Metrologic Instruments MS5100 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 52 pages
- 4.55 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Barcode Reader
Metrologic Instruments MS5100
52 pages 4.55 mb -
Barcode Reader
Metrologic Instruments MS2220
86 pages 14.77 mb -
Barcode Reader
Metrologic Instruments 8
5 pages 0.02 mb -
Barcode Reader
Metrologic Instruments MS6520
44 pages 1.49 mb -
Barcode Reader
Metrologic Instruments IS1650
52 pages 5.73 mb -
Barcode Reader
Metrologic Instruments MS863
52 pages 1.06 mb -
Barcode Reader
Metrologic Instruments MLPN 2168
19 pages 0.32 mb -
Barcode Reader
Metrologic Instruments MS7120
52 pages 2.04 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Metrologic Instruments MS5100. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Metrologic Instruments MS5100 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Metrologic Instruments MS5100 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Metrologic Instruments MS5100 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Metrologic Instruments MS5100
- nom du fabricant et année de fabrication Metrologic Instruments MS5100
- instructions d'utilisation, de réglage et d’entretien de l'équipement Metrologic Instruments MS5100
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Metrologic Instruments MS5100 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Metrologic Instruments MS5100 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Metrologic Instruments en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Metrologic Instruments MS5100, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Metrologic Instruments MS5100, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Metrologic Instruments MS5100. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
[...]
-
Page 2
Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or b y any means without prior written consent, except b y reviewer, who may quote brief passages in a review, or provided for in the Cop yright Act of 1976. Trademarks Metrologic is a registered trademar[...]
-
Page 3
ii T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and A ccessori es ................................................................................. 2 Scanner Comp onents ..........................................................................[...]
-
Page 4
iii T ABLE OF C ONTENTS Scanner and Cable Terminati ons Scanner Pinout Connecti ons .......................................................................... 33 Cable Connector C onfigurat ions .................................................................... 35 Regulatory Compliance Safety ......................................................[...]
-
Page 5
1 I NTRODUCTION The MS5145 Eclipse ™ is a single-line, h and-held laser scanner. Equipped with Metrologic’s pa tented CodeGate ® technolo gy, Eclipse can be used in a wide variety of applications. Cod eGate technology allo ws the user to easily target the desired bar c ode and co mplete the data transmission with a simple press of a button. T [...]
-
Page 6
2 I NTRODUCTION Scanner and Accessories B ASI C K IT Part # Description MS5145 Eclipse Scanner 00-02544 x MetroSelect Single-Line Confi guration Guide * 70-79016 x MS5100 Eclipse Series Installation and User ’s Guide * * Available on the Metrologic website - www.metrologic.com O PTIONAL A CCESSORIES Part # Description AC to DC Power Transformer- [...]
-
Page 7
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 55-55000 x -3 RS232 PowerLink Cable with Built in Power Jack 2.1 m (7 ft.) straight cord, long strain relief, black 55-55002 x -3 Keyboard Wedge PowerLink Cabl e with Adapter 2.1 m (7 ft.) straight cord, long strain relief, black 55-55020 x -3 Stand Alone Keyboard Po [...]
-
Page 8
4 I NTRODUCTION Scanner Components I TEM N O . D ESCRIPTION 1 Mode Select Button/CodeGate Button (see page 12) 2 Red LED (see page 14) 3 Green LED (see page 14) 4 Red Output Window (Laser Aperture) 5 Speaker (see page 13) 6 10-Pin RJ45, Female Socket (see page 33) 7 Pin Hole for Cable Release (see page 6) Figure 1. Scanner Components Maintenance Sm[...]
-
Page 9
5 I NTRODUCTION Caution and Serial Number Labels Figure 2. Label Location on the Botto m of the Scanner with Exa mple Caution To maintain compliance w ith applicable standard s, all circuits connected to the scanner must meet the requirements for SELV (S afety E xtr a L ow Voltage) according to EN/IEC 60950-1 . To maintain compliance w ith standard[...]
