58 The SNTP tab T o enable the SpeedT ouch™ SNTP client, select the SNTP TA B : As long no NTP servers are configured , time will not be co ntrolled by SNTP . Proceed as follo ws to add an NTP server: From now on, your SpeedT ouch™’ s intern al clock will be synchronized ev[...]
-
Página 69
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 59 Setting the time via CLI The :system rtc settime CLI command allows you to overview the current real-time clock settings and to configure them: Y ou can also use th is CLI command to ma nu ally set the SpeedT ou ch™ internal real- time clock: SNTP via the CLI The SpeedT o uc[...]
-
Página 70
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 60 6.3 Website Filtering About W ebsite Filter ing The website filtering feature offers you the possibility to contro l Internet Access by filtering blocking access to certain webs ites. The SpeedT ouch™ has two methods of controlling access to the Internet: Address Based Fi lt[...]
-
Página 71
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 61 Content Based Filtering With con tent based filtering, you can blo ck or allow access to web sites based on their content. T o do this, yo u can apply a content level as filter . Y ou can use (an, if necessary , customize) on e of the predefine d content levels or create your [...]
-
Página 72
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 62 6.3.1 The Website Filter ing Configuration Pages Page Overview The website filtering sectio n of the SpeedT ouch™ web inter face offers three pages: Page Description Overview Allows you to view the filtering configuration Configure Allows you to config ure website filtering [...]
-
Página 73
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 63 6.3.2 How to Verify the Filtering Configuration Procedure Proceed as follow s to verify th e website filtering configuration: Result: you are taken to the website filtering overview page: Step Action 1 Go to the SpeedT ouch™ configuration home page 2 In the T oolbox section,[...]
-
Página 74
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 64 The Website Filtering Web page This page has two sections: Section Description Filtering Informati on This section provid es information on th e active filterin g configura tion: Address based filtering information: a list of all specified websites and th e actions to be t[...]
-
Página 75
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 65 6.3.3 How to Activate a Web Filtering License Prerequisite Before you can activate the we b site filtering license, yo u need a valid license key . Procedure Proceed as follows to activate a web filterin g license: Step Action 1 Go to the SpeedT ouch™ configuration home page[...]
-
Página 76
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 66 6.3.4 Configuring the Actions for Uncategorised Sites Filter Priority The address based filter , if activated, has the highest priority . Fo r web sites that are not specified in the ad dress based filter , the syste m uses the Content based filte r (if activated). If neither [...]
-
Página 77
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 67 6.3.5 How to Create an Address Based Filter How to Create a New Entry Proceed as follo ws: How to Modify an Entry Proceed as fol lows to modify an entry in the filter table: How to Delete an Entry Proceed as follows to delete an entry in the filter table: Step Action 1 Go to t[...]
-
Página 78
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 68 6.3.6 How to Create a Content Based Filter About Content Levels Content levels determine whic h web sites will be targeted by the filter , based on their content. There are 5 pre-defined content levels: Procedure Proceed as follow s to create a content based fil ter: Level Des[...]
-
Página 79
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 69 6.3.7 How to Create a Content Level How to get a Detailed View Proceeds as follows to get a detailed view of an content level: How to Edit a Conten t Level Proceed as follo ws to edit an existing Content Level: Step Action 1 Go to the W eb site filtering Ove rview page. Result[...]
-
Página 80
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 70 How to Create a New Content Level Proceed as follows to create a new content level: Step Action 1 Go to the W eb site filtering Configure page 2 In the Pick a T ask... list, select Create a new content level. 3 Fill in a name and a description and click Next 4 If you want to: [...]
-
Página 81
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 71 6.4 Intrusion Detection and Protection About Intrusion Detection The SpeedT ouch™ actively prot ects your system against malicious intrusion. Y ou can view statistics on the intrusion at tempts the SpeedT ouch™ has detected. How to View the Intrusion Detection statistics P[...]
-
Página 82
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 72 6.5 Remote Assistance About Remote Assistance Remote Assistance allows you to log on to the SpeedT ouch™ from a remote location and perform tasks. How to Set Up Remote Assistance Proceed as follo ws to set up Remote Assi stance: How to Log On To The SpeedTouch™ Remotely Pr[...]
-
Página 83
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-20051 017-0155 v1.0 73 Connection Type On most variants, th e connection will be HTTPS (secure HT TP). However , some variants do not support SSH and will therefor e use an HTTP connection;[...]
-
Página 84
Chapter 6 SpeedTouch™ System Services E-DOC-CTC-2005 1017-0155 v1.0 74[...]
-
Página 85
Chapter 7 The SpeedTouch™ File System E-DOC-CTC-20051 017-0155 v1.0 75 7 The SpeedTouch™ File System Introduction The SpeedT ouch™ file system exists of nonvolatile memory respon sible for storing, retrieving and maintaining t he system sof tware files, configuration profile files, language-pack files, sof tware activation keys, secure stor a[...]
-
Página 86
Chapter 7 The SpeedTouch™ File System E-DOC-CTC-2005 1017-0155 v1.0 76 Access rights to the file system Following access/action ri ghts apply to the direct ories and its contents: 'root' Directory Access is allowed No Read access No Wr ite access '/active' Subdirectory Access is allowed Listing of f[...]
-
Página 87
Chapter 7 The SpeedTouch™ File System E-DOC-CTC-20051 017-0155 v1.0 77 Files stored on the file system The following is an example output o f the SpeedT ouch™ ‘/dl’ and ‘/active’ subdirectory content: C:Documents and Settingsjohn_doe> ftp 192.168.1.254 Connected to 192.168.1.254. 220 Inactivity timer = 120 seconds. Use 'site i[...]