-
Page 10
6 Figure 5. I NTRODUCTION Cable Removal Disconnect the power supply from the Po werLink cable and turn off power to the host system before removing the cable from the scanner. 1. Locate the small ‘pin-hole’ be neath the Eclipse logo on the front side of the scanner near the end of the handle. 2. Bend an ordinary paperclip into the shape shown. [...]
-
Page 11
7 I NSTALLATION RS232, Light Pen or Laser Emulation 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Connect the 9-Pin female end of the PowerLink cable to the appropriate communication port on the host device. 4. Plug the external power supply into the power jack on the [...]
-
Page 12
8 I NSTALLATION IBM 46xx or OCIA 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS5145. 3. For IBM: connect the other end of the MVC cable to Port 9 of the host device. For OCIA: Connect the other end of the MVC cable to the appropriate communication port on the host device. 4. Turn on t[...]
-
Page 13
9 I NSTALLATION Keyboard Wedge 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Disconnect the keyboard from the host/PC. 4. Connect the Y ends of the PowerLink cable to the keyboard an d the host’s keyboard port. If necessary, use the supplied adapter cabl e to make th[...]
-
Page 14
10 I NSTALLATION Stand-Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the Eclipse. You will hear a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the power supply into the power jack on the Power[...]
-
Page 15
11 Figure 10. USB I NSTALLATION USB : Low Speed USB (-38) Full Speed USB (-40) 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector of the USB cable into the jack on the Eclipse. You will hear a ‘click’ when the connection is made. 3. Connect the other end of the USB cable to the host USB port. 4. Turn on the host system. As a[...]
-
Page 16
12 S CANNER O PERATION How to Use CodeGate and the Manual Activation Mode C ODE G ATE ® M ANUAL A CTIVATION M ODE * * This feature is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode. Figure 11. CodeGate Enabled Figure 12. Manual Activation Mode Two Modes of Operation CodeG[...]
-
Page 17
13 S CANNER O PERATION Indicators Audible When the MS5145 scanner is oper ational, the scanner provides audi ble feedback to indicate the status of the scanner and the last scan. Eight settings are available for the tone of the beep (no rmal , 6 alternate tones and no tone). for instructions on how to change the lo ne of the be eper, refer to the S[...]
-
Page 18
14 S CANNER O PERATION Indicators Visual The MS5145 is equippe d with a red LED and green LED that indicates the scanner’s state and the status of the current scan wh en the unit is in operation. Figure 13. LED Color and Location Green and Red LEDs Ar e Off The LEDs will not be illuminat ed if the scanner is not receiving power from the host or t[...]
-
Page 19
15 S CANNER O PERATION Indicators Failure One Razzberry Tone – On Power Up This indicates the scanner has experi enced a laser or flipper subsystem failure. Return the unit fo r repair to a Metrologic Authorized Service Center. Continuous Razzbe rry Tone with no LEDs If, upon power up, the scanner emits a continuous razzberry tone, then the scann[...]
-
Page 20
16 S CANNER O PERATION Depth of Field vs. Minimum Bar Code Element Width Minimum Bar Code Element Width A B C D E F mm .10 .12 .17 .26 .33 .66 mils 4.1 4.8 6.8 10.4 13 26 Figure 14. Depth of Field vs. Minimum Bar Code Element Width[...]
-
Page 21
17 S CANNER O PERATION Configuration Modes The MS5145 Eclipse has 3 modes of confi guration. • Bar Codes The Eclipse can be configured b y scanning the bar codes located in the MetroSelect ® Single-Line C onfiguration Guide ( MLPN 00-02544). This manual can be downloaded for FREE at www.metrologic.com. • MetroSet ® 2 This user-friendly Window[...]
-
Page 22
18 S CANNER O PERATION 4. During configuration, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL CONFIGURATION MODE. 5. There is a 20 second window bet ween commands. If a 20 second timeout occurs, the scanner will send a [nak] and yo u must start over. 6. To enter serial configuratio n mode, send the following command [stx][...]
-
Page 23
19 S CANNER O PERATION EXAMPLE #3 : The following example sho ws the events that occur when an invalid bar cod e is sent. This sample will load the factory default settings an d then set the baud rate to 19200. FEATURE HOST COMM AND ASCII REPRESENTATION SCANNER RESPONSE Enter Configuration Mode [stx]999999[etx] 02h 39h 39h 39h 39h 39h 39h 03h [ack][...]