-
Página 88
Chapter 7 The SpeedTouch™ File System E-DOC-CTC-2005 1017-0155 v1.0 78 File types Followin g file types can be foun d: System software files (e.g. ZZUIAA5.321) The SpeedT ouch™ system software file. Th e one in the ‘/acti ve’ directory is currently used by the SpeedT ouch™; the one in the ‘/dl’ directory is dorm ant. Software [...]
-
Página 89
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 79 8S p e e d T o u c h ™ R e m o t e A c c e s s The SpeedTouch™ access methods The SpeedT ouch™ of fers various access methods to all ow configuration an d monitoring of the device. SpeedT ouch™ HTTP SpeedT ouch™ HTTPs access SpeedT ouch™ T elnet access ?[...]
-
Página 90
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 80 Interface access list The interface acc ess list of a service co ntains the interface groups from where a user is allowed access to th at specific service. The interface access list can contain 1 or more o f the following groups: lan: the local or corporate network local[...]
-
Página 91
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 81 8.1 Remote Web Interface Access Introduction The SpeedT ouch™ web interface is provided by the SpeedT ouch™ HTTP web server . Access to this server and hence the web interfac e is controlled by the HTTP service. By default, the HTTP service is co nfigured to let the we b se[...]
-
Página 92
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 82 Refinement of the Service If needed, the service can be fine-tu ne d to restrict the allowed traffic to: A single IP address A subnet A range of IP addresses Use the following CLI command to restrict the allowed traffic to 1 IP address. Use the following CLI command [...]
-
Página 93
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 83 Hyper-NAT Refinements The SpeedT ouch™ feature s a powerful Hyper-NA T engine allowing the local hosts to share a single (remotely ne gotiated) pu blic IP address. In case Hyper -NA T is enabled on the W AN interface that will be used for remote management, and a static mapp [...]
-
Página 94
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 84 8.2 Secure Remote Web Interface Access HTTPs service Introduction The SpeedT ouch™ supp orts secure HTTP or HTTPS. The T ransport Layer Security (prior SSL implemented by Netscape) provid es communicatio ns privacy over the Internet. The protocol allows client/server applicati[...]
-
Página 95
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 85 Configuration via CLI commands T o have HTTPs access via W AN, additional configuration of the HTTPs service is needed. Use the following CLI command to allow HTT Ps access from the W AN to the SpeedT ouch™: If you take a look at the HTTPs servic e configuration, you will see[...]
-
Página 96
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 86 Refinement of the Service If needed, the service can be fine-tu ne d to restrict the allowed traffic to: A single IP address A subnet A range of IP addresses Use the following CLI command to restrict the allowed traffic to 1 IP address. Use the following CLI command [...]
-
Página 97
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 87 Hyper-NAT Refinements The SpeedT ouch™ feature s a powerful Hyper-NA T engine allowing the local hosts to share a single (remotely ne gotiated) pu blic IP address. In case Hyper -NA T is enabled on the W AN interface that will be used for remote management, and a static mapp [...]
-
Página 98
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 88 8.3 Remote Telnet Access About Secure Remote Telnet Access and SSH The SpeedT ouch™ T elnet host is provid ed by the SpeedT ouch™ T elnet server . Access to this server and hence the T elnet interface is controlled by the T elnet service. By default, the T elnet service is c[...]
-
Página 99
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 89 Refinement of the Service If needed, the service can be fine-tu ne d to restrict the allowed traffic to: A single IP address A subnet A range of IP addresses Use the following CLI command to restrict the allowed traffic to 1 IP address. Use the following CLI command[...]
-
Página 100
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 90 Hyper-NAT Refinements The SpeedT ouch™ feature s a powerful Hyper-NA T engine allowing the local hosts to share a single (remotely ne gotiated) pu blic IP address. In case Hyper -NA T is enabled on the W AN interface that will be used for remote management, and a static mappin[...]
-
Página 101
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 91 8.4 Remote SSH Access SSH service Introduction SSH (Secure Shell) is to be used to esta blish privacy between 2 network devices. It provides a secured layer on top of TCP/IP . The implementation of SSH in the SpeedT ou ch™ is mainly ta rget ed to allow privacy for CLI session[...]
-
Página 102
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 92 Public Keys The SpeedT ouch™ su pports management of SSH public keys. T o each public key installed on the SpeedT ou ch™, a role is assigned. This ro le defines the privilege s, a user accessing the SpeedT ouch™, can have. T o view the public keys installed on the SpeedT o[...]
-
Página 103
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 93 Default SSH service configuration Use the following CLI command to see the default SSH service configuration. => :service system list name=SSH expand=enabled Idx Name Protocol SrcPort DstPort Group ---------------------------------------------------------------------- 1 SSH [...]
-
Página 104
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 94 Configuration via CLI commands T o have SSH access via W AN, additional conf iguration of the SSH service is needed. Use the following CLI command to al low SSH access from the W AN to the SpeedT ouch™: If you take a look at the SSH servic e configuration, yo u will see that t[...]
-
Página 105
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 95 Refinement of the Service If needed, the service can be fine-tu ne d to restrict the allowed traffic to: A single IP address A subnet A range of IP addresses Use the following CLI command to restrict the allowed traffic to 1 IP address. Use the following CLI command[...]
-
Página 106
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 96 Hyper-NAT Refinements The SpeedT ouch™ feature s a powerful Hyper-NA T engine allowing the local hosts to share a single (remotely ne gotiated) pu blic IP address. In case Hyper -NA T is enabled on the W AN interface that will be used for remote management, and a static mapp i[...]
-
Página 107
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 97 8.5 Remote FTP Access Introduction The SpeedT ouch™ F TP interface is prov ided by the SpeedT ouch™ F TP server . Access to this server and hence the F TP in terface is controlled by the SpeedT ouch™ F TP service. By default, the F TP service is configured to let th e Spe[...]
-
Página 108
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 98 Refinement of the Service If needed, the service can be fine-tu ne d to restrict the allowed traffic to: A single IP address A subnet A range of IP addresses Use the following CLI command to restrict the allowed traffic to 1 IP address. Use the following CLI command [...]
-
Página 109
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 99 Hyper-NAT Refinements The SpeedT ouch™ feature s a powerful Hyper-NA T engine allowing the local hosts to share a single (remotely ne gotiated) pu blic IP address. In case Hyper -NA T is enabled on the W AN interface that will be used for remote management, and a static mapp [...]
-
Página 110
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 100 8.6 Remote SFTP Access SFTP Introduction SSH is to be used to establish privacy between 2 network devices. It provides a secured layer on top of TCP/IP . S F TP allows privacy durin g file transfer sessions. SSH authentication The SpeedT ouch™ su pports the following authenti[...]
-
Página 111
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 101 Public Keys The SpeedT ouch™ su pports management of SSH public keys. T o each public key installed on the SpeedT ou ch™, a role is assigned. This ro le defines the privilege s, a user accessing the SpeedT ouch™, can have. T o view the public keys installed on the SpeedT[...]
-
Página 112
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 102 Default SSH service configuration Use the following CLI command to see the default SSH service configuration. => :service system list name=SSH expand=enabled Idx Name Protocol SrcPort DstPort Group ---------------------------------------------------------------------- 1 SSH [...]
-
Página 113
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 103 Configuration via CLI commands T o have SSH access via W AN, additional conf iguration of the SSH service is needed. Use the following CLI command to al low SSH access from the W AN to the SpeedT ouch™: If you take a look at the SSH servic e configuration, yo u will see that[...]
-
Página 114
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 104 Refinement of the Service If needed, the service can be fine-tu ne d to restrict the allowed traffic to: A single IP address A subnet A range of IP addresses Use the following CLI command to restrict the allowed traffic to 1 IP address. Use the following CLI command[...]
-
Página 115
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 105 Hyper-NAT Refinements The SpeedT ouch™ feature s a powerful Hyper-NA T engine allowing the local hosts to share a single (remotely ne gotiated) pu blic IP address. In case Hyper -NA T is enabled on the W AN interface that will be used for remote management, and a static mapp[...]
-
Página 116
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 106 8.7 LAN Based Auto-Configuration (LAC) Support (TR-064) About TR-064 The SpeedT ouch™ supports the DSL Fo rum’ s TR-064 T echnical Report on LAN Based Auto-Configuration. This provides th e possibility to auto matically configure the SpeedT ouch™ from a manage ment applic[...]
-
Página 117
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 107 How to Configure LAC: Parameter Descripion The CLI command uses th e following parameters: Parameter Value Description tr64 enabled or disabled Enable or disable LAC/ TR-064 tr64auth enabled or disabled Enable or disable LAC/ TR-064 Security[...]
-
Página 118
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 108 8.8 CPE WAN Management Protocol (CWMP) Support (TR-069) About CWMP The SpeedT ouch™ supports the DSL Forum’ s TR-069 T echnical Report on CWMP . This allows the Speed T ouch™ to be configure d and monitored from a management application runn ing on a remote Auto-Config ur[...]
-
Página 119
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 109 How to View the Configuration From the main prompt, use th e following command to view the CWMP Par ameters: This results in the following typ e of output on the screen, providing an overview of all parameters and their values: Similarly , to view the CWMP Server co nfigur ati[...]
-
Página 120
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 110 How to C onfigu re CWMP: Parameter Descripion The CLI command uses th e following parameters: Parameter Value Description state enabled or disabled Enable or disable the CWMP daemon mode read-only or full Set the operational mode of the CWMP daemon to read- only or full. period[...]
-
Página 121
Chapter 8 SpeedTouch™ Re mote Access E-DOC-CTC-20051 017-0155 v1.0 111 How to Configure the CWMP Server: Syntax From the cwmp server prompt, use the foll owing commands to config ure the CWMP Server parameters: How to Configure the CWMP Server: Parameter Description The CLI command uses th e following parameters: config [url = <string>] [us[...]
-
Página 122
Chapter 8 SpeedTouch™ Remote Access E-DOC-CTC-2005 1017-0155 v1.0 112[...]
-
Página 123
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 113 9 The Integrated SpeedTouch™ ISDN Modem Overview This chapter covers the following topics: Topic See Page About the ISDN Modem 114 How to Configure the ISDN Modem 116 ISDN Backup 117 ISDN Callback 124 ISDN Remote CAPI 131[...]
-
Página 124
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 114 9.1 About the ISDN Modem Introduction Next to the DSL, Ethernet and Wireless interface, the SpeedT o uch™ features an ISDN modem, to allo w the end user Internet connectivity . Scenarios The ISDN modem can be used as: A stand al one W AN interface to connect [...]