-
Page 24
20 T ROUBLESHOOTING G UIDE The following guide is for reference purpos es only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-43 6-3876 to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being supplied to the unit. Check the transformer, the outlet and power strip. Make sure the cab[...]
-
Page 25
21 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not scan and/or beep. The bar code being scanned does not satisfy the configured criteria for character length lock or minimum length. Verify that the bar code being scanned falls into the configured criteria. The scanner defaults to a minimum of 3 c haracter [...]
-
Page 26
22 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit scans but the data is not correct. The unit’s configuration is not correct. Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct country code and data format is selected. Adjust the inter-character delay symptom. The unit is transmitting each characte[...]
-
Page 27
23 RS232 D EMONSTRATION P ROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test t hat the communication port and scanner are work ing. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the COM port is working, and the scanner is wo[...]
-
Page 28
24 D ESIGN S PECIFICATIONS MS5145 Eclipse O PERATIONA L Light Source: V isible L aser D iode (VLD) @ 650 nm Laser Power: Less than 1.0 mW average Depth of Scan Field: 0 mm – 140 mm (0 " – 5.5") 0.33 mm (13 mil) Bar Code Scan Speed: 72 ± 2 scan lines per second Scan Pattern: Single scan line Minimum Bar Width: 0.089 mm (3.5 mil) Decod[...]
-
Page 29
25 D ESIGN S PECIFICATIONS MS5145 Eclipse E LECTRICAL Input Voltage: 5VDC ± 0.25V Power: Operating 675 mW Current: Operating 125 mA average @ 5VDC DC Transformers: Class II; 5.2VDC @ 1A For regulatory compliance inf ormation, see pages 37 – 39. E NVIRONMENTAL Operating 0°C to 40°C (32°F to 104°F) Temperature: Storage -40°C to 60°C (-40°F [...]
-
Page 30
26 A PPLICATIONS AND P ROTOCOLS The model number on each scann er incl udes the scanner number and fa ctory default communications protocol. Scanner Version Identifier Communication Protoc ol(s) 00 Laser Emulation 9 OCIA 11 IBM 468X/469X, RS232 - TXD, RXD, RTS, CTS 38 Low Speed USB, Serial Emulation or Keyboard Emulation 40 Full Speed USB 41 RS232/[...]
-
Page 31
27 D EFAULT S ETTINGS Many functions of the scanner can be configu red or enabled/disab led . The scanner is shipped from the factor y c onfigured to a set of default conditions. All default parameters of t he scanner have an asterisk ( * ) marked in the default column. If an asterisk is not in the def ault column then th e default setting is off o[...]
-
Page 32
28 D EFAULT S ETTINGS Parameter Default OCIA RS232 Light Pen IBM 46xx KBW USB Laser Emulation ITF Symbol Lengths Variable Minimum Symbol Length 3 Symbol Length Lock None Bars High as Code 39 * Spaces High as Code 39 Bars High as Scanned Space[...]
-
Page 33
29 D EFAULT S ETTINGS Parameter Default OCIA RS232 Light Pen IBM 46xx KBW USB Laser Emulation Infinite Same Symbol Timeout Inter-Character D elay Configurable In 1 m sec steps (max 255 msecs) 1 msecs 10 msecs in KBW Number Of Scan Buffers ( maximum ) 4 Transmit UPC-[...]
-
Page 34
30 D EFAULT S ETTINGS Parameter Default OCIA RS232 Light Pen IBM 46xx KBW USB Laser Emulation Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Carriage Return * Line Feed-Disabled by Default in KBW * Tab Prefix Tab Suffix “DE” Disable Command ?[...]
-
Page 35
31 D EFAULT S ETTINGS Parameter Default OCIA RS232 Light Pen IBM 46xx KBW USB Laser Emulation 100 msec to Find Supplement Configurable in 100 mse c steps (max 800 ms ec) * Coupon Code 128 as code 39 as code 39 † Configurable Code Leng ths 7 avail † Code Selects with Con[...]