-
Página 125
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 115 Scenario examples The following 2 scenari os are examples of using the ISDN mo dem as a responder: Dialling in to the SpeedT ouch™ fo r remote management pu rposes: T ake into account the foll owing co nfiguration factors: Log in with an account that is [...]
-
Página 126
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 116 9.2 How to Configure the ISDN Modem General configuration procedure Proceed as follows to configure the ISDN modem : ISDN group configuration Proceed as follow s to configure a group of allo wed numbers: Step Action 1 Add a new ISDN interface with name ISP1: =>:[...]
-
Página 127
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 117 9.3 ISDN Backup ISDN Backup The SpeedT ouch™ has an ISDN inter face that can be used to create an ISDN backup for the ADSL line. The pr ocess is shown in the diagram be low: When the ADSL line fails, the SpeedT ouch™ establishes a dial-in connection towards th[...]
-
Página 128
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 118 9.3.1 How to Configure the ISDN Dial-In Connection Via the Web Interface Proceed as follows to con figure the ISDN dial-in connection via the W eb interface : Step Action 1 Go to Expert mode 2 Click Connections 3 Click Routed PPoI Result : on the page that appears,[...]
-
Página 129
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 119 . Via CLI Use the following command se quence to configure the IS DN dial-in connection via CLI: 8 Click Other . Result: the Other page appears: 9 Select the Mode ( On-Demand or Always On ) 10 Fill in the idle time l imit. If the connection is O n-Demand, and the [...]
-
Página 130
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 120 CLI Parameters: The table below provides a descripti on of the rel evant parameters: Parameter Value Description intf text string name of the ISDN interface number numeric Dial-in number for the IS DN line mlppp enabled or disabled Enable or disable multilin k ppp.[...]
-
Página 131
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 121 9.3.2 How to Configure the PPP Connection How to Configure the PPP Connection Vi a the Web Interface If you used the W eb interface to con figure the Dial -In connection, you do not n eed any additional configuration. How to Configure the PPP Connection Vi a CLI U[...]
-
Página 132
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 122 CLI Parameters: The table below provides a de scription of th e relevant pa rameters. Do not alter the default value of the parameters not shown i n this table: Parameter Value Description intf text string name of the PPP interface dest text string name of the ISDN[...]
-
Página 133
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 123 demanddi al enabled or disabled Enable or disabl e dial-on-demand (DOD). This means that the system will engage the ISDN backup if the DSL line fils doddelay numeric (in s) Default: 120 Delay duri ng which DOD is disengaged; This interval is meant to allow the DSL[...]
-
Página 134
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 124 9.4 ISDN Callback ISDN Backup The SpeedT ouch™ has an ISDN inter face that can be used to create an ISDN backup for the ADSL line. The pr ocess is shown in the diagram be low: When the ADSL line fails, the SpeedT ouch™ establishes a dial-in connection towards t[...]
-
Página 135
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 125 9.4.1 How to Configure the ISDN Dial-In Connection Via the Web Interface Proceed as follows to con figure the ISDN dial-in connection via the W eb interface : Step Action 1 Go to Expert mode 2 Click Connections 3 Click Routed PPoI Result: on the page that appears,[...]
-
Página 136
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 126 Via CLI Use the following command se quence to configure the IS DN dial-in connection via CLI: 8 Click Other . Result: the Other page appears: 9 Select the Mode ( On-Demand or Always On ) 10 Fill in the idle time l imit. If the connection is O n-Demand, and the con[...]
-
Página 137
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 127 CLI Parameters: The table below provides a descripti on of the rel evant parameters: Parameter Value Description intf text string name of the ISDN interface number numeric Dial-in number for the IS DN line mlppp enabled or disabled Enable or disable multilin k ppp[...]
-
Página 138
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 128 9.4.2 How to Configure the PPP Connection How to Configure the PPP Connection Vi a the Web Interface If you used the W eb interface to con figure the Dial -In connection, you do not n eed any additional configuration. How to Configure the PPP Connection Vi a CLI Us[...]
-
Página 139
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 129 CLI Parameters: The table below provides a de scription of th e relevant pa rameters. Do not alter the default value of the parameters not shown i n this table: Parameter Value Description intf text string name of the PPP interface dest text string name of the ISD[...]
-
Página 140
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 130 demanddi al enabled or disabled Enable or disabl e dial-on-demand (DoD). This means that the system will engage the ISDN backup if the DSL line fils doddelay numeric (in s) Default: 120 Delay duri ng which DoD is disengaged; This interval is meant to allow the DSL [...]
-
Página 141
Chapter 9 The Integrat ed SpeedTouch ™ ISDN Modem E-DOC-CTC-20051 017-0155 v1.0 131 9.5 ISDN Remote CAPI About Remote CAPI Using RemoteCAPI, the ISDN i nterface of the SpeedT ouch™ can be used by PC applications that typi cally need an ISDN board integrated into the PC. About RVS COM R VS COM is an appli cation that allo ws yo u to use voice ba[...]
-
Página 142
Chapter 9 The Integrate d SpeedTouch™ ISDN Modem E-DOC-CTC-2005 1017-0155 v1.0 132 How to Configure the Remote CAPI Client The above installation pr oce dure adds the Remote CAP20 Client application to your system. Y ou can access it via the Control Panel . Proceed as follows to configure this client: How to C onfigu re Remote CAPI via the Web in[...]
-
Página 143
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 133 10 SpeedTouch™ Monitoring Overview This chapter covers th e foll owing topics : Topic See Page 10.1 An Introducti on to SNMP 134 10.2 SNMP configuration 139 10.3 The SpeedT ouch™ Syslog 160 10.4 SpeedT ouch™ Identifica tion on A W S 169[...]