-
Page 36
32 U PGRADING THE F LASH ROM F IRMWARE The MetroSet2 program is a functional co m ponent of Metrologic’s line of Flash- based scanners. This program allo ws t he user of a Metrologic scanner to quickly upgrade to a new or custom version of soft ware. It requires the use of a personal computer running under Windo ws 95 or greater and the use of a [...]
-
Page 37
33 S CANNER AND C ABLE T ERMINATION S Scanner Pinout Connections The MS5145 scanner interfaces terminate to a 10-pin modular jack. The serial # label indic ates the interface enabled when the scanner is ship ped from the factory. Figure 15. MS5145-41 RS232C and Light Pen Emulation Pin Function 1 Ground 2 RS23 2 Transmit Output 3 RS23 2 Receive Inpu[...]
-
Page 38
34 S CANNER AND C ABLE T ERMINATION S Figure 16. MS5145-00 Laser Emulation Pin Function 1 Ground 2 RS23 2 Transmit Output 3 RS23 2 Receive Input 4 Flip Sense/Start of Scan Output 5 Proximity Detect/ Trigger Emulation Output 6 Scan/Las er Enable Input 7 Reserved 8 Data Out 9 +5VDC 10 Shield Ground MS5145-9 OCIA MS5145 Full S peed (-40) and Low Speed[...]
-
Page 39
35 S CANNER AND C ABLE T ERMINATION S Cable Connector Configurations RS232 PowerLink Cable, 55-55000 x -3 Pin Func tion 1 Shield Ground 2 RS23 2 Transmit Output 3 RS23 2 Receive Input 4 DT R Input/Light Pen Source 5 Po wer/Signal Ground 6 Light Pen Data (DSR Out for -14 interfaces) 7 CTS Input 8 RTS Output 9 +5VDC 9-Pin D-Type Connector Stand Alone[...]
-
Page 40
36 S CANNER AND C ABLE T ERMINATION S Cable Connector Configuration Keyboard Wedge Po werLink Cable 55-55002A-3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC 5-Pin DIN, Female Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect 6-Pin DIN, Male Metrologic will supply an a[...]
-
Page 41
37 R EGULATORY C OMPLIAN CE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adj ustments or perfo rmance of procedure s other than those specified herein may res ult in hazardous lase r light ex posure. Und e r no circ umstances sh ould the customer attempt t[...]
-
Page 42
38 R EGULATORY C OMPLIAN CE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class A Devices The follo w ing is applicab le when th e scanner c able is gre ater in le[...]
-
Page 43
39 R EGULATORY C OMPLIAN CE EMC Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable when th e scanner cable is less tha n 3 meters (9.8 feet) in leng th when full y extended: Les instructions ci-de ssous s’a[...]
-
Page 44
40 L IMITED W ARRANTY The MS5145 Eclipse ™ scanner s are manufactured by Metrologic at its S uzhou, China facility. The MS5145 Eclipse scanners hav e a three (3) year limited warranty from the date of manufacture. Metrologic warrants and repre sents that all MS5145 E c lipse scanners are free of all defects in ma terial, workmanship and d esign, [...]
-
Page 45
41 P ATENTS This METROLOGIC product may be covered by, but is not limited to, one or more of the following U.S. Patents: U.S. Patent No.; 5,216,232; 5,260,553; 5,340, 971; 5,424,525; 5,484,992; 5,525,789; 5,528 ,024; 5,616,908; 5,627,359; 5,661, 292; 5,777,3 15; 5,789,730; 5,789, 731; 5,811 ,780; 5,828,048; 5,925,870; 6, 029,894; 6,20 9,789; 6,227,[...]
-
Page 46
42 I NDEX A AC .................................. see power accessories ............................... 2, 3 aperture ......................................... 4 B beeper ......................... see indicator button ...................................... 4, 12 C cable .................... 20–21, 36, 33–36 communication .. 2, 3, 6, 7–11, 22,[...]
-
Page 47
43 I NDEX P parameter .............................. 27–31 power......................... 2, 3, 7, 24, 32 PowerLink........................ see cable R razzberry tone ............................. 28 red ............................... see indicator RMA ............................................ 40 RS232 ........................ see interface S[...]
-