-
Página 144
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 134 10.1 An Introduction to SNMP Introduction The Simple Network Ma nagement Protocol (SNMP) is a widely spread method fo r managing networks. Based on a clie nt/server concept, the SNMP server (the SNMP manager) gets or sets the values of ob jects defined in a Management I nformati[...]
-
Página 145
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 135 10.1.1 Basic Concepts Management Information Base The Management Information Base, or MIB, is a tree-like structure containing SNMP objects, instances of these objects and thei r corresponding values. Parts of this tree have been standardi zed, other part s may be specific to a [...]
-
Página 146
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 136 10.1.2 MIBs Explained. Introduction As mentione d in “ Management Information Base” on page 135 both the SpeedT ouch™ SNMP agent and the SNMP m anager rely on Management Information Base (MI B) files containing all relevant SNMP objects. In the following, al l MIBs importa[...]
-
Página 147
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 137 Standard MIBs (Continued) Continued from previ ous page. RFC1213 MIB II RFC 2790 Host Resources MIB This MIB shows hot resource in formation such as software builds, CPE date and time-of-day , the total and free am ount of Flash Memory and RAM and processor load. RFC[...]
-
Página 148
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 138 ADSL and SHDSL MIBs Following two MIBs are specific per Sp eedT ouch™’ s DSL vari ant (ADSL or SHDSL variants). Y ou sh ould only load the appropria te MIB, although loading both will not harm functionality . T o retrieve ma ximum SN MP information it is imperative to use th[...]
-
Página 149
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 139 10.2 SNMP configuration About SNMP configuration There are a few configurable options cove ring the SNMP functionality . If you require no traps are , the default options suffice to access information in the SpeedT ouch™ from the LAN. Enabling SNMP By default, the SNMP agen t [...]
-
Página 150
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 140 10.2.1 How to Allow Access to the SNMP Agent Default Setting By default, access to the SN MP Agent is di sabled. Before you ar e able to use SNMP , you must enable it. Command Use the following command to a llow access to th e SNMP Agent: :service system modify name=SNMPV3_AGENT[...]
-
Página 151
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 141 10.2.2 How to View the SNMP Configuration About the SNMP Service The SpeedT ouch™ SNMP servic e controls all SNMP tra ffic from and towards the SpeedT ouch™. By default, no restrictions apply regardi ng SNMP traffic from and towards the local network. However SN MP traffic f[...]
-
Página 152
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 142 10.2.3 How to View the System Contact, Name and Location Command Use the following CLI command to view the default configuration: Default Configuration The default configurati on is as follows: {Administrator}[snmp]=>config SNMP System Contact : Service Provider SNMP System N[...]
-
Página 153
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 143 10.2.4 How to Configure SNMPv1 Configuring SNMPv1 on the SpeedTouch™ The SpeedT ouch™ supp orts SNMPv3, but is also backwards compatible with SNMPv1. However , you need specific config uration procedures for this. Basically you need to do the following in order to configure [...]
-
Página 154
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 144 How to Configure the SNMPv1 Traps Proceed as follo ws: Step Action 1 Create a new target: :snmp target add name=Test_trap_pc addr=10.0.0.110 taglist=Trap_tag params=Trap_params 2 Create a notify filter: :snmp notify add name=trap_notify_test tag=Trap_tag 3 Configure the ta rget [...]
-
Página 155
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 145 10.2.5 How to Configure the System contact, Name and Location Command Y ou can set the System contact, System Na me and the System Lo cation in the MIB II RFC1213. Use the followin g CLI command to do so: Parameters Thi s command has the follo wing parameters: config [sysContact[...]
-
Página 156
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 146 10.2.6 How to Force the Source IP Address About Loopback The SpeedT ouch ™ offers the po ssibility to send SNMP tr aps to an SNMP manager . This facilitates the monitoring of the network. I t is importan t that the sou rce IP address of the SNMP traps remains the same at all t[...]
-
Página 157
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 147 10.2.7 How to Configure the SNMP Target About the SNMP Target The SNMP target is the destination for th e SNMP t raps , e.g an SN MP M anag er . Y ou can add up to nine differen t SNMP manager destination ad dresses, using the :snmp target add command. Command Use the following [...]
-
Página 158
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 148 Use of defaults If you do not specify a parameter , defaul t value s are used. The key parameters are name and addr . How to Delete a Destination T o delete a manage r destinatio n, use : taglist <quoted string> S tring containing one or more tags. A tag corresponds to a t[...]
-
Página 159
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 149 10.2.8 How to Read SNMP Parameters via the CLI About Reading SNMP Parameters The snmp get , snmp getNext and snmp walk commands allow you to Get, GetNext or W alk SNMP settings and/or coun ters from a MIB object. The MIB object is identified by th e MIB object’ s ID. This is o[...]
-
Página 160
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 150 SNMP w alk Use the following CLI com mand to skim throug h a MIB object: Example: For example, o bjectid .1.3 .6.1.2.1.1, iden tifies the SpeedT ouch ™ MIB system grou p. The example below skims through this M IB object: {Administrator}[snmp]=> walk [objectid = <string&g[...]
-
Página 161
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 151 10.2.9 How to Allow Remote SNMP About Remote SNMP It is possible to allow to allow a re mote SNMP manage r to monitor the SpeedT ouch™. T o do this, add the W AN interface to the se rvice access list. Command Use the following command: Receiving Traps T o allow the remote SNMP[...]
-
Página 162
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 152 10.2.10 How to Add an SNMP User About SNMP Users SNMP Users al low you to determine which MIBs a specific user is allowed t o view or change. This is don e by adding a user to a user group. This user group determines the user’ s access to the MIBs. Limiting MIB Access Y o u ca[...]
-
Página 163
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 153 Case As an example, we will create the following: A new user group called “Grayskull” A new user called “Musclor” A new view called “View_All” The user has full rig hts (read, write and not ification) to all MIBs. Power User Has the same rights as Us er ,[...]
-
Página 164
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 154 Procedure The general flow of user configuratio n is as follows: you creat e a view , which is basically a set of MIB access right s. after that, you create a user group with access to that view . Then, you create a user and add it to the group. Thus, th e user will have the gro[...]
-
Página 165
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 155 How to View the Users Use the following command to view the users: This result s in the followin g output: :snmp user list securityname=SU snmpengineID=localSnmpID authprot=usmNoAuthProtocol privprot=usmNoPrivProtocol targettag= storage=nonVolatile securityname=user snmpengineID[...]
-
Página 166
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 156 How to View the Communities Use the following command to view the communities: This result s in the followin g output: For backwards compatib ility purposes, some default s were added. :snmp securiytogroup list securitymodel=snmpv1 securityname=ROCommunity groupname=V1ROGroup st[...]
-
Página 167
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 157 10.2.11 How to Restrict SNMP Access SNMP Access Restriction Y ou can restrict SNMP Access so that it is accepted from specif ic IP add resses only . T o do this, add the IP address or an IP Address range to the access list for the service SNMPV3_Agent. No te that this also cover[...]
-
Página 168
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 158 10.2.12 How to Configure the Traps Procedure In order to configure which traps are sent where, you need to: If you simply want all tags to be se nt, steps 2, 3 and 4 are not necessary . How to Set the Message Handling Parameters Use the :snmp targetparams add command. Example: H[...]
-
Página 169
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 159 How to Create a Destination for theTraps Use the :snmp target add command. Example: How to Enable Traps Use the following command sequence: More Information For more information abou t these commands, refer to th e CLI Command Guide :snmp target add name=Test_trap_pc addr=10.0.0[...]
-
Página 170
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 160 10.3 The SpeedTouch™ Syslog Introduction Syslog is a basic, uncomplicated, yet powerful m ethod to administer a network device as the SpeedT ouch™. By generating syslog messages, the SpeedT ouch™ is able to inform network ma nagers about the general st ate of the device an[...]
-
Página 171
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 161 10.3.1 The SpeedTouch™ Syslog Daemon What is Syslog Syslog is a message generating tool th at can be implemented in any network device. The intent ion of the tool is to send messages over th e network indicating status, actions, possi ble problems, etc. from the de vice. Altho[...]
-
Página 172
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 162 Syslog priority facilities Following priority facili ties are possibl e for a syslog message generated by the SpeedT ouch™. The facilities are listed by descending priority: Priority Notation Code Kernel messages kern 0 User -level messages user 8 Mail system mail 16 System da[...]
-
Página 173
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 163 Syslog message bodies The SpeedT ouch™ syslog daem on is internally responsibl e for collecting and administering messages genera ted by one or more of its subsystems. Fo llowing of the SpeedT ouch™ subsystems ar e able to trigger a message: Auto-PVC module Configura[...]
-
Página 174
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 164 10.3.2 Syslog via the Web Interface The Syslog web page The SpeedT ouch™ Sysl og web page allows us ers to view all or a selectio n of syslog messages the SpeedT ouch™ has gene ra ted. Browse to the Speed T ouch™ Expert pages and open the Syslog pag es via Home > SpeedT[...]
-
Página 175
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 165 Syslog configuration Via the SpeedT ouch™ Syslog page, you can also configure the SpeedT ouch™ syslog daemon to send sysl og messages to one or more particular host IP addresses. This allows dedicated syslog software on the host to collec t SpeedT ouch™syslog messages for [...]
-
Página 176
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 166 10.3.3 Syslog via the CLI The Syslog CLI command group The SpeedT ouch™ CLI syslog command grou p basically provides the same possi- bilities as provided on the Spee dT ouch™ syslog web pa ge: T o display a listing of al l generated syslog messa ges, use following CLI comman[...]
-
Página 177
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 167 10.3.4 Remote Syslog Notification Introduction The SpeedT ouch™ can be configured to send all or a selection of generated syslog messages to a host on the local or a remote network IP address. This section describes how to configure the SpeedT ouch ™ syslog daem on to send m[...]
-
Página 178
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 168 Syslog host on a remote network The default SYSLOG SpeedT ouch™ service is configured to allo w traffic from the SpeedT ouch™ syslog da emon towards the W AN: Therefore, no additional con figuration i s needed in case you want to configure a syslog host on a remote network. [...]
-
Página 179
Chapter 10 SpeedTouch™ Monitorin g E-DOC-CTC-20051 017-0155 v1.0 169 10.4 SpeedTouch™ Identification on AWS Information Exchange The SpeedT ouch™ ex changes some variables after the DSL synch ronisation with the DSLAM (Digital Subscriber Line Acce ss Multiplexer). These va riables are hard- coded into the SpeedT ouch™. The following variabl[...]
-
Página 180
Chapter 10 SpeedTouch™ Mon itoring E-DOC-CTC-2005 1017-0155 v1.0 170 SpeedTouch™ Identification over AWS The ADSL W ork Station (A WS) is the graphical managem ent tool to control and configure DSL lines on a DSLAM. The figure below is an exampl e of a screenshot of an A WS. ! The CPE Remote Inventory displays the values in a HEX notation.[...]
-
Página 181
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 171 11 SpeedTouch™ Advanced Diagnostics About the Advanced Diagnostics The SpeedT ouch™ features advanced diagnostic s to allow for extended moni toring of the system’ s performance, operation and connection status. Y ou can access the diagnostics either with the W e [...]
-
Página 182
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 172 11.1 The Office Network Web Page About the Office Network Web Page The Office Network Web page shows all devices on the LAN and their main characteristics: How to Access the Office Network Page Proceed as follo ws: Additional Pages There are two additional pages availa[...]
-
Página 183
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 173 The Devices Page The Devices pa ge provides informatio n on the devices present on the LAN: T o see more details of a specific device, click on the corresponding device name, e.g. a00098 in the above example: From these pages you c an also perform the fo llowing tasks: [...]
-
Página 184
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 174 The Interfaces Page The Devices page provides informatio n on the devices present on the LAN: T o see more details of a specific interface, click on the correspo nding interface name, e.g. lan1 in the above example:[...]
-
Página 185
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 175 11.2 The Diagnostic Web Page Introduction In this section the Diagnostic W eb Page is described. Opening the SpeedTouch™ Diagnostic Web Interface Proceed as follo ws: 1 Open a web brows er an go to the SpeedT ouch™ W eb Interface. 2 Go to the Ex pert Mode pages. 3 O[...]
-
Página 186
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 176 System Diagnostics Use the expand button (or Expand all ) to open the Sy stem Diagnost ics: The information shown is mainly meant for uniquely identifyi ng your device (for example as referenc e for helpde sking). Among others, following info rmation is provided: D[...]
-
Página 187
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 177 LAN Diagnostics Use the expand button (or Expand all ) to open the LAN Diagnostics: The LAN Diagnostics provide informatio n on the SpeedT ouch™’ s local network Ethernet interface(s). Per Ethernet interface a visu al indicator shows whether: Per interface followi n[...]
-
Página 188
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 178 WAN Diagnostics Use the expand button (or Expand all ) to open the W AN Diagnostics: The W AN diagnostics consists b asically of two expandable parts: The physical layer DSL diagnostics: Next to some general information on the DSL line flavour , status, bandwidth c[...]
-
Página 189
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 179 11.3 Command Line Interface Diagnostics Overview This chapter covers the following topics: Topic See Page About CLI Diagno stics 180 Lower Layer Diagnostics 181 Router Services Diagnostics 184 Routing Diagnostics 186 Ethernet Diagnostics 189 Management Diagnostics 191[...]
-
Página 190
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 180 11.3.1 About CLI Diagnostics Introduction This section describes some of the diagnostics availa ble from the SpeedT ouch™ Command Line In terface (CLI). For a full descriptio n of the CLI commands see the “SpeedT o uch™ CLI Reference Guide” for more infor matio[...]
-
Página 191
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 181 11.3.2 Lower Layer Diagnostics ADSL The :adsl info displays ADSL statistics and infor mation on current SpeedT ouch™ DSL line status. Although it is the same comm and for both SpeedT ouch™ ADSL/POTS and ADSL/ ISDN variants, the command features specif ic output para[...]
-
Página 192
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 182 ATM Several commands are available to display specific Asynchronous T ransfer Mode (A TM) statistics: :atm debug aal5stats Displays A AL5 port sp ecific Asyn chro nous T ransfer Mode (A TM) statistics :atm debug gstats Displays global A TM statistics :atm d[...]
-
Página 193
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 183 ATM Auto-Configuration via TR-37/ ILMI 4.0 The ILMI operates between the network and the A TM Network T ermination at the customer premises for example the SpeedT ouch™. ILMI 4.0 is supported on VP /VC 0/16. Meaning that the VCC or VPC can be provisioned via this mana[...]
-
Página 194
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 184 11.3.3 Router Services Diagnostics DHCP Following DHCP stat istics are available: :dhcp client debug stats Displays statistics of SpeedT ouch™’ s DHCP client :dhcp server debug stats Displays statistics of SpeedT ouch™’ s DHCP server :dhcp relay deb[...]
-
Página 195
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 185 DNS Following DNS server/forwarding statistics are available: :dns server debug stats Displays statistics of SpeedT o uch™’ s DNS server/forwarder => :dns server debug stats Corrupted packets received : 1 Local questions resolved : 5 Local negative answers se[...]
-
Página 196
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 186 11.3.4 Routing Diagnostics Firewall Rule T o check th e operation of the SpeedT ou ch™ packet firewall followin g command is available: :firewall rule debug stats Displays per firewall ru le, the number of packets (and corres ponding bytes) that passed the firewa[...]
-
Página 197
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 187 IP Diagnostics There are two useful commands: ping: Send IGMP ECHO_REQUEST packets to a given destin ation traceroute: Send ICMP/U DP packets to trac e the ip path. Each of these can be gi ven from the root of the CLI, as well as from any other place in any comm[...]
-
Página 198
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 188 The Traceroute Command The traceroute command ha s the following syntax: It uses the following pa rameters: Example Below is an example of a trac eroute command and its reply: traceroute addr = <ip-address> [count = <number{1-10}>] [size = <number{1-2000[...]
-
Página 199
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 189 11.3.5 Ethernet Diagnostics Non-intrusive Sniffing For debugging purposes, the SpeedT o uch™ offers a port mirrorin g feature. This means that, three out of the four physical eth ernet ports can be used for network connections, wh ile the remaining ethernet port can b[...]
-
Página 200
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 190 T o verify which port is being mirrored (ingress or egres s) use the following commands: When there is no need to mirror traffic to ethernet po rt four any more you can disable the mirroring by executing the follo wing command: => :eth switch mirror ingress Ingress [...]
-
Página 201
Chapter 11 SpeedTouch™ Advanced Diagnostics E-DOC-CTC-20051 017-0155 v1.0 191 11.3.6 Management Diagnostics SNMP and Syslog The SpeedT ouch™ Simple Network M anagement Protocol (SNM P) and Syslog modules are industry stand ard management utilit ies to diagnose the device ’ s status, connections, etc. For a full description of the SpeedT ouch?[...]
-
Página 202
Chapter 11 SpeedTouch™ Advan ced Diagnostics E-DOC-CTC-2005 1017-0155 v1.0 192[...]
-
Página 203
Chapter 12 SLA Monitoring. E-DOC-CTC-20051 017-0155 v1.0 193 12 SLA Monitoring. Introduction The SpeedT ouch™ supp orts Service Le vel Agreeme nt/QoS monitoring on a continuous basis. An extended ping or tr ace route process can be started from the SpeedT ouch™ to another node in the worldwide IP network, to measure the QoS (round-trip delay , [...]
-
Página 204
Chapter 12 SLA Monitoring. E-DOC-CTC-2005 1017-0155 v1.0 194 Now that we defined an SLA ping test we need to configure th e test. The following parameters can be configur ed: Parameter Description Values test The name of th e ping test to configure. string addr The destinat ion IP address. string size The size of the data portion to be transmitted [...]
-
Página 205
Chapter 12 SLA Monitoring. E-DOC-CTC-20051 017-0155 v1.0 195 Use the following command to modify th e SLA ping parameters: Starting the SLA Ping The SLA Ping process has been configured now . Y ou now need to start the process, to do so, use the fo llowing command: SLA Ping Result Now that the SLA ping process has been starte d you can view the SLA[...]
-
Página 206
Chapter 12 SLA Monitoring. E-DOC-CTC-2005 1017-0155 v1.0 196 Following results will be displayed : SLA Ping History A complete list of the SLA pings send can be view as well. T o do so, use the following CLI command : Name Description status In Progress, Stopped minrtt Minimum RT T (Round-T rip-T ime): microseconds maxrtt Maximum RTT : microseconds[...]
-
Página 207
Chapter 12 SLA Monitoring. E-DOC-CTC-20051 017-0155 v1.0 197 Traceroute Process T raceroute is usually implemented by tran smitting a series of probe packets with increasing time-to-live values. A probe pa cket is a UDP datagram encapsulated into an IP packet. Each hop in a path to the target (destination) ho st rejects the probe packet (pro be&apo[...]
-
Página 208
Chapter 12 SLA Monitoring. E-DOC-CTC-2005 1017-0155 v1.0 198 Now that we defined an SLA ping test we need to configure th e test. The following parameters can be configur ed: Parameter Description Values test The name of the traceroute test to configure. string addr The destinat ion IP address. string size The size of the data portion to be transmi[...]
-
Página 209
Chapter 12 SLA Monitoring. E-DOC-CTC-20051 017-0155 v1.0 199 Use the following comman d to modify the SLA tr aceroute parameters: Starting the SLA Traceroute The SLA traceroute process has been config ured now . Y ou now need to start the process, to do so, use the following command: maxfail The max number of consecutive timeouts allowed before ter[...]
-
Página 210
Chapter 12 SLA Monitoring. E-DOC-CTC-2005 1017-0155 v1.0 200 SLA Traceroute result Now that the SLA traceroute process ha s been started you can view the SLA traceroute results. Use the following command: => :sla traceroute list route: [owner = modem] dest = 11.0.0.138 size = 0 timeout[s] = 3 probePerHop = 3 port = 33434 maxTTL = 30 InitialTTL =[...]
-
Página 211
Chapter 12 SLA Monitoring. E-DOC-CTC-20051 017-0155 v1.0 201 Following results will be displayed : SLA Traceroute History A history of the SLA traceroute can be view as well. T o do so, use the following CLI command: Name Description status In Progress, Stopped currHopCount Reflects the curren t TTL value (range from 1 to 255) for a traceroute oper[...]
-
Página 212
Chapter 12 SLA Monitoring. E-DOC-CTC-2005 1017-0155 v1.0 202[...]
-
Página 213
Chapter 13 Resetting the Spee dTouch™ E-DOC-CTC-20051 017-0155 v1.0 203 13 Resetting the SpeedTouch™ Introduction If needed you can reset the SpeedT ouch™ to factory defaults or ju st reboot. Normal reboot T o reboot the SpeedT ouch™ without erasing the current configuration,use th e following comma nd: This command will save the current c [...]
-
Página 214
Chapter 13 Resetting the SpeedTouch™ E-DOC-CTC-2005 1017-0155 v1.0 204 The Reset button On the back side of the Spee dT ouch™ there is a resetbutto n. By pressing this b utton for three to six seconds the d evice will reboot an d startup with the settings defined in the isp.def if present. The reset button can be disabled by executing the f oll[...]
-
Página 215
[...]
-
Página 216
Need more help? Additional help is available online at www .speedtouch.com © THOMSON 2006 All rights reserved. E-DOC- CTC-2005101 7-0155 v1.0 .[...]